SU‐FF‐T‐307: Monte Carlo Modeling of Variable‐Aperture Collimator for Small Animal Radiation Therapy

H. Zhou, A. Sawant, P. Keall, E. Graves

Research output: Contribution to journalArticle

Abstract

Purpose: Monte Carlo simulations have been performed to model the beam profiles produced by a two‐stage variable‐aperture collimator installed in a 120 kVp microCT scanner. These simulations will be employed as source models for further Monte Carlo calculation of dose deposition in small animals treated with image‐guided radiotherapy. Method and Materials: The EGS software package (http://www.irs.inms.nrc.ca/EGSnrc/EGSnrc.html) was used as the simulation engine. A standard spectrum for a 120 kV x‐ray tube as well as the microCT source‐collimator geometry was applied in the calculation. The radiation flux passing through the microCT isocenter plane was compared with experimental data acquired with the collimator set to corresponding aperture sizes. Results: A Monte Carlo computation considering 108 photons from a 120 kVp x‐ray completed in 3 minutes on a 2 GHz computer. A point source model showed that the two stages of 0.97‐cm brass collimator blocks create >99% attenuation, suitable for radiotherapy, with the expected dodecagonal beam profile observed at isocenter. These results were confirmed by direct measurement. A point source model however predicts only 1/3 of the penumbra width in the acquired image. A more sophisticated model considering the 0.3‐mm focal spot size of the x‐ray tube produced beam penumbras that agreed with measurement. In this model for a 1 cm aperture, 0.85% of the total fllux is from scattering, and 70% of the scattering is from the spot area outside the 0.3‐mm diameter. Conclusion: Monte Carlo simulation using the EGS software package can model a collimated kV x‐ray system including the x‐ray source and a newly developed two‐stage variable‐aperture collimator. In a reasonable computation time this model provides an accurate estimate of the output of the system that will be critical in performing dosimetric calculations and further developing the functionality of this small animal radiotherapy system.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume34
Issue number6
DOIs
StatePublished - 2007

Fingerprint

Radiotherapy
X-Ray Microtomography
X-Rays
Software
Photons
Radiation

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐FF‐T‐307 : Monte Carlo Modeling of Variable‐Aperture Collimator for Small Animal Radiation Therapy. / Zhou, H.; Sawant, A.; Keall, P.; Graves, E.

In: Medical Physics, Vol. 34, No. 6, 2007.

Research output: Contribution to journalArticle

@article{cccd1d2afbaf49f3811cf7c025b01c74,
title = "SU‐FF‐T‐307: Monte Carlo Modeling of Variable‐Aperture Collimator for Small Animal Radiation Therapy",
abstract = "Purpose: Monte Carlo simulations have been performed to model the beam profiles produced by a two‐stage variable‐aperture collimator installed in a 120 kVp microCT scanner. These simulations will be employed as source models for further Monte Carlo calculation of dose deposition in small animals treated with image‐guided radiotherapy. Method and Materials: The EGS software package (http://www.irs.inms.nrc.ca/EGSnrc/EGSnrc.html) was used as the simulation engine. A standard spectrum for a 120 kV x‐ray tube as well as the microCT source‐collimator geometry was applied in the calculation. The radiation flux passing through the microCT isocenter plane was compared with experimental data acquired with the collimator set to corresponding aperture sizes. Results: A Monte Carlo computation considering 108 photons from a 120 kVp x‐ray completed in 3 minutes on a 2 GHz computer. A point source model showed that the two stages of 0.97‐cm brass collimator blocks create >99{\%} attenuation, suitable for radiotherapy, with the expected dodecagonal beam profile observed at isocenter. These results were confirmed by direct measurement. A point source model however predicts only 1/3 of the penumbra width in the acquired image. A more sophisticated model considering the 0.3‐mm focal spot size of the x‐ray tube produced beam penumbras that agreed with measurement. In this model for a 1 cm aperture, 0.85{\%} of the total fllux is from scattering, and 70{\%} of the scattering is from the spot area outside the 0.3‐mm diameter. Conclusion: Monte Carlo simulation using the EGS software package can model a collimated kV x‐ray system including the x‐ray source and a newly developed two‐stage variable‐aperture collimator. In a reasonable computation time this model provides an accurate estimate of the output of the system that will be critical in performing dosimetric calculations and further developing the functionality of this small animal radiotherapy system.",
author = "H. Zhou and A. Sawant and P. Keall and E. Graves",
year = "2007",
doi = "10.1118/1.2760969",
language = "English (US)",
volume = "34",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐FF‐T‐307

T2 - Monte Carlo Modeling of Variable‐Aperture Collimator for Small Animal Radiation Therapy

AU - Zhou, H.

AU - Sawant, A.

AU - Keall, P.

AU - Graves, E.

PY - 2007

Y1 - 2007

N2 - Purpose: Monte Carlo simulations have been performed to model the beam profiles produced by a two‐stage variable‐aperture collimator installed in a 120 kVp microCT scanner. These simulations will be employed as source models for further Monte Carlo calculation of dose deposition in small animals treated with image‐guided radiotherapy. Method and Materials: The EGS software package (http://www.irs.inms.nrc.ca/EGSnrc/EGSnrc.html) was used as the simulation engine. A standard spectrum for a 120 kV x‐ray tube as well as the microCT source‐collimator geometry was applied in the calculation. The radiation flux passing through the microCT isocenter plane was compared with experimental data acquired with the collimator set to corresponding aperture sizes. Results: A Monte Carlo computation considering 108 photons from a 120 kVp x‐ray completed in 3 minutes on a 2 GHz computer. A point source model showed that the two stages of 0.97‐cm brass collimator blocks create >99% attenuation, suitable for radiotherapy, with the expected dodecagonal beam profile observed at isocenter. These results were confirmed by direct measurement. A point source model however predicts only 1/3 of the penumbra width in the acquired image. A more sophisticated model considering the 0.3‐mm focal spot size of the x‐ray tube produced beam penumbras that agreed with measurement. In this model for a 1 cm aperture, 0.85% of the total fllux is from scattering, and 70% of the scattering is from the spot area outside the 0.3‐mm diameter. Conclusion: Monte Carlo simulation using the EGS software package can model a collimated kV x‐ray system including the x‐ray source and a newly developed two‐stage variable‐aperture collimator. In a reasonable computation time this model provides an accurate estimate of the output of the system that will be critical in performing dosimetric calculations and further developing the functionality of this small animal radiotherapy system.

AB - Purpose: Monte Carlo simulations have been performed to model the beam profiles produced by a two‐stage variable‐aperture collimator installed in a 120 kVp microCT scanner. These simulations will be employed as source models for further Monte Carlo calculation of dose deposition in small animals treated with image‐guided radiotherapy. Method and Materials: The EGS software package (http://www.irs.inms.nrc.ca/EGSnrc/EGSnrc.html) was used as the simulation engine. A standard spectrum for a 120 kV x‐ray tube as well as the microCT source‐collimator geometry was applied in the calculation. The radiation flux passing through the microCT isocenter plane was compared with experimental data acquired with the collimator set to corresponding aperture sizes. Results: A Monte Carlo computation considering 108 photons from a 120 kVp x‐ray completed in 3 minutes on a 2 GHz computer. A point source model showed that the two stages of 0.97‐cm brass collimator blocks create >99% attenuation, suitable for radiotherapy, with the expected dodecagonal beam profile observed at isocenter. These results were confirmed by direct measurement. A point source model however predicts only 1/3 of the penumbra width in the acquired image. A more sophisticated model considering the 0.3‐mm focal spot size of the x‐ray tube produced beam penumbras that agreed with measurement. In this model for a 1 cm aperture, 0.85% of the total fllux is from scattering, and 70% of the scattering is from the spot area outside the 0.3‐mm diameter. Conclusion: Monte Carlo simulation using the EGS software package can model a collimated kV x‐ray system including the x‐ray source and a newly developed two‐stage variable‐aperture collimator. In a reasonable computation time this model provides an accurate estimate of the output of the system that will be critical in performing dosimetric calculations and further developing the functionality of this small animal radiotherapy system.

UR - http://www.scopus.com/inward/record.url?scp=85024774012&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024774012&partnerID=8YFLogxK

U2 - 10.1118/1.2760969

DO - 10.1118/1.2760969

M3 - Article

AN - SCOPUS:85024774012

VL - 34

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -