Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats

D. Guimarães, J. P. Santos, M. L. Carvalho, G. Vale, H. M. Santos, V. Geraldes, I. Rocha, J. L. Capelo

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

An ultrasonic assisted solid-liquid extraction method was developed to determine the level of lead in the brain and urine of rats. Lead was determined by electrothermal atomic absorption spectrometry with longitudinal-Zeeman background correction. Several analytical drawbacks were addressed and overcome, namely small brain sample mass and the formation of precipitate in the urine samples. Utrasonication provided by an ultrasonic probe succeeded in extracting lead from brain samples. Furthermore, it was demonstrated that the formation of a precipitate lowered the lead content in the liquid phase of the urine. Lead was back extracted from the precipitate to the liquid phase with the aid of ultrasonic energy and acidifying the urine with 10% v/v nitric acid. A microwave-assisted acid digestion protocol was used to check the completeness of the lead extraction. The within bath and between bath precision was 5% (n = 9) and 7% (n = 3) respectively. The limit of quantification was 1.05 μg g -1 for brain samples and 2.1 μg L -1 for urine samples. A total of 6 samples of urine and 12 samples of brain from control rats and another 6 samples of urine and 12 samples of brain from rats fed with tap water rich in lead acetate were used in this research. Lead levels in brain and urine from exposed rats ranged from1.9 ± 0.2 μg g -1 to 3.5 ± 0.2 μg g -1 and from 752 ± 56 μg L -1 to 60.9 ± 1.2 mg L -1 respectively. Statistically significant differences of levels of lead in brain and urine were found between exposed and non exposed rats.

Original languageEnglish (US)
Pages (from-to)442-446
Number of pages5
JournalTalanta
Volume86
Issue number1
DOIs
StatePublished - Oct 30 2011

Fingerprint

Ultrasonics
Rats
Brain
Urine
Tissue
Precipitates
Baths
Liquids
Rat control
Nitric Acid
Atomic absorption spectrometry
Lead
Microwaves
Digestion
Spectrum Analysis
Acids
Water
Research

Keywords

  • Brain
  • Electrothermal atomization
  • Lead
  • Pb
  • Rats
  • Ultrasonic
  • Urine

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Guimarães, D., Santos, J. P., Carvalho, M. L., Vale, G., Santos, H. M., Geraldes, V., ... Capelo, J. L. (2011). Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats. Talanta, 86(1), 442-446. https://doi.org/10.1016/j.talanta.2011.09.001

Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats. / Guimarães, D.; Santos, J. P.; Carvalho, M. L.; Vale, G.; Santos, H. M.; Geraldes, V.; Rocha, I.; Capelo, J. L.

In: Talanta, Vol. 86, No. 1, 30.10.2011, p. 442-446.

Research output: Contribution to journalArticle

Guimarães, D, Santos, JP, Carvalho, ML, Vale, G, Santos, HM, Geraldes, V, Rocha, I & Capelo, JL 2011, 'Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats', Talanta, vol. 86, no. 1, pp. 442-446. https://doi.org/10.1016/j.talanta.2011.09.001
Guimarães, D. ; Santos, J. P. ; Carvalho, M. L. ; Vale, G. ; Santos, H. M. ; Geraldes, V. ; Rocha, I. ; Capelo, J. L. / Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats. In: Talanta. 2011 ; Vol. 86, No. 1. pp. 442-446.
@article{e65ab1abfcbe421b96c47e1c1c693515,
title = "Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats",
abstract = "An ultrasonic assisted solid-liquid extraction method was developed to determine the level of lead in the brain and urine of rats. Lead was determined by electrothermal atomic absorption spectrometry with longitudinal-Zeeman background correction. Several analytical drawbacks were addressed and overcome, namely small brain sample mass and the formation of precipitate in the urine samples. Utrasonication provided by an ultrasonic probe succeeded in extracting lead from brain samples. Furthermore, it was demonstrated that the formation of a precipitate lowered the lead content in the liquid phase of the urine. Lead was back extracted from the precipitate to the liquid phase with the aid of ultrasonic energy and acidifying the urine with 10{\%} v/v nitric acid. A microwave-assisted acid digestion protocol was used to check the completeness of the lead extraction. The within bath and between bath precision was 5{\%} (n = 9) and 7{\%} (n = 3) respectively. The limit of quantification was 1.05 μg g -1 for brain samples and 2.1 μg L -1 for urine samples. A total of 6 samples of urine and 12 samples of brain from control rats and another 6 samples of urine and 12 samples of brain from rats fed with tap water rich in lead acetate were used in this research. Lead levels in brain and urine from exposed rats ranged from1.9 ± 0.2 μg g -1 to 3.5 ± 0.2 μg g -1 and from 752 ± 56 μg L -1 to 60.9 ± 1.2 mg L -1 respectively. Statistically significant differences of levels of lead in brain and urine were found between exposed and non exposed rats.",
keywords = "Brain, Electrothermal atomization, Lead, Pb, Rats, Ultrasonic, Urine",
author = "D. Guimar{\~a}es and Santos, {J. P.} and Carvalho, {M. L.} and G. Vale and Santos, {H. M.} and V. Geraldes and I. Rocha and Capelo, {J. L.}",
year = "2011",
month = "10",
day = "30",
doi = "10.1016/j.talanta.2011.09.001",
language = "English (US)",
volume = "86",
pages = "442--446",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats

AU - Guimarães, D.

AU - Santos, J. P.

AU - Carvalho, M. L.

AU - Vale, G.

AU - Santos, H. M.

AU - Geraldes, V.

AU - Rocha, I.

AU - Capelo, J. L.

PY - 2011/10/30

Y1 - 2011/10/30

N2 - An ultrasonic assisted solid-liquid extraction method was developed to determine the level of lead in the brain and urine of rats. Lead was determined by electrothermal atomic absorption spectrometry with longitudinal-Zeeman background correction. Several analytical drawbacks were addressed and overcome, namely small brain sample mass and the formation of precipitate in the urine samples. Utrasonication provided by an ultrasonic probe succeeded in extracting lead from brain samples. Furthermore, it was demonstrated that the formation of a precipitate lowered the lead content in the liquid phase of the urine. Lead was back extracted from the precipitate to the liquid phase with the aid of ultrasonic energy and acidifying the urine with 10% v/v nitric acid. A microwave-assisted acid digestion protocol was used to check the completeness of the lead extraction. The within bath and between bath precision was 5% (n = 9) and 7% (n = 3) respectively. The limit of quantification was 1.05 μg g -1 for brain samples and 2.1 μg L -1 for urine samples. A total of 6 samples of urine and 12 samples of brain from control rats and another 6 samples of urine and 12 samples of brain from rats fed with tap water rich in lead acetate were used in this research. Lead levels in brain and urine from exposed rats ranged from1.9 ± 0.2 μg g -1 to 3.5 ± 0.2 μg g -1 and from 752 ± 56 μg L -1 to 60.9 ± 1.2 mg L -1 respectively. Statistically significant differences of levels of lead in brain and urine were found between exposed and non exposed rats.

AB - An ultrasonic assisted solid-liquid extraction method was developed to determine the level of lead in the brain and urine of rats. Lead was determined by electrothermal atomic absorption spectrometry with longitudinal-Zeeman background correction. Several analytical drawbacks were addressed and overcome, namely small brain sample mass and the formation of precipitate in the urine samples. Utrasonication provided by an ultrasonic probe succeeded in extracting lead from brain samples. Furthermore, it was demonstrated that the formation of a precipitate lowered the lead content in the liquid phase of the urine. Lead was back extracted from the precipitate to the liquid phase with the aid of ultrasonic energy and acidifying the urine with 10% v/v nitric acid. A microwave-assisted acid digestion protocol was used to check the completeness of the lead extraction. The within bath and between bath precision was 5% (n = 9) and 7% (n = 3) respectively. The limit of quantification was 1.05 μg g -1 for brain samples and 2.1 μg L -1 for urine samples. A total of 6 samples of urine and 12 samples of brain from control rats and another 6 samples of urine and 12 samples of brain from rats fed with tap water rich in lead acetate were used in this research. Lead levels in brain and urine from exposed rats ranged from1.9 ± 0.2 μg g -1 to 3.5 ± 0.2 μg g -1 and from 752 ± 56 μg L -1 to 60.9 ± 1.2 mg L -1 respectively. Statistically significant differences of levels of lead in brain and urine were found between exposed and non exposed rats.

KW - Brain

KW - Electrothermal atomization

KW - Lead

KW - Pb

KW - Rats

KW - Ultrasonic

KW - Urine

UR - http://www.scopus.com/inward/record.url?scp=80755140095&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80755140095&partnerID=8YFLogxK

U2 - 10.1016/j.talanta.2011.09.001

DO - 10.1016/j.talanta.2011.09.001

M3 - Article

C2 - 22063564

AN - SCOPUS:80755140095

VL - 86

SP - 442

EP - 446

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 1

ER -