Toward optimization of in vivo super-resolution ultrasound imaging using size-selected microbubble contrast agents:

Debabrata Ghosh, Fangyuan Xiong, Shashank R. Sirsi, Philip W. Shaul, Robert F. Mattrey, Kenneth Hoyt

Research output: Contribution to journalArticlepeer-review

45 Scopus citations

Abstract

Purpose: Microvascular processes play key roles in many diseases including diabetes. Improved understanding of the microvascular changes involved in disease development could offer crucial insight into the relationship of these changes to disease pathogenesis. Super-resolution ultrasound (SR-US) imaging has showed the potential to visualize microvascular detail down to the capillary level (i.e., subwavelength resolution), but optimization is still necessary. The purpose of this study was to investigate in vivo SR-US imaging of skeletal muscle microvascularity using microbubble (MB) contrast agents of various size and concentration while evaluating different ultrasound (US) system level parameters such as imaging frame rate and image acquisition length. Methods: An US system equipped with a linear array transducer was used in a harmonic imaging mode at low transmit power. C57BL/6J mice fed a normal diet were used in this study. An assortment of size-selected MB contrast agents (1-2 μm, 3-4 μm, and 5-8 μm in diameter) were slowly infused in the tail vein at various doses (1.25 × 107, 2.5 × 107, or 5 × 107 MBs). US image data were collected before MB injection and thereafter for 10 min at 30 frames per s (fps). The US transducer was fixed throughout and between each imaging period to help capture microvascular patterns along the same image plane. An adaptive SR-US image processing technique was implemented using custom Matlab software. Results: Experimental findings illustrate the use of larger MB results in better SR-US images in terms of skeletal muscle microvascular detail. A dose of 2.5 × 107 MBs resulted in SR-US images with optimal spatial resolution. An US imaging rate of at least 20 fps and image acquisition length of at least 8 min also resulted in SR-US images with pronounced microvascular detail. Conclusions: This study indicates that MB size and dose and US system imaging rate and data acquisition length have significant impact on the quality of in vivo SR-US images of skeletal muscle microvascularity.

Original languageEnglish (US)
Pages (from-to)6304-6313
Number of pages10
JournalMedical physics
Volume44
Issue number12
DOIs
StatePublished - Dec 2017

Keywords

  • contrast-enhanced ultrasound
  • diabetes
  • microbubbles
  • super-resolution ultrasound

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Toward optimization of in vivo super-resolution ultrasound imaging using size-selected microbubble contrast agents:'. Together they form a unique fingerprint.

Cite this