The development of GAMMA knife treatment planning system

Y. Yan, X. Bao, Y. Bai, L. Luo, H. Shu, Z. Lu, S. Li, J. Lu, H. Hua

Research output: Contribution to journalArticle

Abstract

GAMMA-TPS was a three dimensional treatment planning system of high performance specially developed for ELEKTA's GAMMA Knife Treatment System, which had an independent image input system of Microsoft Windows' style based on personal computer (486 or higher) and multimedia card and a main planning system of X-Windows' style based on SGI INDIGO2 workstation. It worked with a nice and friendly graphical interface; could input and manage patient's details; extract external contours automatically and determine contours of target or ROIs interactively; reconsf interest within skull, at the same time of contour-drawing; determine automatically or interactively the parameters of focuses, such as number, position, collimator size, source distribution etc; make dose prescription at the point of maximum dose or at any other reference point and make out automatically the precise treatment time for each focus. To make GAMMA-TPS safer or for the sake of evaluation and scientific research, it provided the user with kinds of verification tools, such as volumetric dose distribution, Beam's Eye View, Dose-Volume Histograms, isodose contours, isodose surfaces, dose summary table, magnifier etc. As a result, it exported the treatment plan by means of laser jet printer. We presented the essential concepts of our treatment planning approach, and illustrated these in a clinical case.

Original languageEnglish (US)
JournalChinese Journal of Medical and Biological Engineering
Volume19
Issue number2
StatePublished - 1999

Fingerprint

Planning
Personal computers
Therapeutics
Multimedia
Microcomputers
Skull
Lasers
Prescriptions

Keywords

  • 3-Dimentional treatment planning
  • Computer graphics
  • Dose calculation
  • Image processing
  • Stereotactic radiosurgery

ASJC Scopus subject areas

  • Biophysics

Cite this

The development of GAMMA knife treatment planning system. / Yan, Y.; Bao, X.; Bai, Y.; Luo, L.; Shu, H.; Lu, Z.; Li, S.; Lu, J.; Hua, H.

In: Chinese Journal of Medical and Biological Engineering, Vol. 19, No. 2, 1999.

Research output: Contribution to journalArticle

Yan, Y, Bao, X, Bai, Y, Luo, L, Shu, H, Lu, Z, Li, S, Lu, J & Hua, H 1999, 'The development of GAMMA knife treatment planning system', Chinese Journal of Medical and Biological Engineering, vol. 19, no. 2.
Yan, Y. ; Bao, X. ; Bai, Y. ; Luo, L. ; Shu, H. ; Lu, Z. ; Li, S. ; Lu, J. ; Hua, H. / The development of GAMMA knife treatment planning system. In: Chinese Journal of Medical and Biological Engineering. 1999 ; Vol. 19, No. 2.
@article{988dcd6575174bcf96d4e1db15776884,
title = "The development of GAMMA knife treatment planning system",
abstract = "GAMMA-TPS was a three dimensional treatment planning system of high performance specially developed for ELEKTA's GAMMA Knife Treatment System, which had an independent image input system of Microsoft Windows' style based on personal computer (486 or higher) and multimedia card and a main planning system of X-Windows' style based on SGI INDIGO2 workstation. It worked with a nice and friendly graphical interface; could input and manage patient's details; extract external contours automatically and determine contours of target or ROIs interactively; reconsf interest within skull, at the same time of contour-drawing; determine automatically or interactively the parameters of focuses, such as number, position, collimator size, source distribution etc; make dose prescription at the point of maximum dose or at any other reference point and make out automatically the precise treatment time for each focus. To make GAMMA-TPS safer or for the sake of evaluation and scientific research, it provided the user with kinds of verification tools, such as volumetric dose distribution, Beam's Eye View, Dose-Volume Histograms, isodose contours, isodose surfaces, dose summary table, magnifier etc. As a result, it exported the treatment plan by means of laser jet printer. We presented the essential concepts of our treatment planning approach, and illustrated these in a clinical case.",
keywords = "3-Dimentional treatment planning, Computer graphics, Dose calculation, Image processing, Stereotactic radiosurgery",
author = "Y. Yan and X. Bao and Y. Bai and L. Luo and H. Shu and Z. Lu and S. Li and J. Lu and H. Hua",
year = "1999",
language = "English (US)",
volume = "19",
journal = "Journal of Medical and Biological Engineering",
issn = "1609-0985",
publisher = "Biomedical Engineering Society",
number = "2",

}

TY - JOUR

T1 - The development of GAMMA knife treatment planning system

AU - Yan, Y.

AU - Bao, X.

AU - Bai, Y.

AU - Luo, L.

AU - Shu, H.

AU - Lu, Z.

AU - Li, S.

AU - Lu, J.

AU - Hua, H.

PY - 1999

Y1 - 1999

N2 - GAMMA-TPS was a three dimensional treatment planning system of high performance specially developed for ELEKTA's GAMMA Knife Treatment System, which had an independent image input system of Microsoft Windows' style based on personal computer (486 or higher) and multimedia card and a main planning system of X-Windows' style based on SGI INDIGO2 workstation. It worked with a nice and friendly graphical interface; could input and manage patient's details; extract external contours automatically and determine contours of target or ROIs interactively; reconsf interest within skull, at the same time of contour-drawing; determine automatically or interactively the parameters of focuses, such as number, position, collimator size, source distribution etc; make dose prescription at the point of maximum dose or at any other reference point and make out automatically the precise treatment time for each focus. To make GAMMA-TPS safer or for the sake of evaluation and scientific research, it provided the user with kinds of verification tools, such as volumetric dose distribution, Beam's Eye View, Dose-Volume Histograms, isodose contours, isodose surfaces, dose summary table, magnifier etc. As a result, it exported the treatment plan by means of laser jet printer. We presented the essential concepts of our treatment planning approach, and illustrated these in a clinical case.

AB - GAMMA-TPS was a three dimensional treatment planning system of high performance specially developed for ELEKTA's GAMMA Knife Treatment System, which had an independent image input system of Microsoft Windows' style based on personal computer (486 or higher) and multimedia card and a main planning system of X-Windows' style based on SGI INDIGO2 workstation. It worked with a nice and friendly graphical interface; could input and manage patient's details; extract external contours automatically and determine contours of target or ROIs interactively; reconsf interest within skull, at the same time of contour-drawing; determine automatically or interactively the parameters of focuses, such as number, position, collimator size, source distribution etc; make dose prescription at the point of maximum dose or at any other reference point and make out automatically the precise treatment time for each focus. To make GAMMA-TPS safer or for the sake of evaluation and scientific research, it provided the user with kinds of verification tools, such as volumetric dose distribution, Beam's Eye View, Dose-Volume Histograms, isodose contours, isodose surfaces, dose summary table, magnifier etc. As a result, it exported the treatment plan by means of laser jet printer. We presented the essential concepts of our treatment planning approach, and illustrated these in a clinical case.

KW - 3-Dimentional treatment planning

KW - Computer graphics

KW - Dose calculation

KW - Image processing

KW - Stereotactic radiosurgery

UR - http://www.scopus.com/inward/record.url?scp=0032748360&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032748360&partnerID=8YFLogxK

M3 - Article

VL - 19

JO - Journal of Medical and Biological Engineering

JF - Journal of Medical and Biological Engineering

SN - 1609-0985

IS - 2

ER -