Spatial and temporal registration of cardiac SPECT and MR images

Methods and evaluation

Tracy L. Faber, Roderick W McColl, Roger M. Opperman, James R. Corbett, Ronald M Peshock

Research output: Contribution to journalArticle

51 Citations (Scopus)

Abstract

Image registration may assist in the integration of information from multiple sources by allowing direct point-for-point comparisons of studies. To determine the usefulness of such a technique, a method for the spatial and temporal registration of four-dimensional single photon emission computed tomographic (SPECT) and magnetic resonance (MR) cardiac images was developed. Automatically detected left ventricular endocardial surfaces were used to determine the best transform between the two sets of surface points, and that transform was applied to the original SPECT image. A fused image created from the MR and the transformed SPECT images combined the information in both. The authors tested the method with seven patient studies. Registration reduced the distance between the MR and SPECT left ventricular endocardial surfaces by 30%, to an average of 2.7 mm. The authors found that, by using the fused images, perfusion abnormalities could be easily localized and correlated to high-resolution endocardial wall motion and systolic wall thickening.

Original languageEnglish (US)
Pages (from-to)857-861
Number of pages5
JournalRadiology
Volume179
Issue number3
StatePublished - Jun 1991

Fingerprint

Photons
Magnetic Resonance Spectroscopy
Perfusion

Keywords

  • Emission CT, 524.129
  • Heart, MR studies, 524.1214
  • Heart, radionuclide studies, 524.129
  • Images, analysis
  • Images, display
  • Magnetic resonance (MR), image processing

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Spatial and temporal registration of cardiac SPECT and MR images : Methods and evaluation. / Faber, Tracy L.; McColl, Roderick W; Opperman, Roger M.; Corbett, James R.; Peshock, Ronald M.

In: Radiology, Vol. 179, No. 3, 06.1991, p. 857-861.

Research output: Contribution to journalArticle

Faber, Tracy L. ; McColl, Roderick W ; Opperman, Roger M. ; Corbett, James R. ; Peshock, Ronald M. / Spatial and temporal registration of cardiac SPECT and MR images : Methods and evaluation. In: Radiology. 1991 ; Vol. 179, No. 3. pp. 857-861.
@article{69061e20ca3a44f283f90c7b4c23c247,
title = "Spatial and temporal registration of cardiac SPECT and MR images: Methods and evaluation",
abstract = "Image registration may assist in the integration of information from multiple sources by allowing direct point-for-point comparisons of studies. To determine the usefulness of such a technique, a method for the spatial and temporal registration of four-dimensional single photon emission computed tomographic (SPECT) and magnetic resonance (MR) cardiac images was developed. Automatically detected left ventricular endocardial surfaces were used to determine the best transform between the two sets of surface points, and that transform was applied to the original SPECT image. A fused image created from the MR and the transformed SPECT images combined the information in both. The authors tested the method with seven patient studies. Registration reduced the distance between the MR and SPECT left ventricular endocardial surfaces by 30{\%}, to an average of 2.7 mm. The authors found that, by using the fused images, perfusion abnormalities could be easily localized and correlated to high-resolution endocardial wall motion and systolic wall thickening.",
keywords = "Emission CT, 524.129, Heart, MR studies, 524.1214, Heart, radionuclide studies, 524.129, Images, analysis, Images, display, Magnetic resonance (MR), image processing",
author = "Faber, {Tracy L.} and McColl, {Roderick W} and Opperman, {Roger M.} and Corbett, {James R.} and Peshock, {Ronald M}",
year = "1991",
month = "6",
language = "English (US)",
volume = "179",
pages = "857--861",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "3",

}

TY - JOUR

T1 - Spatial and temporal registration of cardiac SPECT and MR images

T2 - Methods and evaluation

AU - Faber, Tracy L.

AU - McColl, Roderick W

AU - Opperman, Roger M.

AU - Corbett, James R.

AU - Peshock, Ronald M

PY - 1991/6

Y1 - 1991/6

N2 - Image registration may assist in the integration of information from multiple sources by allowing direct point-for-point comparisons of studies. To determine the usefulness of such a technique, a method for the spatial and temporal registration of four-dimensional single photon emission computed tomographic (SPECT) and magnetic resonance (MR) cardiac images was developed. Automatically detected left ventricular endocardial surfaces were used to determine the best transform between the two sets of surface points, and that transform was applied to the original SPECT image. A fused image created from the MR and the transformed SPECT images combined the information in both. The authors tested the method with seven patient studies. Registration reduced the distance between the MR and SPECT left ventricular endocardial surfaces by 30%, to an average of 2.7 mm. The authors found that, by using the fused images, perfusion abnormalities could be easily localized and correlated to high-resolution endocardial wall motion and systolic wall thickening.

AB - Image registration may assist in the integration of information from multiple sources by allowing direct point-for-point comparisons of studies. To determine the usefulness of such a technique, a method for the spatial and temporal registration of four-dimensional single photon emission computed tomographic (SPECT) and magnetic resonance (MR) cardiac images was developed. Automatically detected left ventricular endocardial surfaces were used to determine the best transform between the two sets of surface points, and that transform was applied to the original SPECT image. A fused image created from the MR and the transformed SPECT images combined the information in both. The authors tested the method with seven patient studies. Registration reduced the distance between the MR and SPECT left ventricular endocardial surfaces by 30%, to an average of 2.7 mm. The authors found that, by using the fused images, perfusion abnormalities could be easily localized and correlated to high-resolution endocardial wall motion and systolic wall thickening.

KW - Emission CT, 524.129

KW - Heart, MR studies, 524.1214

KW - Heart, radionuclide studies, 524.129

KW - Images, analysis

KW - Images, display

KW - Magnetic resonance (MR), image processing

UR - http://www.scopus.com/inward/record.url?scp=0025876988&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025876988&partnerID=8YFLogxK

M3 - Article

VL - 179

SP - 857

EP - 861

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 3

ER -