N2 - Background: Guidelines recommend that implantable cardioverter-defibrillator (ICD) candidates have an estimated longevity of ≥1 year. Longevity can be affected by chronic kidney disease (CKD). Methods and Results: Using the National Cardiovascular Data Registry ICD registry linked with the Social Security Death Master File, we assessed the rate of death after primary prevention ICD placement between January 1, 2006, and December 31, 2007, according to CKD stage. Using Cox models, we identified factors associated with death among patients with CKD. Compared with patients without CKD (n=26 056), those with CKD (n=21 226) were older, less commonly men, more often white, and more frequently had comorbid illness. Compared with patients without CKD, patients with a glomerular filtration rate 30 to 60, glomerular filtration rate <30, and end-stage renal disease on dialysis had a higher risk of death after ICD placement (hazard ratio, 2.08; 95% confidence interval, 1.99-2.18; P<0.0001; hazard ratio, 4.20; 95% confidence interval, 3.92-4.50; P<0.0001; and hazard ratio, 4.80; 95% confidence interval, 4.46-5.17; P<0.0001, respectively). Corresponding 1-year death rates were 4.4%, 9.1%, 20.2%, and 22.4%. Among patients with CKD, factors associated with increased risk of death included CKD severity, age >65 years, heart failure symptoms, diabetes mellitus, lung disease, serum sodium <140 mEq/L, atrial fibrillation or flutter, and a lower ejection fraction. Conclusions: The risk of death after primary prevention ICD placement is proportional to CKD severity. Among patients with CKD, several factors are prognostically significant and could inform clinical decision making on primary prevention ICD candidacy.
AB - Background: Guidelines recommend that implantable cardioverter-defibrillator (ICD) candidates have an estimated longevity of ≥1 year. Longevity can be affected by chronic kidney disease (CKD). Methods and Results: Using the National Cardiovascular Data Registry ICD registry linked with the Social Security Death Master File, we assessed the rate of death after primary prevention ICD placement between January 1, 2006, and December 31, 2007, according to CKD stage. Using Cox models, we identified factors associated with death among patients with CKD. Compared with patients without CKD (n=26 056), those with CKD (n=21 226) were older, less commonly men, more often white, and more frequently had comorbid illness. Compared with patients without CKD, patients with a glomerular filtration rate 30 to 60, glomerular filtration rate <30, and end-stage renal disease on dialysis had a higher risk of death after ICD placement (hazard ratio, 2.08; 95% confidence interval, 1.99-2.18; P<0.0001; hazard ratio, 4.20; 95% confidence interval, 3.92-4.50; P<0.0001; and hazard ratio, 4.80; 95% confidence interval, 4.46-5.17; P<0.0001, respectively). Corresponding 1-year death rates were 4.4%, 9.1%, 20.2%, and 22.4%. Among patients with CKD, factors associated with increased risk of death included CKD severity, age >65 years, heart failure symptoms, diabetes mellitus, lung disease, serum sodium <140 mEq/L, atrial fibrillation or flutter, and a lower ejection fraction. Conclusions: The risk of death after primary prevention ICD placement is proportional to CKD severity. Among patients with CKD, several factors are prognostically significant and could inform clinical decision making on primary prevention ICD candidacy.
KW - Implantable
KW - Renal insufficiency
KW - chronic
KW - defibrillators
UR - http://www.scopus.com/inward/record.url?scp=84920011661&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84920011661&partnerID=8YFLogxK
U2 - 10.1161/CIRCEP.114.001455
DO - 10.1161/CIRCEP.114.001455
M3 - Review article
C2 - 25038119
AN - SCOPUS:84920011661
SN - 1941-3149
VL - 7
SP - 793
EP - 799
JO - Circulation: Arrhythmia and Electrophysiology
JF - Circulation: Arrhythmia and Electrophysiology
IS - 5
ER -