Sonographic features of benign thyroid nodules

Interobserver reliability and overlap with malignancy

Jeffrey R. Wienke, Wui K. Chong, Julia R. Fielding, Kelly H. Zou, Carol A. Mittelstaedt

Research output: Contribution to journalArticle

169 Citations (Scopus)

Abstract

Objective. To prospectively determine the sonographic findings of nodular hyperplasia of the thyroid, to compare these with reported findings associated with malignancy, and to assess interobserver reliability. Methods. Seventy thyroid nodules were scanned, and then biopsies of the nodules were performed under sonographic guidance with fine-needle cytologic analysis; in all cases images were reviewed by 2 experienced radiologists without knowledge of clinical outcome. Findings reported associated with malignancy were specifically assessed. Interobserver agreement between the expert and secondary readers for each finding was calculated by the κ or weighted κ statistic and the Fisher exact test of independence. Results. There were 68 benign and 2 malignant nodules in a population of 63 female and 7 male patients. The mean benign nodule size was 2.9 cm; 60% were solid; 54% were hypoechoic; 59% were microlobulated or macrolobulated; 47% had central vascularity; 24% contained calcifications; and 82% were elliptical in shape. There was very good interobserver reliability for the presence of calcium (κ = 0.91) and good agreement for the presence and location of vascularity (κ = 0.75) and the amount of cystic components (κ = 0.62; all P < .01). Conclusions. Sixty-nine percent of benign nodules had at least 1 finding reported previously as associated with malignancy. The interobserver reliability of the sonographic findings was good to very good for 3 of the 5 findings assessed.

Original languageEnglish (US)
Pages (from-to)1027-1031
Number of pages5
JournalJournal of Ultrasound in Medicine
Volume22
Issue number10
StatePublished - Oct 1 2003

Fingerprint

Thyroid Nodule
Neoplasms
Needles
Hyperplasia
Thyroid Gland
Calcium
Biopsy
Population

Keywords

  • Interobserver reliability
  • Thyroid nodules
  • Thyroid sonography

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this

Sonographic features of benign thyroid nodules : Interobserver reliability and overlap with malignancy. / Wienke, Jeffrey R.; Chong, Wui K.; Fielding, Julia R.; Zou, Kelly H.; Mittelstaedt, Carol A.

In: Journal of Ultrasound in Medicine, Vol. 22, No. 10, 01.10.2003, p. 1027-1031.

Research output: Contribution to journalArticle

Wienke, Jeffrey R. ; Chong, Wui K. ; Fielding, Julia R. ; Zou, Kelly H. ; Mittelstaedt, Carol A. / Sonographic features of benign thyroid nodules : Interobserver reliability and overlap with malignancy. In: Journal of Ultrasound in Medicine. 2003 ; Vol. 22, No. 10. pp. 1027-1031.
@article{a578bebc85814d9eb56caab372cbbbe6,
title = "Sonographic features of benign thyroid nodules: Interobserver reliability and overlap with malignancy",
abstract = "Objective. To prospectively determine the sonographic findings of nodular hyperplasia of the thyroid, to compare these with reported findings associated with malignancy, and to assess interobserver reliability. Methods. Seventy thyroid nodules were scanned, and then biopsies of the nodules were performed under sonographic guidance with fine-needle cytologic analysis; in all cases images were reviewed by 2 experienced radiologists without knowledge of clinical outcome. Findings reported associated with malignancy were specifically assessed. Interobserver agreement between the expert and secondary readers for each finding was calculated by the κ or weighted κ statistic and the Fisher exact test of independence. Results. There were 68 benign and 2 malignant nodules in a population of 63 female and 7 male patients. The mean benign nodule size was 2.9 cm; 60{\%} were solid; 54{\%} were hypoechoic; 59{\%} were microlobulated or macrolobulated; 47{\%} had central vascularity; 24{\%} contained calcifications; and 82{\%} were elliptical in shape. There was very good interobserver reliability for the presence of calcium (κ = 0.91) and good agreement for the presence and location of vascularity (κ = 0.75) and the amount of cystic components (κ = 0.62; all P < .01). Conclusions. Sixty-nine percent of benign nodules had at least 1 finding reported previously as associated with malignancy. The interobserver reliability of the sonographic findings was good to very good for 3 of the 5 findings assessed.",
keywords = "Interobserver reliability, Thyroid nodules, Thyroid sonography",
author = "Wienke, {Jeffrey R.} and Chong, {Wui K.} and Fielding, {Julia R.} and Zou, {Kelly H.} and Mittelstaedt, {Carol A.}",
year = "2003",
month = "10",
day = "1",
language = "English (US)",
volume = "22",
pages = "1027--1031",
journal = "Journal of Ultrasound in Medicine",
issn = "0278-4297",
publisher = "American Institute of Ultrasound in Medicine",
number = "10",

}

TY - JOUR

T1 - Sonographic features of benign thyroid nodules

T2 - Interobserver reliability and overlap with malignancy

AU - Wienke, Jeffrey R.

AU - Chong, Wui K.

AU - Fielding, Julia R.

AU - Zou, Kelly H.

AU - Mittelstaedt, Carol A.

PY - 2003/10/1

Y1 - 2003/10/1

N2 - Objective. To prospectively determine the sonographic findings of nodular hyperplasia of the thyroid, to compare these with reported findings associated with malignancy, and to assess interobserver reliability. Methods. Seventy thyroid nodules were scanned, and then biopsies of the nodules were performed under sonographic guidance with fine-needle cytologic analysis; in all cases images were reviewed by 2 experienced radiologists without knowledge of clinical outcome. Findings reported associated with malignancy were specifically assessed. Interobserver agreement between the expert and secondary readers for each finding was calculated by the κ or weighted κ statistic and the Fisher exact test of independence. Results. There were 68 benign and 2 malignant nodules in a population of 63 female and 7 male patients. The mean benign nodule size was 2.9 cm; 60% were solid; 54% were hypoechoic; 59% were microlobulated or macrolobulated; 47% had central vascularity; 24% contained calcifications; and 82% were elliptical in shape. There was very good interobserver reliability for the presence of calcium (κ = 0.91) and good agreement for the presence and location of vascularity (κ = 0.75) and the amount of cystic components (κ = 0.62; all P < .01). Conclusions. Sixty-nine percent of benign nodules had at least 1 finding reported previously as associated with malignancy. The interobserver reliability of the sonographic findings was good to very good for 3 of the 5 findings assessed.

AB - Objective. To prospectively determine the sonographic findings of nodular hyperplasia of the thyroid, to compare these with reported findings associated with malignancy, and to assess interobserver reliability. Methods. Seventy thyroid nodules were scanned, and then biopsies of the nodules were performed under sonographic guidance with fine-needle cytologic analysis; in all cases images were reviewed by 2 experienced radiologists without knowledge of clinical outcome. Findings reported associated with malignancy were specifically assessed. Interobserver agreement between the expert and secondary readers for each finding was calculated by the κ or weighted κ statistic and the Fisher exact test of independence. Results. There were 68 benign and 2 malignant nodules in a population of 63 female and 7 male patients. The mean benign nodule size was 2.9 cm; 60% were solid; 54% were hypoechoic; 59% were microlobulated or macrolobulated; 47% had central vascularity; 24% contained calcifications; and 82% were elliptical in shape. There was very good interobserver reliability for the presence of calcium (κ = 0.91) and good agreement for the presence and location of vascularity (κ = 0.75) and the amount of cystic components (κ = 0.62; all P < .01). Conclusions. Sixty-nine percent of benign nodules had at least 1 finding reported previously as associated with malignancy. The interobserver reliability of the sonographic findings was good to very good for 3 of the 5 findings assessed.

KW - Interobserver reliability

KW - Thyroid nodules

KW - Thyroid sonography

UR - http://www.scopus.com/inward/record.url?scp=0141752907&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141752907&partnerID=8YFLogxK

M3 - Article

VL - 22

SP - 1027

EP - 1031

JO - Journal of Ultrasound in Medicine

JF - Journal of Ultrasound in Medicine

SN - 0278-4297

IS - 10

ER -