Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI

Wen Chau Wu, Jiongjiong Wang, John A. Detre, Sarah J. Ratcliffe, Thomas F. Floyd

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Purpose: To test the hypothesis that flow measurements using continuous arterial spin labeling (CASL) magnetic resonance imaging (MRI) in muscle depend upon transit delay, and examine the repeatability of CASL measurements. Materials and Methods: A total of 23 healthy subjects underwent CASL imaging of the calf, foot, and forearm with varying postlabeling delay (PLD = 1000, 1500, and 1900 msec). Experiments were conducted on a 3.0T system. An orthopedic tourniquet system was employed to create a five-minute period of ischemia followed by a transient hyperernic flow. Imaging commenced two minutes prior to cuff inflation and ended three minutes after cuff release. Results: CASL was found able to well resolve the time course of the hyperemic flow pattern with an effective TR of 16 seconds, although we were unable to establish that a plateau had been reached in the flow measurements even at a PLD as long as 1900 msec. Peak hyperemic flow measurements compared favorably with those obtained with contrast-enhanced (CE) MRI following a similar period of ischemia. Region-of-interest (ROI)-based repeated measurements varied by approximately 20% over a period of one hour. Conclusion: In all anatomic regions studied, flow measurements were found to increase with PLD, suggesting the prolonged transit delay in muscle.

Original languageEnglish (US)
Pages (from-to)445-452
Number of pages8
JournalJournal of Magnetic Resonance Imaging
Volume28
Issue number2
DOIs
StatePublished - Aug 1 2008

Fingerprint

Magnetic Resonance Angiography
Muscles
Ischemia
Magnetic Resonance Imaging
Tourniquets
Economic Inflation
Forearm
Orthopedics
Foot
Healthy Volunteers
1-dodecylpyridoxal

Keywords

  • Blood flow
  • CASL
  • Continuous arterial spin labeling
  • Hyperemia
  • Magnetic resonance
  • Skeletal muscle
  • Transit delay

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI. / Wu, Wen Chau; Wang, Jiongjiong; Detre, John A.; Ratcliffe, Sarah J.; Floyd, Thomas F.

In: Journal of Magnetic Resonance Imaging, Vol. 28, No. 2, 01.08.2008, p. 445-452.

Research output: Contribution to journalArticle

Wu, Wen Chau ; Wang, Jiongjiong ; Detre, John A. ; Ratcliffe, Sarah J. ; Floyd, Thomas F. / Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI. In: Journal of Magnetic Resonance Imaging. 2008 ; Vol. 28, No. 2. pp. 445-452.
@article{4538bce06bae47e5a8acbe35be4c262b,
title = "Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI",
abstract = "Purpose: To test the hypothesis that flow measurements using continuous arterial spin labeling (CASL) magnetic resonance imaging (MRI) in muscle depend upon transit delay, and examine the repeatability of CASL measurements. Materials and Methods: A total of 23 healthy subjects underwent CASL imaging of the calf, foot, and forearm with varying postlabeling delay (PLD = 1000, 1500, and 1900 msec). Experiments were conducted on a 3.0T system. An orthopedic tourniquet system was employed to create a five-minute period of ischemia followed by a transient hyperernic flow. Imaging commenced two minutes prior to cuff inflation and ended three minutes after cuff release. Results: CASL was found able to well resolve the time course of the hyperemic flow pattern with an effective TR of 16 seconds, although we were unable to establish that a plateau had been reached in the flow measurements even at a PLD as long as 1900 msec. Peak hyperemic flow measurements compared favorably with those obtained with contrast-enhanced (CE) MRI following a similar period of ischemia. Region-of-interest (ROI)-based repeated measurements varied by approximately 20{\%} over a period of one hour. Conclusion: In all anatomic regions studied, flow measurements were found to increase with PLD, suggesting the prolonged transit delay in muscle.",
keywords = "Blood flow, CASL, Continuous arterial spin labeling, Hyperemia, Magnetic resonance, Skeletal muscle, Transit delay",
author = "Wu, {Wen Chau} and Jiongjiong Wang and Detre, {John A.} and Ratcliffe, {Sarah J.} and Floyd, {Thomas F.}",
year = "2008",
month = "8",
day = "1",
doi = "10.1002/jmri.21322",
language = "English (US)",
volume = "28",
pages = "445--452",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI

AU - Wu, Wen Chau

AU - Wang, Jiongjiong

AU - Detre, John A.

AU - Ratcliffe, Sarah J.

AU - Floyd, Thomas F.

PY - 2008/8/1

Y1 - 2008/8/1

N2 - Purpose: To test the hypothesis that flow measurements using continuous arterial spin labeling (CASL) magnetic resonance imaging (MRI) in muscle depend upon transit delay, and examine the repeatability of CASL measurements. Materials and Methods: A total of 23 healthy subjects underwent CASL imaging of the calf, foot, and forearm with varying postlabeling delay (PLD = 1000, 1500, and 1900 msec). Experiments were conducted on a 3.0T system. An orthopedic tourniquet system was employed to create a five-minute period of ischemia followed by a transient hyperernic flow. Imaging commenced two minutes prior to cuff inflation and ended three minutes after cuff release. Results: CASL was found able to well resolve the time course of the hyperemic flow pattern with an effective TR of 16 seconds, although we were unable to establish that a plateau had been reached in the flow measurements even at a PLD as long as 1900 msec. Peak hyperemic flow measurements compared favorably with those obtained with contrast-enhanced (CE) MRI following a similar period of ischemia. Region-of-interest (ROI)-based repeated measurements varied by approximately 20% over a period of one hour. Conclusion: In all anatomic regions studied, flow measurements were found to increase with PLD, suggesting the prolonged transit delay in muscle.

AB - Purpose: To test the hypothesis that flow measurements using continuous arterial spin labeling (CASL) magnetic resonance imaging (MRI) in muscle depend upon transit delay, and examine the repeatability of CASL measurements. Materials and Methods: A total of 23 healthy subjects underwent CASL imaging of the calf, foot, and forearm with varying postlabeling delay (PLD = 1000, 1500, and 1900 msec). Experiments were conducted on a 3.0T system. An orthopedic tourniquet system was employed to create a five-minute period of ischemia followed by a transient hyperernic flow. Imaging commenced two minutes prior to cuff inflation and ended three minutes after cuff release. Results: CASL was found able to well resolve the time course of the hyperemic flow pattern with an effective TR of 16 seconds, although we were unable to establish that a plateau had been reached in the flow measurements even at a PLD as long as 1900 msec. Peak hyperemic flow measurements compared favorably with those obtained with contrast-enhanced (CE) MRI following a similar period of ischemia. Region-of-interest (ROI)-based repeated measurements varied by approximately 20% over a period of one hour. Conclusion: In all anatomic regions studied, flow measurements were found to increase with PLD, suggesting the prolonged transit delay in muscle.

KW - Blood flow

KW - CASL

KW - Continuous arterial spin labeling

KW - Hyperemia

KW - Magnetic resonance

KW - Skeletal muscle

KW - Transit delay

UR - http://www.scopus.com/inward/record.url?scp=49049120690&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=49049120690&partnerID=8YFLogxK

U2 - 10.1002/jmri.21322

DO - 10.1002/jmri.21322

M3 - Article

C2 - 18666182

AN - SCOPUS:49049120690

VL - 28

SP - 445

EP - 452

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 2

ER -