Variability of CT Attenuation Measurements in Virtual Unenhanced Images Generated Using Multimaterial Decomposition from Fast Kilovoltage-switching Dual-energy CT

Ravi K. Kaza, Evan A. Raff, Matthew S. Davenport, Shokoufeh Khalatbari

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

Rationale and Objectives To compare Hounsfield unit (HU) data obtained from true-unenhanced (TUE) and virtual-unenhanced (VUE) imaging obtained with a fast kv-switching dual-energy computed tomography (CT) scanner using multimaterial decomposition algorithm. Materials and Methods In this Institutional Review Board-approved, Health Insurance Portability and Accountability Act-compliant, retrospective cohort study, CT scans of 19 patients undergoing multiphasic renal protocol abdominal CT on a fast kv-switching dual-energy CT scanner were reviewed. CT numbers were measured on the matched TUE and VUE generated using a multimaterial decomposition algorithm with selective iodine suppression, and postcontrast images at predefined locations in seven organs. Six hundred sixty regions of interest were placed at 132 locations. Agreement was assessed with paired t test, Pearson's correlation, and Bland-Altman analysis. Results Mean TUE and VUE measurements were not significantly different in the corticomedullary (P = 0.25) or nephrographic (P = 0.10) phases. There was a strong correlation between TUE and VUE CT numbers (corticomedullary: r = 0.90, nephrographic: r = 0.90, each P < 0.001). Discrepancies ≥5 HU occurred 46 times (35%, 46 of 132) in the corticomedullary phase and 44 times (33%, 44 of 132) in the nephrographic phase. Discrepancies ≥10 HU occurred in 7% (9 of 132 in both corticomedullary and nephrographic phases). Interphase, intrasubject VUE CT numbers were strongly correlated (r = 0.93, P < 0.001), but discrepancies ≥5 HU (22% [29 of 132]) and ≥10 HU (2% [3 of 132]) occurred. There was no significant correlation between the true postcontrast CT number and the magnitude of VUE-TUE discrepancy (r = −0.04, P = 0.6). Conclusion CT numbers on VUE images generated from fast kv-switching dual-energy CT scans strongly correlate with TUE CT numbers on a population basis, but commonly vary 5–9 HU on a per-patient basis.

Original languageEnglish (US)
Pages (from-to)365-372
Number of pages8
JournalAcademic radiology
Volume24
Issue number3
DOIs
StatePublished - Mar 1 2017
Externally publishedYes

Keywords

  • Dual-energy CT
  • Virtual unenhanced imaging
  • multimaterial decomposition

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Variability of CT Attenuation Measurements in Virtual Unenhanced Images Generated Using Multimaterial Decomposition from Fast Kilovoltage-switching Dual-energy CT'. Together they form a unique fingerprint.

Cite this