Subchondral defects in caprine femora augmented with in situ setting hydroxyapatite cement, polymethylmethacrylate, or autogenous bone graft: Biomechanical and histomorphological analysis after two-years

Robert D. Welch, B. Hudson Berry, Kevin Crawford, Hong Zhang, Mark Zobitz, Dwight Bronson, Sumant Krishnan

Research output: Contribution to journalArticle

44 Citations (Scopus)

Abstract

Juxta-articular defects pose significant challenges due to the high risk of fracture of the subchondral plate and articular cartilage. We evaluated the mechanical and histomorphological repair process of caprine subchondral femoral defects augmented with either a bioresorbable in situ setting hydroxyapatite cement (HAC), polymethylmethacrylate (PMMA), autogenous bone graft (AG), or left empty. Twelve-mm subchondral defects were made bilaterally in the medial femoral condyles of skeletally mature goats and augmented with a test material or left empty. Femurs were harvested at varying time periods out to 2 years and evaluated for subchondral stiffness and histomorphological indices. Several defects augmented using autograft or left empty sustained focal fracture of the subchondral plate. No HAC or PMMA augmented defects showed evidence of subchondral fracture. The HAC and PMMA augmented defects showed comparable stiffness at all time points. The mean volume fraction of HAC remaining within the defects progressively decreased from 96% at 24 h to 38% at 2 years. The new bone replacing the HAC appeared to have normal physiological architecture and orientation. In situ setting hydroxyapatite cement may be a viable alternative for the repair of subchondral defects with an important advantage that while undergoing gradual resorption and replacement with host bone, mechanical integrity of the skeletal defect is maintained.

Original languageEnglish (US)
Pages (from-to)464-472
Number of pages9
JournalJournal of Orthopaedic Research
Volume20
Issue number3
DOIs
StatePublished - 2002

Fingerprint

Polymethyl Methacrylate
Femur
Transplants
Bone and Bones
Thigh
Autografts
Articular Cartilage
Goats
hydroxyapatite cement
Joints

Keywords

  • Bone defect
  • Bone graft
  • Bone substitute
  • Histomorphometry
  • Polymethylmethacrylate

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Subchondral defects in caprine femora augmented with in situ setting hydroxyapatite cement, polymethylmethacrylate, or autogenous bone graft : Biomechanical and histomorphological analysis after two-years. / Welch, Robert D.; Hudson Berry, B.; Crawford, Kevin; Zhang, Hong; Zobitz, Mark; Bronson, Dwight; Krishnan, Sumant.

In: Journal of Orthopaedic Research, Vol. 20, No. 3, 2002, p. 464-472.

Research output: Contribution to journalArticle

@article{552a1b1f2e6e46a4a41f1ca0601152d4,
title = "Subchondral defects in caprine femora augmented with in situ setting hydroxyapatite cement, polymethylmethacrylate, or autogenous bone graft: Biomechanical and histomorphological analysis after two-years",
abstract = "Juxta-articular defects pose significant challenges due to the high risk of fracture of the subchondral plate and articular cartilage. We evaluated the mechanical and histomorphological repair process of caprine subchondral femoral defects augmented with either a bioresorbable in situ setting hydroxyapatite cement (HAC), polymethylmethacrylate (PMMA), autogenous bone graft (AG), or left empty. Twelve-mm subchondral defects were made bilaterally in the medial femoral condyles of skeletally mature goats and augmented with a test material or left empty. Femurs were harvested at varying time periods out to 2 years and evaluated for subchondral stiffness and histomorphological indices. Several defects augmented using autograft or left empty sustained focal fracture of the subchondral plate. No HAC or PMMA augmented defects showed evidence of subchondral fracture. The HAC and PMMA augmented defects showed comparable stiffness at all time points. The mean volume fraction of HAC remaining within the defects progressively decreased from 96{\%} at 24 h to 38{\%} at 2 years. The new bone replacing the HAC appeared to have normal physiological architecture and orientation. In situ setting hydroxyapatite cement may be a viable alternative for the repair of subchondral defects with an important advantage that while undergoing gradual resorption and replacement with host bone, mechanical integrity of the skeletal defect is maintained.",
keywords = "Bone defect, Bone graft, Bone substitute, Histomorphometry, Polymethylmethacrylate",
author = "Welch, {Robert D.} and {Hudson Berry}, B. and Kevin Crawford and Hong Zhang and Mark Zobitz and Dwight Bronson and Sumant Krishnan",
year = "2002",
doi = "10.1016/S0736-0266(01)00124-3",
language = "English (US)",
volume = "20",
pages = "464--472",
journal = "Journal of Orthopaedic Research",
issn = "0736-0266",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Subchondral defects in caprine femora augmented with in situ setting hydroxyapatite cement, polymethylmethacrylate, or autogenous bone graft

T2 - Biomechanical and histomorphological analysis after two-years

AU - Welch, Robert D.

AU - Hudson Berry, B.

AU - Crawford, Kevin

AU - Zhang, Hong

AU - Zobitz, Mark

AU - Bronson, Dwight

AU - Krishnan, Sumant

PY - 2002

Y1 - 2002

N2 - Juxta-articular defects pose significant challenges due to the high risk of fracture of the subchondral plate and articular cartilage. We evaluated the mechanical and histomorphological repair process of caprine subchondral femoral defects augmented with either a bioresorbable in situ setting hydroxyapatite cement (HAC), polymethylmethacrylate (PMMA), autogenous bone graft (AG), or left empty. Twelve-mm subchondral defects were made bilaterally in the medial femoral condyles of skeletally mature goats and augmented with a test material or left empty. Femurs were harvested at varying time periods out to 2 years and evaluated for subchondral stiffness and histomorphological indices. Several defects augmented using autograft or left empty sustained focal fracture of the subchondral plate. No HAC or PMMA augmented defects showed evidence of subchondral fracture. The HAC and PMMA augmented defects showed comparable stiffness at all time points. The mean volume fraction of HAC remaining within the defects progressively decreased from 96% at 24 h to 38% at 2 years. The new bone replacing the HAC appeared to have normal physiological architecture and orientation. In situ setting hydroxyapatite cement may be a viable alternative for the repair of subchondral defects with an important advantage that while undergoing gradual resorption and replacement with host bone, mechanical integrity of the skeletal defect is maintained.

AB - Juxta-articular defects pose significant challenges due to the high risk of fracture of the subchondral plate and articular cartilage. We evaluated the mechanical and histomorphological repair process of caprine subchondral femoral defects augmented with either a bioresorbable in situ setting hydroxyapatite cement (HAC), polymethylmethacrylate (PMMA), autogenous bone graft (AG), or left empty. Twelve-mm subchondral defects were made bilaterally in the medial femoral condyles of skeletally mature goats and augmented with a test material or left empty. Femurs were harvested at varying time periods out to 2 years and evaluated for subchondral stiffness and histomorphological indices. Several defects augmented using autograft or left empty sustained focal fracture of the subchondral plate. No HAC or PMMA augmented defects showed evidence of subchondral fracture. The HAC and PMMA augmented defects showed comparable stiffness at all time points. The mean volume fraction of HAC remaining within the defects progressively decreased from 96% at 24 h to 38% at 2 years. The new bone replacing the HAC appeared to have normal physiological architecture and orientation. In situ setting hydroxyapatite cement may be a viable alternative for the repair of subchondral defects with an important advantage that while undergoing gradual resorption and replacement with host bone, mechanical integrity of the skeletal defect is maintained.

KW - Bone defect

KW - Bone graft

KW - Bone substitute

KW - Histomorphometry

KW - Polymethylmethacrylate

UR - http://www.scopus.com/inward/record.url?scp=0036238556&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036238556&partnerID=8YFLogxK

U2 - 10.1016/S0736-0266(01)00124-3

DO - 10.1016/S0736-0266(01)00124-3

M3 - Article

C2 - 12038619

AN - SCOPUS:0036238556

VL - 20

SP - 464

EP - 472

JO - Journal of Orthopaedic Research

JF - Journal of Orthopaedic Research

SN - 0736-0266

IS - 3

ER -