TU‐G‐BRC‐03: A Novel Markerless Technique for Real‐Time Lung Tumor Tracking

W. Mao, T. Solberg

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: A critical component missing in the radiotherapy process for lung cancer is real‐time monitoring of lung tumors. The large planning margin that is typically required to account for rumor motion compromises sparing of critical structures and normal tissues. A novel markerless method has been developed to monitor lung tumor motion during treatment.Methods: The method automatically identifies lung tumors directly on continuous MV treatment beam images. Prior information from planning CT and contours is used to generate three sets of DRRs for lung tumors, other moving organs, and static organs, respectively. Composite DRRs are produced by combining three sets of DRRs, with weighting factors assigned to compensate for different attenuation coefficients between MV and kV x‐ray energies. Individual locations of three set of DRR are optimized by comparing with acquired MV treatment beam images using a normalized cross correlation algorithm. The method was evaluated by monitoring a target moving inside a chest cavity phantom. It was also applied retrospectively to online MV images from lung cancer patients. Results: In phantom studies, the target and target motion characteristics were successfully located within seven different treatment fields; the detected target locations have a maximum deviation of 0.8 mm from expected locations. Lung tumors in lung patients were successfully tracked. Although the planning 4D CT indicated that the lung tumor motion range was within 0 mm, real‐time tracking suggested that: a) the lung tumor motion pattern is not regular; and b) the average tumor locations, the respiratory frequencies, and the tumor motion amplitude (range) vary considerably during treatment. Conclusions: This tracking method, which requires no implanted markers and can be performed with no additional imaging dose, will enable clinicians to reduce margins and safely deliver higher doses by accounting for the effects of displacement and motion during treatment.

Original languageEnglish (US)
Pages (from-to)3781
Number of pages1
JournalMedical physics
Volume38
Issue number6
DOIs
StatePublished - Jun 2011

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'TU‐G‐BRC‐03: A Novel Markerless Technique for Real‐Time Lung Tumor Tracking'. Together they form a unique fingerprint.

Cite this