SU‐E‐T‐803: Dosimetric Evaluation for Pulsed Low Dose Rate Radiation Therapy Using RapidArc Delivery Techniques

C. ma, M. Lin, L. Wang, R. Price

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Purpose: There has been no consensus standard of care to treat recurrent cancer patients who have previously been irradiated. Pulsed low dose rate (PLDR) radiotherapy has potential to reduce normal tissue toxicities while still providing significant tumor control for recurrent cancers. This work investigates the dosimetry feasibility of PLDR radiotherapy using the RapidArc delivery technique for a dose escalation trial. Methods: Five body sites were investigated including breast, pancreas, prostate, head and neck, and lung. RapidArc plans were generated using the Varian Eclipse system with 6, 10 and 15MV beams. Each plan consisted of two arcs and the plan was delivered 5 times to achieve a daily dose of 2Gy. The dosimetry requirement was to deliver 20cGy/arc with a 3min interval to achieve an effective dose rate of 6.7cGy/min. Monte Carlo simulations were performed to calculate the actual dose delivered to the planning target volume (PTV) considering beam attenuation/scattering and intensity modulation. The maximum, minimum and mean doses to the PTV were analyzed together with the dose volume histograms and isodose distributions. Results: Two full arcs were necessary to achieve superior dose distributions for complex recurrent cancers to spare critical structures effectively. For 9 patients, the mean PTV dose for each arc ranged 18.9–22.6cGy/arc. For breast the minimal and the maximal PTV dose was 8.56 and 31.2cGy/arc, respectively. The RapidArc dose varied between 12.9 and 27.5cGy/arc for pancreas, 12.6 and 28.3cGy/arc for prostate, 12.1 and 30.4cGy/arc for H&N, and 16.2 and 27.6cGy/arc for lung, respectively. Good agreement was achieved between the planned doses and Matrix measurements with 95–98% passing rates Conclusions: Advanced image‐guided radiotherapy can provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent cancers, which can be delivered using the RapidArc technique with 10 full arcs and an effective dose rate of 3–10cGy/min.

Original languageEnglish (US)
Pages (from-to)3675-3676
Number of pages2
JournalMedical physics
Volume38
Issue number6
DOIs
StatePublished - Jun 2011

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'SU‐E‐T‐803: Dosimetric Evaluation for Pulsed Low Dose Rate Radiation Therapy Using RapidArc Delivery Techniques'. Together they form a unique fingerprint.

Cite this