N2 - Purpose To evaluate the accuracy of a three-dimensional dual phase (3D DP) whole-heart technique for cardiac volumetric assessment in pediatric patients with cardiac abnormalities. Materials and Methods The institutional approved this study, and informed consent was obtained from patients or their guardians. This prospective study involved 31 pediatric patients (mean age, 7.9 years; range, 15 days to 15 years) for the assessment of cardiac abnormalities using cardiovascular MR. A standard protocol was performed for assessing cardiac anatomy and function. For evaluating the 3D DP technique, statistical comparison with a 2D cine multi-slice technique (2D steady-state free-precession [SSFP]) was performed using linear regression, intraclass correlation coefficient, and Bland Altman plots. Results Left (LV) and right (RV) ventricular cardiac volumes obtained with the 3D DP technique were in strong agreement with those obtained with the 2D SSFP technique for small and large ventricular volumes. The intraclass correlation coefficients (ICC) between both techniques were 0.992 for the LV end-diastolic volume (EDV), 0.983 for the LV end-systolic volume (ESV), 0.952 for the LV-systolic volume (SV), 0.992 for the RV-EDV, 0.992 for the RV-ESV, 0.928 for the RV-SV. Interobserver analysis indicated good reproducibility for both the 2D SSFP and the 3D DP techniques. Conclusion The 3D DP technique provides as accurate cardiac volumes as the 2D SSFP technique in the pediatric population, but with the added benefits of easier data acquisition and detailed anatomical information of the whole heart and great vessels in a single free-breathing scan. J. Magn. Reson. Imaging 2014;39:708-716. © 2013 Wiley Periodicals, Inc.
AB - Purpose To evaluate the accuracy of a three-dimensional dual phase (3D DP) whole-heart technique for cardiac volumetric assessment in pediatric patients with cardiac abnormalities. Materials and Methods The institutional approved this study, and informed consent was obtained from patients or their guardians. This prospective study involved 31 pediatric patients (mean age, 7.9 years; range, 15 days to 15 years) for the assessment of cardiac abnormalities using cardiovascular MR. A standard protocol was performed for assessing cardiac anatomy and function. For evaluating the 3D DP technique, statistical comparison with a 2D cine multi-slice technique (2D steady-state free-precession [SSFP]) was performed using linear regression, intraclass correlation coefficient, and Bland Altman plots. Results Left (LV) and right (RV) ventricular cardiac volumes obtained with the 3D DP technique were in strong agreement with those obtained with the 2D SSFP technique for small and large ventricular volumes. The intraclass correlation coefficients (ICC) between both techniques were 0.992 for the LV end-diastolic volume (EDV), 0.983 for the LV end-systolic volume (ESV), 0.952 for the LV-systolic volume (SV), 0.992 for the RV-EDV, 0.992 for the RV-ESV, 0.928 for the RV-SV. Interobserver analysis indicated good reproducibility for both the 2D SSFP and the 3D DP techniques. Conclusion The 3D DP technique provides as accurate cardiac volumes as the 2D SSFP technique in the pediatric population, but with the added benefits of easier data acquisition and detailed anatomical information of the whole heart and great vessels in a single free-breathing scan. J. Magn. Reson. Imaging 2014;39:708-716. © 2013 Wiley Periodicals, Inc.
KW - 3D dual phase
KW - cardiac MR
KW - cardiac volumetric assessment
KW - congenital heart disease
KW - pediatric
UR - http://www.scopus.com/inward/record.url?scp=84894073244&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84894073244&partnerID=8YFLogxK
U2 - 10.1002/jmri.24203
DO - 10.1002/jmri.24203
M3 - Article
C2 - 23723135
AN - SCOPUS:84894073244
SN - 1053-1807
VL - 39
SP - 708
EP - 716
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 3
ER -