T2-weighted 3D fast spin echo imaging with water-fat separation in a single acquisition

Ananth J. Madhuranthakam, Huanzhou Yu, Ann Shimakawa, Reed F. Busse, Martin P. Smith, Scott B. Reeder, Neil M. Rofsky, Jean H. Brittain, Charles A. McKenzie

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

Purpose: To develop a robust 3D fast spin echo (FSE) T2-weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high-quality multiplanar reformations. Materials and Methods: The Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) method was integrated with modulated refocusing flip angle 3D-FSE. Echoes required for IDEAL processing were acquired by shifting the readout gradient with respect to the Carr-Purcell-Meiboom-Gill echo. To reduce the scan time, an alternative data acquisition using two gradient echoes per repetition was implemented. Using the latter approach, a total of four gradient echoes were acquired in two repetitions and used in the modified IDEAL reconstruction. Results: 3D-FSE T2-weighted images with uniform water-fat separation were successfully acquired in various anatomies including breast, abdomen, knee, and ankle in clinically feasible scan times, ranging from 5:30-8:30 minutes. Using water-only and fat-only images, in-phase and out-of-phase images were reconstructed. Conclusion: 3D-FSE-IDEAL provides volumetric T2-weighted images with uniform water and fat separation in a single acquisition. High-resolution images with multiple contrasts can be reformatted to any orientation from a single acquisition. This could potentially replace 2D-FSE acquisitions with and without fat suppression and in multiple planes, thus improving overall imaging efficiency.

Original languageEnglish (US)
Pages (from-to)745-751
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume32
Issue number3
DOIs
StatePublished - Sep 2010

Fingerprint

Fats
Magnetic Resonance Imaging
Water
Least-Squares Analysis
Ankle
Abdomen
Knee
Anatomy
Breast

Keywords

  • 3D FSE
  • 3D T2-weighted imaging
  • Fat suppression
  • IDEAL
  • Water-fat separation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

T2-weighted 3D fast spin echo imaging with water-fat separation in a single acquisition. / Madhuranthakam, Ananth J.; Yu, Huanzhou; Shimakawa, Ann; Busse, Reed F.; Smith, Martin P.; Reeder, Scott B.; Rofsky, Neil M.; Brittain, Jean H.; McKenzie, Charles A.

In: Journal of Magnetic Resonance Imaging, Vol. 32, No. 3, 09.2010, p. 745-751.

Research output: Contribution to journalArticle

Madhuranthakam, AJ, Yu, H, Shimakawa, A, Busse, RF, Smith, MP, Reeder, SB, Rofsky, NM, Brittain, JH & McKenzie, CA 2010, 'T2-weighted 3D fast spin echo imaging with water-fat separation in a single acquisition', Journal of Magnetic Resonance Imaging, vol. 32, no. 3, pp. 745-751. https://doi.org/10.1002/jmri.22282
Madhuranthakam, Ananth J. ; Yu, Huanzhou ; Shimakawa, Ann ; Busse, Reed F. ; Smith, Martin P. ; Reeder, Scott B. ; Rofsky, Neil M. ; Brittain, Jean H. ; McKenzie, Charles A. / T2-weighted 3D fast spin echo imaging with water-fat separation in a single acquisition. In: Journal of Magnetic Resonance Imaging. 2010 ; Vol. 32, No. 3. pp. 745-751.
@article{c4ac5c63243a4c5a865fe76a37867150,
title = "T2-weighted 3D fast spin echo imaging with water-fat separation in a single acquisition",
abstract = "Purpose: To develop a robust 3D fast spin echo (FSE) T2-weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high-quality multiplanar reformations. Materials and Methods: The Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) method was integrated with modulated refocusing flip angle 3D-FSE. Echoes required for IDEAL processing were acquired by shifting the readout gradient with respect to the Carr-Purcell-Meiboom-Gill echo. To reduce the scan time, an alternative data acquisition using two gradient echoes per repetition was implemented. Using the latter approach, a total of four gradient echoes were acquired in two repetitions and used in the modified IDEAL reconstruction. Results: 3D-FSE T2-weighted images with uniform water-fat separation were successfully acquired in various anatomies including breast, abdomen, knee, and ankle in clinically feasible scan times, ranging from 5:30-8:30 minutes. Using water-only and fat-only images, in-phase and out-of-phase images were reconstructed. Conclusion: 3D-FSE-IDEAL provides volumetric T2-weighted images with uniform water and fat separation in a single acquisition. High-resolution images with multiple contrasts can be reformatted to any orientation from a single acquisition. This could potentially replace 2D-FSE acquisitions with and without fat suppression and in multiple planes, thus improving overall imaging efficiency.",
keywords = "3D FSE, 3D T2-weighted imaging, Fat suppression, IDEAL, Water-fat separation",
author = "Madhuranthakam, {Ananth J.} and Huanzhou Yu and Ann Shimakawa and Busse, {Reed F.} and Smith, {Martin P.} and Reeder, {Scott B.} and Rofsky, {Neil M.} and Brittain, {Jean H.} and McKenzie, {Charles A.}",
year = "2010",
month = "9",
doi = "10.1002/jmri.22282",
language = "English (US)",
volume = "32",
pages = "745--751",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - T2-weighted 3D fast spin echo imaging with water-fat separation in a single acquisition

AU - Madhuranthakam, Ananth J.

AU - Yu, Huanzhou

AU - Shimakawa, Ann

AU - Busse, Reed F.

AU - Smith, Martin P.

AU - Reeder, Scott B.

AU - Rofsky, Neil M.

AU - Brittain, Jean H.

AU - McKenzie, Charles A.

PY - 2010/9

Y1 - 2010/9

N2 - Purpose: To develop a robust 3D fast spin echo (FSE) T2-weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high-quality multiplanar reformations. Materials and Methods: The Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) method was integrated with modulated refocusing flip angle 3D-FSE. Echoes required for IDEAL processing were acquired by shifting the readout gradient with respect to the Carr-Purcell-Meiboom-Gill echo. To reduce the scan time, an alternative data acquisition using two gradient echoes per repetition was implemented. Using the latter approach, a total of four gradient echoes were acquired in two repetitions and used in the modified IDEAL reconstruction. Results: 3D-FSE T2-weighted images with uniform water-fat separation were successfully acquired in various anatomies including breast, abdomen, knee, and ankle in clinically feasible scan times, ranging from 5:30-8:30 minutes. Using water-only and fat-only images, in-phase and out-of-phase images were reconstructed. Conclusion: 3D-FSE-IDEAL provides volumetric T2-weighted images with uniform water and fat separation in a single acquisition. High-resolution images with multiple contrasts can be reformatted to any orientation from a single acquisition. This could potentially replace 2D-FSE acquisitions with and without fat suppression and in multiple planes, thus improving overall imaging efficiency.

AB - Purpose: To develop a robust 3D fast spin echo (FSE) T2-weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high-quality multiplanar reformations. Materials and Methods: The Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) method was integrated with modulated refocusing flip angle 3D-FSE. Echoes required for IDEAL processing were acquired by shifting the readout gradient with respect to the Carr-Purcell-Meiboom-Gill echo. To reduce the scan time, an alternative data acquisition using two gradient echoes per repetition was implemented. Using the latter approach, a total of four gradient echoes were acquired in two repetitions and used in the modified IDEAL reconstruction. Results: 3D-FSE T2-weighted images with uniform water-fat separation were successfully acquired in various anatomies including breast, abdomen, knee, and ankle in clinically feasible scan times, ranging from 5:30-8:30 minutes. Using water-only and fat-only images, in-phase and out-of-phase images were reconstructed. Conclusion: 3D-FSE-IDEAL provides volumetric T2-weighted images with uniform water and fat separation in a single acquisition. High-resolution images with multiple contrasts can be reformatted to any orientation from a single acquisition. This could potentially replace 2D-FSE acquisitions with and without fat suppression and in multiple planes, thus improving overall imaging efficiency.

KW - 3D FSE

KW - 3D T2-weighted imaging

KW - Fat suppression

KW - IDEAL

KW - Water-fat separation

UR - http://www.scopus.com/inward/record.url?scp=77956298745&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956298745&partnerID=8YFLogxK

U2 - 10.1002/jmri.22282

DO - 10.1002/jmri.22282

M3 - Article

VL - 32

SP - 745

EP - 751

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 3

ER -