Universal ProbeLibrary based real-time PCR for rapid detection of bacterial pathogens from positive blood culture bottles

Lingxiang Zhu, Ding Xia Shen, Qiming Zhou, Chao Jun Liu, Zexia Li, Xiangdong Fang, Quan Zhen Li

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

A set of real-time PCR based assays using the locked nucleic acid probes from Roche Universal ProbeLibrary were developed for rapid detection of eight bacterial species from positive blood culture bottles. Four duplex real-time PCR reactions targeting to one Gram-positive bacterium and one Gram-negative bacterium were optimized for species identification according to Gram stain results. We also included mecA-specific primers and probes in the assays to indicate the presence of methicillin resistance in the bacterial species. The analytical sensitivity was in the range of 1-10 CFU per PCR reaction mixture. The specificity and cross reactivity of the assay was validated by 28 ATCC reference strains and 77 negative blood culture specimens. No cross-reactivity was observed in these samples thus demonstrating 100 % specificity. 72 previously characterized clinical isolates were tested by the real-time PCR assay and validated the accuracy and feasibility of the real-time PCR assay. Furthermore, 55 positive blood culture samples were tested using real-time PCR and 50 (90.9 %) of them were identified as the same species as judged by biochemical analysis. In total, real-time PCR showed 98.2 % consistent to that of traditional methods. Real-time PCR can be used as a supplement for early detection of the frequently-occurred pathogens from the positive blood cultures.

Original languageEnglish (US)
Pages (from-to)967-975
Number of pages9
JournalWorld Journal of Microbiology and Biotechnology
Volume30
Issue number3
DOIs
StatePublished - Mar 2014

Fingerprint

Real-Time Polymerase Chain Reaction
Nucleic Acid Probes
Methicillin Resistance
Gram-Positive Bacteria
Blood Culture
Gram-Negative Bacteria
Polymerase Chain Reaction

Keywords

  • Bacteria identification
  • Locked nucleic acid (LNA)
  • Real-time PCR
  • Universal ProbeLibrary

ASJC Scopus subject areas

  • Biotechnology
  • Physiology
  • Applied Microbiology and Biotechnology
  • Medicine(all)

Cite this

Universal ProbeLibrary based real-time PCR for rapid detection of bacterial pathogens from positive blood culture bottles. / Zhu, Lingxiang; Shen, Ding Xia; Zhou, Qiming; Liu, Chao Jun; Li, Zexia; Fang, Xiangdong; Li, Quan Zhen.

In: World Journal of Microbiology and Biotechnology, Vol. 30, No. 3, 03.2014, p. 967-975.

Research output: Contribution to journalArticle

Zhu, Lingxiang ; Shen, Ding Xia ; Zhou, Qiming ; Liu, Chao Jun ; Li, Zexia ; Fang, Xiangdong ; Li, Quan Zhen. / Universal ProbeLibrary based real-time PCR for rapid detection of bacterial pathogens from positive blood culture bottles. In: World Journal of Microbiology and Biotechnology. 2014 ; Vol. 30, No. 3. pp. 967-975.
@article{256755983a2442ef848c39f22d566d08,
title = "Universal ProbeLibrary based real-time PCR for rapid detection of bacterial pathogens from positive blood culture bottles",
abstract = "A set of real-time PCR based assays using the locked nucleic acid probes from Roche Universal ProbeLibrary were developed for rapid detection of eight bacterial species from positive blood culture bottles. Four duplex real-time PCR reactions targeting to one Gram-positive bacterium and one Gram-negative bacterium were optimized for species identification according to Gram stain results. We also included mecA-specific primers and probes in the assays to indicate the presence of methicillin resistance in the bacterial species. The analytical sensitivity was in the range of 1-10 CFU per PCR reaction mixture. The specificity and cross reactivity of the assay was validated by 28 ATCC reference strains and 77 negative blood culture specimens. No cross-reactivity was observed in these samples thus demonstrating 100 {\%} specificity. 72 previously characterized clinical isolates were tested by the real-time PCR assay and validated the accuracy and feasibility of the real-time PCR assay. Furthermore, 55 positive blood culture samples were tested using real-time PCR and 50 (90.9 {\%}) of them were identified as the same species as judged by biochemical analysis. In total, real-time PCR showed 98.2 {\%} consistent to that of traditional methods. Real-time PCR can be used as a supplement for early detection of the frequently-occurred pathogens from the positive blood cultures.",
keywords = "Bacteria identification, Locked nucleic acid (LNA), Real-time PCR, Universal ProbeLibrary",
author = "Lingxiang Zhu and Shen, {Ding Xia} and Qiming Zhou and Liu, {Chao Jun} and Zexia Li and Xiangdong Fang and Li, {Quan Zhen}",
year = "2014",
month = "3",
doi = "10.1007/s11274-013-1515-x",
language = "English (US)",
volume = "30",
pages = "967--975",
journal = "Mircen Journal of Applied Microbiology and Biotechnology",
issn = "0265-0762",
publisher = "Springer Netherlands",
number = "3",

}

TY - JOUR

T1 - Universal ProbeLibrary based real-time PCR for rapid detection of bacterial pathogens from positive blood culture bottles

AU - Zhu, Lingxiang

AU - Shen, Ding Xia

AU - Zhou, Qiming

AU - Liu, Chao Jun

AU - Li, Zexia

AU - Fang, Xiangdong

AU - Li, Quan Zhen

PY - 2014/3

Y1 - 2014/3

N2 - A set of real-time PCR based assays using the locked nucleic acid probes from Roche Universal ProbeLibrary were developed for rapid detection of eight bacterial species from positive blood culture bottles. Four duplex real-time PCR reactions targeting to one Gram-positive bacterium and one Gram-negative bacterium were optimized for species identification according to Gram stain results. We also included mecA-specific primers and probes in the assays to indicate the presence of methicillin resistance in the bacterial species. The analytical sensitivity was in the range of 1-10 CFU per PCR reaction mixture. The specificity and cross reactivity of the assay was validated by 28 ATCC reference strains and 77 negative blood culture specimens. No cross-reactivity was observed in these samples thus demonstrating 100 % specificity. 72 previously characterized clinical isolates were tested by the real-time PCR assay and validated the accuracy and feasibility of the real-time PCR assay. Furthermore, 55 positive blood culture samples were tested using real-time PCR and 50 (90.9 %) of them were identified as the same species as judged by biochemical analysis. In total, real-time PCR showed 98.2 % consistent to that of traditional methods. Real-time PCR can be used as a supplement for early detection of the frequently-occurred pathogens from the positive blood cultures.

AB - A set of real-time PCR based assays using the locked nucleic acid probes from Roche Universal ProbeLibrary were developed for rapid detection of eight bacterial species from positive blood culture bottles. Four duplex real-time PCR reactions targeting to one Gram-positive bacterium and one Gram-negative bacterium were optimized for species identification according to Gram stain results. We also included mecA-specific primers and probes in the assays to indicate the presence of methicillin resistance in the bacterial species. The analytical sensitivity was in the range of 1-10 CFU per PCR reaction mixture. The specificity and cross reactivity of the assay was validated by 28 ATCC reference strains and 77 negative blood culture specimens. No cross-reactivity was observed in these samples thus demonstrating 100 % specificity. 72 previously characterized clinical isolates were tested by the real-time PCR assay and validated the accuracy and feasibility of the real-time PCR assay. Furthermore, 55 positive blood culture samples were tested using real-time PCR and 50 (90.9 %) of them were identified as the same species as judged by biochemical analysis. In total, real-time PCR showed 98.2 % consistent to that of traditional methods. Real-time PCR can be used as a supplement for early detection of the frequently-occurred pathogens from the positive blood cultures.

KW - Bacteria identification

KW - Locked nucleic acid (LNA)

KW - Real-time PCR

KW - Universal ProbeLibrary

UR - http://www.scopus.com/inward/record.url?scp=84893579028&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893579028&partnerID=8YFLogxK

U2 - 10.1007/s11274-013-1515-x

DO - 10.1007/s11274-013-1515-x

M3 - Article

C2 - 24122126

AN - SCOPUS:84893579028

VL - 30

SP - 967

EP - 975

JO - Mircen Journal of Applied Microbiology and Biotechnology

JF - Mircen Journal of Applied Microbiology and Biotechnology

SN - 0265-0762

IS - 3

ER -