OBJECTIVE: Appropriate clip selection frequently becomes a matter of trial and error because of inadequate dissection of the pathway for each clip blade. To facilitate selection of the proper clip size, a series of dissectors have been designed that mimic the exact caliber of each category of Sugita clips. METHODS: Three lines of sizer-dissectors reflecting the wire size of the most commonly used Sugita clips were developed by attaching a single aneurysm clip blade to a rounded microdissector handle. Each sizer-dissector is scaled in millimeters and is available in straight and angled configurations. Once dissection is presumed to be complete, the device is passed through the pathway of the intended aneurysm clip blades, and the clip with the appropriate caliber and length for permanent occlusion is selected. RESULTS: During dissection and clip ligation of 83 aneurysms, the sizer-dissector was used to select the blade length in 16 lesions and the blade caliber in 5 lesions. There were no complications associated with deployment of the device. CONCLUSION: By use of the sizer-dissector before attempting clip placement, clip selection is facilitated, safety is enhanced, and clip wastage is reduced.

Original languageEnglish (US)
Pages (from-to)669-671
Number of pages3
JournalNeurosurgery
Volume50
Issue number3
DOIs
StatePublished - Mar 1 2002

Fingerprint

Surgical Instruments
Aneurysm
Dissection
Equipment and Supplies
Ligation
Safety

Keywords

  • Aneurysm
  • Aneurysm clip
  • Dissector

ASJC Scopus subject areas

  • Clinical Neurology
  • Surgery

Cite this

Giannotta, S. L., Solomon, R. A., Kobayashi, S., Hongo, K., Batjer, H. H., Spetzler, R. F., & Elder, W. L. (2002). The sizer-dissector for aneurysm clip selection: Technical note. Neurosurgery, 50(3), 669-671. https://doi.org/10.1097/00006123-200203000-00049

The sizer-dissector for aneurysm clip selection : Technical note. / Giannotta, Steven L.; Solomon, Robert A.; Kobayashi, Shigeaki; Hongo, Kazuhiro; Batjer, H. Hunt; Spetzler, Robert F.; Elder, Wendy L.

In: Neurosurgery, Vol. 50, No. 3, 01.03.2002, p. 669-671.

Research output: Contribution to journalArticle

Giannotta, SL, Solomon, RA, Kobayashi, S, Hongo, K, Batjer, HH, Spetzler, RF & Elder, WL 2002, 'The sizer-dissector for aneurysm clip selection: Technical note', Neurosurgery, vol. 50, no. 3, pp. 669-671. https://doi.org/10.1097/00006123-200203000-00049
Giannotta SL, Solomon RA, Kobayashi S, Hongo K, Batjer HH, Spetzler RF et al. The sizer-dissector for aneurysm clip selection: Technical note. Neurosurgery. 2002 Mar 1;50(3):669-671. https://doi.org/10.1097/00006123-200203000-00049
Giannotta, Steven L. ; Solomon, Robert A. ; Kobayashi, Shigeaki ; Hongo, Kazuhiro ; Batjer, H. Hunt ; Spetzler, Robert F. ; Elder, Wendy L. / The sizer-dissector for aneurysm clip selection : Technical note. In: Neurosurgery. 2002 ; Vol. 50, No. 3. pp. 669-671.
@article{992d1c1534184058a68a32da5c89ef1b,
title = "The sizer-dissector for aneurysm clip selection: Technical note",
abstract = "OBJECTIVE: Appropriate clip selection frequently becomes a matter of trial and error because of inadequate dissection of the pathway for each clip blade. To facilitate selection of the proper clip size, a series of dissectors have been designed that mimic the exact caliber of each category of Sugita clips. METHODS: Three lines of sizer-dissectors reflecting the wire size of the most commonly used Sugita clips were developed by attaching a single aneurysm clip blade to a rounded microdissector handle. Each sizer-dissector is scaled in millimeters and is available in straight and angled configurations. Once dissection is presumed to be complete, the device is passed through the pathway of the intended aneurysm clip blades, and the clip with the appropriate caliber and length for permanent occlusion is selected. RESULTS: During dissection and clip ligation of 83 aneurysms, the sizer-dissector was used to select the blade length in 16 lesions and the blade caliber in 5 lesions. There were no complications associated with deployment of the device. CONCLUSION: By use of the sizer-dissector before attempting clip placement, clip selection is facilitated, safety is enhanced, and clip wastage is reduced.",
keywords = "Aneurysm, Aneurysm clip, Dissector",
author = "Giannotta, {Steven L.} and Solomon, {Robert A.} and Shigeaki Kobayashi and Kazuhiro Hongo and Batjer, {H. Hunt} and Spetzler, {Robert F.} and Elder, {Wendy L.}",
year = "2002",
month = "3",
day = "1",
doi = "10.1097/00006123-200203000-00049",
language = "English (US)",
volume = "50",
pages = "669--671",
journal = "Neurosurgery",
issn = "0148-396X",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - The sizer-dissector for aneurysm clip selection

T2 - Technical note

AU - Giannotta, Steven L.

AU - Solomon, Robert A.

AU - Kobayashi, Shigeaki

AU - Hongo, Kazuhiro

AU - Batjer, H. Hunt

AU - Spetzler, Robert F.

AU - Elder, Wendy L.

PY - 2002/3/1

Y1 - 2002/3/1

N2 - OBJECTIVE: Appropriate clip selection frequently becomes a matter of trial and error because of inadequate dissection of the pathway for each clip blade. To facilitate selection of the proper clip size, a series of dissectors have been designed that mimic the exact caliber of each category of Sugita clips. METHODS: Three lines of sizer-dissectors reflecting the wire size of the most commonly used Sugita clips were developed by attaching a single aneurysm clip blade to a rounded microdissector handle. Each sizer-dissector is scaled in millimeters and is available in straight and angled configurations. Once dissection is presumed to be complete, the device is passed through the pathway of the intended aneurysm clip blades, and the clip with the appropriate caliber and length for permanent occlusion is selected. RESULTS: During dissection and clip ligation of 83 aneurysms, the sizer-dissector was used to select the blade length in 16 lesions and the blade caliber in 5 lesions. There were no complications associated with deployment of the device. CONCLUSION: By use of the sizer-dissector before attempting clip placement, clip selection is facilitated, safety is enhanced, and clip wastage is reduced.

AB - OBJECTIVE: Appropriate clip selection frequently becomes a matter of trial and error because of inadequate dissection of the pathway for each clip blade. To facilitate selection of the proper clip size, a series of dissectors have been designed that mimic the exact caliber of each category of Sugita clips. METHODS: Three lines of sizer-dissectors reflecting the wire size of the most commonly used Sugita clips were developed by attaching a single aneurysm clip blade to a rounded microdissector handle. Each sizer-dissector is scaled in millimeters and is available in straight and angled configurations. Once dissection is presumed to be complete, the device is passed through the pathway of the intended aneurysm clip blades, and the clip with the appropriate caliber and length for permanent occlusion is selected. RESULTS: During dissection and clip ligation of 83 aneurysms, the sizer-dissector was used to select the blade length in 16 lesions and the blade caliber in 5 lesions. There were no complications associated with deployment of the device. CONCLUSION: By use of the sizer-dissector before attempting clip placement, clip selection is facilitated, safety is enhanced, and clip wastage is reduced.

KW - Aneurysm

KW - Aneurysm clip

KW - Dissector

UR - http://www.scopus.com/inward/record.url?scp=0036524057&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036524057&partnerID=8YFLogxK

U2 - 10.1097/00006123-200203000-00049

DO - 10.1097/00006123-200203000-00049

M3 - Article

C2 - 11841741

AN - SCOPUS:0036524057

VL - 50

SP - 669

EP - 671

JO - Neurosurgery

JF - Neurosurgery

SN - 0148-396X

IS - 3

ER -