Abstract

Long-term follow-up of early Charnley cemented THAs demonstrates excellent survival (Table 1). New techniques in cementing have improved the quality of the femoral cement fixation and have shown consistently good performance at 10-year follow-up. Noncemented designs have not yet demonstrated similar long-term results. Recent reports reveal osteolysis in noncemented prostheses, which is observed earlier than in cemented designs. This implies a greater role for polyethylene debris in the etiology of osteolysis. Polyethylene debris is produced not only at the articulation but also at the nonarticular metal-polyethylene interface in modular metal-backed acetabular components. This results in the production of additional plastic debris. Metal backing has not demonstrated any clinical improvement in the long-term performance of cemented acetabular components. Furthermore, it may be detrimental due to decreased polyethylene thickness, increased stress within the polyethylene, and an increased rate of polyethylene wear of both the articular and nonarticular surfaces. Multiple reports have demonstrated that titanium alloy is not an acceptable articulating surface because it has a poor resistance to abrasion. It can result in severe metallosis in the periarticular tissues, leading to progressive osteolysis and early failure of the arthroplasty. Caution is suggested in the widespread application of polymodular femoral components because the production of metallic debris may prove excessive. Cemented THA remains the gold standard by which other methods of fixation must be assessed. The enviable long-term results with early cementing techniques and the Charnley prosthesis will be difficult to match, even with developing technology.

Original languageEnglish (US)
Pages (from-to)599-609
Number of pages11
JournalOrthopedic Clinics of North America
Volume24
Issue number4
StatePublished - 1993

Fingerprint

Polyethylene
Arthroplasty
Hip
Osteolysis
Tacrine
Metals
Thigh
Prostheses and Implants
Titanium
Plastics
Joints
Technology

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Evans, B. G., Salvati, E. A., Huo, M. H., & Huk, O. L. (1993). The rationale for cemented total hip arthroplasty. Orthopedic Clinics of North America, 24(4), 599-609.

The rationale for cemented total hip arthroplasty. / Evans, B. G.; Salvati, E. A.; Huo, M. H.; Huk, O. L.

In: Orthopedic Clinics of North America, Vol. 24, No. 4, 1993, p. 599-609.

Research output: Contribution to journalArticle

Evans, BG, Salvati, EA, Huo, MH & Huk, OL 1993, 'The rationale for cemented total hip arthroplasty', Orthopedic Clinics of North America, vol. 24, no. 4, pp. 599-609.
Evans, B. G. ; Salvati, E. A. ; Huo, M. H. ; Huk, O. L. / The rationale for cemented total hip arthroplasty. In: Orthopedic Clinics of North America. 1993 ; Vol. 24, No. 4. pp. 599-609.
@article{e924f76c25fe4a0d84cc90d0b1fdee16,
title = "The rationale for cemented total hip arthroplasty",
abstract = "Long-term follow-up of early Charnley cemented THAs demonstrates excellent survival (Table 1). New techniques in cementing have improved the quality of the femoral cement fixation and have shown consistently good performance at 10-year follow-up. Noncemented designs have not yet demonstrated similar long-term results. Recent reports reveal osteolysis in noncemented prostheses, which is observed earlier than in cemented designs. This implies a greater role for polyethylene debris in the etiology of osteolysis. Polyethylene debris is produced not only at the articulation but also at the nonarticular metal-polyethylene interface in modular metal-backed acetabular components. This results in the production of additional plastic debris. Metal backing has not demonstrated any clinical improvement in the long-term performance of cemented acetabular components. Furthermore, it may be detrimental due to decreased polyethylene thickness, increased stress within the polyethylene, and an increased rate of polyethylene wear of both the articular and nonarticular surfaces. Multiple reports have demonstrated that titanium alloy is not an acceptable articulating surface because it has a poor resistance to abrasion. It can result in severe metallosis in the periarticular tissues, leading to progressive osteolysis and early failure of the arthroplasty. Caution is suggested in the widespread application of polymodular femoral components because the production of metallic debris may prove excessive. Cemented THA remains the gold standard by which other methods of fixation must be assessed. The enviable long-term results with early cementing techniques and the Charnley prosthesis will be difficult to match, even with developing technology.",
author = "Evans, {B. G.} and Salvati, {E. A.} and Huo, {M. H.} and Huk, {O. L.}",
year = "1993",
language = "English (US)",
volume = "24",
pages = "599--609",
journal = "Orthopedic Clinics of North America",
issn = "0030-5898",
publisher = "W.B. Saunders Ltd",
number = "4",

}

TY - JOUR

T1 - The rationale for cemented total hip arthroplasty

AU - Evans, B. G.

AU - Salvati, E. A.

AU - Huo, M. H.

AU - Huk, O. L.

PY - 1993

Y1 - 1993

N2 - Long-term follow-up of early Charnley cemented THAs demonstrates excellent survival (Table 1). New techniques in cementing have improved the quality of the femoral cement fixation and have shown consistently good performance at 10-year follow-up. Noncemented designs have not yet demonstrated similar long-term results. Recent reports reveal osteolysis in noncemented prostheses, which is observed earlier than in cemented designs. This implies a greater role for polyethylene debris in the etiology of osteolysis. Polyethylene debris is produced not only at the articulation but also at the nonarticular metal-polyethylene interface in modular metal-backed acetabular components. This results in the production of additional plastic debris. Metal backing has not demonstrated any clinical improvement in the long-term performance of cemented acetabular components. Furthermore, it may be detrimental due to decreased polyethylene thickness, increased stress within the polyethylene, and an increased rate of polyethylene wear of both the articular and nonarticular surfaces. Multiple reports have demonstrated that titanium alloy is not an acceptable articulating surface because it has a poor resistance to abrasion. It can result in severe metallosis in the periarticular tissues, leading to progressive osteolysis and early failure of the arthroplasty. Caution is suggested in the widespread application of polymodular femoral components because the production of metallic debris may prove excessive. Cemented THA remains the gold standard by which other methods of fixation must be assessed. The enviable long-term results with early cementing techniques and the Charnley prosthesis will be difficult to match, even with developing technology.

AB - Long-term follow-up of early Charnley cemented THAs demonstrates excellent survival (Table 1). New techniques in cementing have improved the quality of the femoral cement fixation and have shown consistently good performance at 10-year follow-up. Noncemented designs have not yet demonstrated similar long-term results. Recent reports reveal osteolysis in noncemented prostheses, which is observed earlier than in cemented designs. This implies a greater role for polyethylene debris in the etiology of osteolysis. Polyethylene debris is produced not only at the articulation but also at the nonarticular metal-polyethylene interface in modular metal-backed acetabular components. This results in the production of additional plastic debris. Metal backing has not demonstrated any clinical improvement in the long-term performance of cemented acetabular components. Furthermore, it may be detrimental due to decreased polyethylene thickness, increased stress within the polyethylene, and an increased rate of polyethylene wear of both the articular and nonarticular surfaces. Multiple reports have demonstrated that titanium alloy is not an acceptable articulating surface because it has a poor resistance to abrasion. It can result in severe metallosis in the periarticular tissues, leading to progressive osteolysis and early failure of the arthroplasty. Caution is suggested in the widespread application of polymodular femoral components because the production of metallic debris may prove excessive. Cemented THA remains the gold standard by which other methods of fixation must be assessed. The enviable long-term results with early cementing techniques and the Charnley prosthesis will be difficult to match, even with developing technology.

UR - http://www.scopus.com/inward/record.url?scp=0027501541&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027501541&partnerID=8YFLogxK

M3 - Article

C2 - 8414425

AN - SCOPUS:0027501541

VL - 24

SP - 599

EP - 609

JO - Orthopedic Clinics of North America

JF - Orthopedic Clinics of North America

SN - 0030-5898

IS - 4

ER -