TY - JOUR
T1 - The new Petilaryngeal Airway (CobraPLA™) is as efficient as the Laryngeal Mask Airway (LMA™) but provides better airway sealing pressures
AU - Akça, Ozan
AU - Wadhwa, Anupama
AU - Sengupta, Papiya
AU - Durrani, Jaleel
AU - Hanni, Keith
AU - Wenke, Mary
AU - Yücel, Yüksel
AU - Lenhardt, Rainer
AU - Doufas, Anthony G.
AU - Sessler, Daniel I.
PY - 2004/7
Y1 - 2004/7
N2 - The Laryngeal Mask Airway (LMA) is a frequently used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to the LMA with regard to insertion time and airway sealing pressure and comparable to the LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl administration, 81 ASA physical status I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg IV), and the airway was inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 mL/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 mL/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired Student's t-tests, ξ2 tests, or Fisher's exact tests; P < 0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23 ± 6 cm H2O) than LMA (18 ± 5 cm H2O, P < 0.001). The CobraPLA has insertion characteristics similar to the LMA but better airway sealing capabilities.
AB - The Laryngeal Mask Airway (LMA) is a frequently used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to the LMA with regard to insertion time and airway sealing pressure and comparable to the LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl administration, 81 ASA physical status I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg IV), and the airway was inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 mL/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 mL/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired Student's t-tests, ξ2 tests, or Fisher's exact tests; P < 0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23 ± 6 cm H2O) than LMA (18 ± 5 cm H2O, P < 0.001). The CobraPLA has insertion characteristics similar to the LMA but better airway sealing capabilities.
UR - http://www.scopus.com/inward/record.url?scp=3042660598&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3042660598&partnerID=8YFLogxK
U2 - 10.1213/01.ANE.0000117003.60213.E9
DO - 10.1213/01.ANE.0000117003.60213.E9
M3 - Article
C2 - 15281543
AN - SCOPUS:3042660598
SN - 0003-2999
VL - 99
SP - 272
EP - 278
JO - Anesthesia and Analgesia
JF - Anesthesia and Analgesia
IS - 1
ER -