WE‐C‐ValA‐04: Derivation of the Tumor Position From External Respiratory Surrogates with Periodical Updating of External/internal Correlation

E. Kanoulas, J. Aslam, G. Sharp, R. Berbeco, S. Nishioka, H. Shirato, S. Jiang

Research output: Contribution to journalArticle

Abstract

Purpose: To develop techniques that can derive the tumor position from external respiratory surrogates through periodically updated internal/external correlation. Method and Materials: A simple linear function is used to express the correlation between tumor and surrogate motion. The function parameters are established during patient setup session with both tumor and surrogate positions measured at 30Hz rate. During treatment, the surrogate position, constantly acquired at 30Hz, is used to derive the tumor position. Occasionally, a tumor image is acquired to enable the updating of the correlation function. Four update methods are investigated. (a) Line shift. (b) Fit model — through point. (c) Fit model — extra weight. (d) Function difference — fit point. Results: Tumor and external surrogate motion demonstrates a high degree of correlation however it dynamically changes over time. Occasionally updating the correlation function leads to more accurate predictions than using external surrogates alone. At the lowest tumor imaging rate tested in this work (0.1Hz) an accuracy improvement of 10% over the prediction by the mere use of external surrogate was observed for the best update method. Update methods (a) and (b) derive the tumor position with larger accuracy than (c) and (d) in case of high imaging rates. The opposite is observed in case of low imaging rates. Conclusion: Occasional calibration of the tumor/external surrogate correlation during treatment substantially increases the accuracy of the tumor localization compared to tumor position derivation by using the external surrogate alone. This work is partially supported by CenSSIS.

Original languageEnglish (US)
Pages (from-to)2232-2233
Number of pages2
JournalMedical Physics
Volume33
Issue number6
DOIs
StatePublished - 2006

Fingerprint

Neoplasms
Calibration
Weights and Measures
Therapeutics

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

WE‐C‐ValA‐04 : Derivation of the Tumor Position From External Respiratory Surrogates with Periodical Updating of External/internal Correlation. / Kanoulas, E.; Aslam, J.; Sharp, G.; Berbeco, R.; Nishioka, S.; Shirato, H.; Jiang, S.

In: Medical Physics, Vol. 33, No. 6, 2006, p. 2232-2233.

Research output: Contribution to journalArticle

Kanoulas, E. ; Aslam, J. ; Sharp, G. ; Berbeco, R. ; Nishioka, S. ; Shirato, H. ; Jiang, S. / WE‐C‐ValA‐04 : Derivation of the Tumor Position From External Respiratory Surrogates with Periodical Updating of External/internal Correlation. In: Medical Physics. 2006 ; Vol. 33, No. 6. pp. 2232-2233.
@article{5122f1ee5ef54e9db231ba2e7637d026,
title = "WE‐C‐ValA‐04: Derivation of the Tumor Position From External Respiratory Surrogates with Periodical Updating of External/internal Correlation",
abstract = "Purpose: To develop techniques that can derive the tumor position from external respiratory surrogates through periodically updated internal/external correlation. Method and Materials: A simple linear function is used to express the correlation between tumor and surrogate motion. The function parameters are established during patient setup session with both tumor and surrogate positions measured at 30Hz rate. During treatment, the surrogate position, constantly acquired at 30Hz, is used to derive the tumor position. Occasionally, a tumor image is acquired to enable the updating of the correlation function. Four update methods are investigated. (a) Line shift. (b) Fit model — through point. (c) Fit model — extra weight. (d) Function difference — fit point. Results: Tumor and external surrogate motion demonstrates a high degree of correlation however it dynamically changes over time. Occasionally updating the correlation function leads to more accurate predictions than using external surrogates alone. At the lowest tumor imaging rate tested in this work (0.1Hz) an accuracy improvement of 10{\%} over the prediction by the mere use of external surrogate was observed for the best update method. Update methods (a) and (b) derive the tumor position with larger accuracy than (c) and (d) in case of high imaging rates. The opposite is observed in case of low imaging rates. Conclusion: Occasional calibration of the tumor/external surrogate correlation during treatment substantially increases the accuracy of the tumor localization compared to tumor position derivation by using the external surrogate alone. This work is partially supported by CenSSIS.",
author = "E. Kanoulas and J. Aslam and G. Sharp and R. Berbeco and S. Nishioka and H. Shirato and S. Jiang",
year = "2006",
doi = "10.1118/1.2241694",
language = "English (US)",
volume = "33",
pages = "2232--2233",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - WE‐C‐ValA‐04

T2 - Derivation of the Tumor Position From External Respiratory Surrogates with Periodical Updating of External/internal Correlation

AU - Kanoulas, E.

AU - Aslam, J.

AU - Sharp, G.

AU - Berbeco, R.

AU - Nishioka, S.

AU - Shirato, H.

AU - Jiang, S.

PY - 2006

Y1 - 2006

N2 - Purpose: To develop techniques that can derive the tumor position from external respiratory surrogates through periodically updated internal/external correlation. Method and Materials: A simple linear function is used to express the correlation between tumor and surrogate motion. The function parameters are established during patient setup session with both tumor and surrogate positions measured at 30Hz rate. During treatment, the surrogate position, constantly acquired at 30Hz, is used to derive the tumor position. Occasionally, a tumor image is acquired to enable the updating of the correlation function. Four update methods are investigated. (a) Line shift. (b) Fit model — through point. (c) Fit model — extra weight. (d) Function difference — fit point. Results: Tumor and external surrogate motion demonstrates a high degree of correlation however it dynamically changes over time. Occasionally updating the correlation function leads to more accurate predictions than using external surrogates alone. At the lowest tumor imaging rate tested in this work (0.1Hz) an accuracy improvement of 10% over the prediction by the mere use of external surrogate was observed for the best update method. Update methods (a) and (b) derive the tumor position with larger accuracy than (c) and (d) in case of high imaging rates. The opposite is observed in case of low imaging rates. Conclusion: Occasional calibration of the tumor/external surrogate correlation during treatment substantially increases the accuracy of the tumor localization compared to tumor position derivation by using the external surrogate alone. This work is partially supported by CenSSIS.

AB - Purpose: To develop techniques that can derive the tumor position from external respiratory surrogates through periodically updated internal/external correlation. Method and Materials: A simple linear function is used to express the correlation between tumor and surrogate motion. The function parameters are established during patient setup session with both tumor and surrogate positions measured at 30Hz rate. During treatment, the surrogate position, constantly acquired at 30Hz, is used to derive the tumor position. Occasionally, a tumor image is acquired to enable the updating of the correlation function. Four update methods are investigated. (a) Line shift. (b) Fit model — through point. (c) Fit model — extra weight. (d) Function difference — fit point. Results: Tumor and external surrogate motion demonstrates a high degree of correlation however it dynamically changes over time. Occasionally updating the correlation function leads to more accurate predictions than using external surrogates alone. At the lowest tumor imaging rate tested in this work (0.1Hz) an accuracy improvement of 10% over the prediction by the mere use of external surrogate was observed for the best update method. Update methods (a) and (b) derive the tumor position with larger accuracy than (c) and (d) in case of high imaging rates. The opposite is observed in case of low imaging rates. Conclusion: Occasional calibration of the tumor/external surrogate correlation during treatment substantially increases the accuracy of the tumor localization compared to tumor position derivation by using the external surrogate alone. This work is partially supported by CenSSIS.

UR - http://www.scopus.com/inward/record.url?scp=85024773699&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024773699&partnerID=8YFLogxK

U2 - 10.1118/1.2241694

DO - 10.1118/1.2241694

M3 - Article

AN - SCOPUS:85024773699

VL - 33

SP - 2232

EP - 2233

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -