Abstract

In 2005, the Joint Commission established a new reviewable Sentinel Event tied to radiation exposure. Proper identification and investigation of Sentinel Events are critical issues for maintaining Joint Commission accreditation of a hospital, mandating that the physicist correctly approach this problem. The newly defined sentinel event treats both radiotherapy and fluoroscopy, but we consider only the issues arising from the specific inclusion of prolonged fluoroscopy procedures that result in high (> 1500 rads) cumulative skin doses. The specific details of what constitutes the fluoroscopic Sentinel Event, mechanisms for detecting potential events, how to investigate an event, and what happens in the course of reviewing a Sentinel Event are addressed. The air kerma monitors required by the FDA on fluoroscopic equipment manufactured since 2006 are very useful tools for dose determination in these cases, but they do not provide a direct or complete answer. Case studies are reviewed that illustrate how to estimate doses both with and without cumulative air kerma readings. Learning Objectives: 1. Review the definitions of the new Joint Commission Sentinel Event for fluoroscopic radiation exposure. 2. Identify monitoring policies and procedures to detect potential fluoroscopic Sentinel Events. 3. Discuss practical aspects and pitfalls of using air kerma monitors and technique values to calculate maximum skin doses.

Original languageEnglish (US)
Pages (from-to)3373
Number of pages1
JournalMedical Physics
Volume37
Issue number6
DOIs
StatePublished - 2010

Fingerprint

Skin
Joints
Fluoroscopy
Air
Accreditation
cyhalothrin
Reading
Radiotherapy
Learning
Equipment and Supplies
Radiation Exposure

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

TU‐A‐202‐01 : Peak Skin Dose Reconstruction and TJC Sentinel Event. / Anderson, J.; Arbique, G.; Guild, J.

In: Medical Physics, Vol. 37, No. 6, 2010, p. 3373.

Research output: Contribution to journalArticle

@article{f45a065cc26c4ec4ae009854b84d00ce,
title = "TU‐A‐202‐01: Peak Skin Dose Reconstruction and TJC Sentinel Event",
abstract = "In 2005, the Joint Commission established a new reviewable Sentinel Event tied to radiation exposure. Proper identification and investigation of Sentinel Events are critical issues for maintaining Joint Commission accreditation of a hospital, mandating that the physicist correctly approach this problem. The newly defined sentinel event treats both radiotherapy and fluoroscopy, but we consider only the issues arising from the specific inclusion of prolonged fluoroscopy procedures that result in high (> 1500 rads) cumulative skin doses. The specific details of what constitutes the fluoroscopic Sentinel Event, mechanisms for detecting potential events, how to investigate an event, and what happens in the course of reviewing a Sentinel Event are addressed. The air kerma monitors required by the FDA on fluoroscopic equipment manufactured since 2006 are very useful tools for dose determination in these cases, but they do not provide a direct or complete answer. Case studies are reviewed that illustrate how to estimate doses both with and without cumulative air kerma readings. Learning Objectives: 1. Review the definitions of the new Joint Commission Sentinel Event for fluoroscopic radiation exposure. 2. Identify monitoring policies and procedures to detect potential fluoroscopic Sentinel Events. 3. Discuss practical aspects and pitfalls of using air kerma monitors and technique values to calculate maximum skin doses.",
author = "J. Anderson and G. Arbique and J. Guild",
year = "2010",
doi = "10.1118/1.3469181",
language = "English (US)",
volume = "37",
pages = "3373",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - TU‐A‐202‐01

T2 - Peak Skin Dose Reconstruction and TJC Sentinel Event

AU - Anderson, J.

AU - Arbique, G.

AU - Guild, J.

PY - 2010

Y1 - 2010

N2 - In 2005, the Joint Commission established a new reviewable Sentinel Event tied to radiation exposure. Proper identification and investigation of Sentinel Events are critical issues for maintaining Joint Commission accreditation of a hospital, mandating that the physicist correctly approach this problem. The newly defined sentinel event treats both radiotherapy and fluoroscopy, but we consider only the issues arising from the specific inclusion of prolonged fluoroscopy procedures that result in high (> 1500 rads) cumulative skin doses. The specific details of what constitutes the fluoroscopic Sentinel Event, mechanisms for detecting potential events, how to investigate an event, and what happens in the course of reviewing a Sentinel Event are addressed. The air kerma monitors required by the FDA on fluoroscopic equipment manufactured since 2006 are very useful tools for dose determination in these cases, but they do not provide a direct or complete answer. Case studies are reviewed that illustrate how to estimate doses both with and without cumulative air kerma readings. Learning Objectives: 1. Review the definitions of the new Joint Commission Sentinel Event for fluoroscopic radiation exposure. 2. Identify monitoring policies and procedures to detect potential fluoroscopic Sentinel Events. 3. Discuss practical aspects and pitfalls of using air kerma monitors and technique values to calculate maximum skin doses.

AB - In 2005, the Joint Commission established a new reviewable Sentinel Event tied to radiation exposure. Proper identification and investigation of Sentinel Events are critical issues for maintaining Joint Commission accreditation of a hospital, mandating that the physicist correctly approach this problem. The newly defined sentinel event treats both radiotherapy and fluoroscopy, but we consider only the issues arising from the specific inclusion of prolonged fluoroscopy procedures that result in high (> 1500 rads) cumulative skin doses. The specific details of what constitutes the fluoroscopic Sentinel Event, mechanisms for detecting potential events, how to investigate an event, and what happens in the course of reviewing a Sentinel Event are addressed. The air kerma monitors required by the FDA on fluoroscopic equipment manufactured since 2006 are very useful tools for dose determination in these cases, but they do not provide a direct or complete answer. Case studies are reviewed that illustrate how to estimate doses both with and without cumulative air kerma readings. Learning Objectives: 1. Review the definitions of the new Joint Commission Sentinel Event for fluoroscopic radiation exposure. 2. Identify monitoring policies and procedures to detect potential fluoroscopic Sentinel Events. 3. Discuss practical aspects and pitfalls of using air kerma monitors and technique values to calculate maximum skin doses.

UR - http://www.scopus.com/inward/record.url?scp=80053593733&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80053593733&partnerID=8YFLogxK

U2 - 10.1118/1.3469181

DO - 10.1118/1.3469181

M3 - Article

AN - SCOPUS:80053593733

VL - 37

SP - 3373

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -