Diffusion-weighted MR neurography of extremity nerves with unidirectional motion-probing gradients at 3 t: Feasibility study

Lianxin Zhao, Guangbin Wang, Linlin Yang, Lebin Wu, Xiangtao Lin, Avneesh Chhabra

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

OBJECTIVE. The objective of our study was to show the feasibility and performance of diffusion-weighted MR neurography (MRN) of extremity nerves with unidirectional motionprobing gradients at 3 T. SUBJECTS AND METHODS. Forty-seven healthy volunteers and 10 patients underwent diffusion-weighted MRN of extremity nerves with unidirectional motion-probing gradients (anterior-posterior direction only) on a 3-T unit. Images were displayed using a maximum- intensity-projection technique. Two radiologists blindly and independently evaluated the imaging quality of extremity nerves on diffusion-weighted MRN images using a 4-point grading scale, with 4 indicating excellent quality and 1 indicating poor quality, and evaluated the relation of the lesion to adjacent nerves in patients. RESULTS. In volunteers, the long trajectories of major extremity nerves, including the radial, median, ulnar, sciatic, tibial, and common peroneal nerves, could be visualized 3D on diffusionweighted MRN images. The mean imaging quality scores of all nerves for observers 1 and 2 were 3.68 ± 0.70 (SD) and 3.70 ± 0.66, respectively. Interobserver agreement was good (? = 0.774). In patients, there was no discrepancy in imaging quality scores between observers. Scores of all nerves were 2-4 except in two patients with neurofibromatosis and one patient who underwent imaging soon after surgery. The extent of the lesions and the relationship of the lesions to the adjacent nerves were clearly depicted on diffusion-weighted MRN images of all patients. CONCLUSION. This preliminary study shows that 3-T diffusion-weighted MRN with unidirectional motion-probing gradients is feasible for 3D visualization of major extremity nerves. Diffusion-weighted MRN may enable nerve depiction and allow assessment of the anatomic relationship between lesions with diffusion restriction and adjacent nerves.

Original languageEnglish (US)
Pages (from-to)1106-1114
Number of pages9
JournalAmerican Journal of Roentgenology
Volume200
Issue number5
DOIs
StatePublished - May 1 2013

Fingerprint

Feasibility Studies
Extremities
Radial Nerve
Peroneal Nerve
Neurofibromatoses
Volunteers
Healthy Volunteers

Keywords

  • 3-T MRI
  • Diffusion-weighted imaging
  • Extremity nerve
  • Neurography
  • Unidirectional motion-probing gradients

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Diffusion-weighted MR neurography of extremity nerves with unidirectional motion-probing gradients at 3 t : Feasibility study. / Zhao, Lianxin; Wang, Guangbin; Yang, Linlin; Wu, Lebin; Lin, Xiangtao; Chhabra, Avneesh.

In: American Journal of Roentgenology, Vol. 200, No. 5, 01.05.2013, p. 1106-1114.

Research output: Contribution to journalArticle

Zhao, Lianxin ; Wang, Guangbin ; Yang, Linlin ; Wu, Lebin ; Lin, Xiangtao ; Chhabra, Avneesh. / Diffusion-weighted MR neurography of extremity nerves with unidirectional motion-probing gradients at 3 t : Feasibility study. In: American Journal of Roentgenology. 2013 ; Vol. 200, No. 5. pp. 1106-1114.
@article{eb8991c08d9848d0a3dd0d2e1d0d10aa,
title = "Diffusion-weighted MR neurography of extremity nerves with unidirectional motion-probing gradients at 3 t: Feasibility study",
abstract = "OBJECTIVE. The objective of our study was to show the feasibility and performance of diffusion-weighted MR neurography (MRN) of extremity nerves with unidirectional motionprobing gradients at 3 T. SUBJECTS AND METHODS. Forty-seven healthy volunteers and 10 patients underwent diffusion-weighted MRN of extremity nerves with unidirectional motion-probing gradients (anterior-posterior direction only) on a 3-T unit. Images were displayed using a maximum- intensity-projection technique. Two radiologists blindly and independently evaluated the imaging quality of extremity nerves on diffusion-weighted MRN images using a 4-point grading scale, with 4 indicating excellent quality and 1 indicating poor quality, and evaluated the relation of the lesion to adjacent nerves in patients. RESULTS. In volunteers, the long trajectories of major extremity nerves, including the radial, median, ulnar, sciatic, tibial, and common peroneal nerves, could be visualized 3D on diffusionweighted MRN images. The mean imaging quality scores of all nerves for observers 1 and 2 were 3.68 ± 0.70 (SD) and 3.70 ± 0.66, respectively. Interobserver agreement was good (? = 0.774). In patients, there was no discrepancy in imaging quality scores between observers. Scores of all nerves were 2-4 except in two patients with neurofibromatosis and one patient who underwent imaging soon after surgery. The extent of the lesions and the relationship of the lesions to the adjacent nerves were clearly depicted on diffusion-weighted MRN images of all patients. CONCLUSION. This preliminary study shows that 3-T diffusion-weighted MRN with unidirectional motion-probing gradients is feasible for 3D visualization of major extremity nerves. Diffusion-weighted MRN may enable nerve depiction and allow assessment of the anatomic relationship between lesions with diffusion restriction and adjacent nerves.",
keywords = "3-T MRI, Diffusion-weighted imaging, Extremity nerve, Neurography, Unidirectional motion-probing gradients",
author = "Lianxin Zhao and Guangbin Wang and Linlin Yang and Lebin Wu and Xiangtao Lin and Avneesh Chhabra",
year = "2013",
month = "5",
day = "1",
doi = "10.2214/AJR.12.9213",
language = "English (US)",
volume = "200",
pages = "1106--1114",
journal = "American Journal of Roentgenology",
issn = "0361-803X",
publisher = "American Roentgen Ray Society",
number = "5",

}

TY - JOUR

T1 - Diffusion-weighted MR neurography of extremity nerves with unidirectional motion-probing gradients at 3 t

T2 - Feasibility study

AU - Zhao, Lianxin

AU - Wang, Guangbin

AU - Yang, Linlin

AU - Wu, Lebin

AU - Lin, Xiangtao

AU - Chhabra, Avneesh

PY - 2013/5/1

Y1 - 2013/5/1

N2 - OBJECTIVE. The objective of our study was to show the feasibility and performance of diffusion-weighted MR neurography (MRN) of extremity nerves with unidirectional motionprobing gradients at 3 T. SUBJECTS AND METHODS. Forty-seven healthy volunteers and 10 patients underwent diffusion-weighted MRN of extremity nerves with unidirectional motion-probing gradients (anterior-posterior direction only) on a 3-T unit. Images were displayed using a maximum- intensity-projection technique. Two radiologists blindly and independently evaluated the imaging quality of extremity nerves on diffusion-weighted MRN images using a 4-point grading scale, with 4 indicating excellent quality and 1 indicating poor quality, and evaluated the relation of the lesion to adjacent nerves in patients. RESULTS. In volunteers, the long trajectories of major extremity nerves, including the radial, median, ulnar, sciatic, tibial, and common peroneal nerves, could be visualized 3D on diffusionweighted MRN images. The mean imaging quality scores of all nerves for observers 1 and 2 were 3.68 ± 0.70 (SD) and 3.70 ± 0.66, respectively. Interobserver agreement was good (? = 0.774). In patients, there was no discrepancy in imaging quality scores between observers. Scores of all nerves were 2-4 except in two patients with neurofibromatosis and one patient who underwent imaging soon after surgery. The extent of the lesions and the relationship of the lesions to the adjacent nerves were clearly depicted on diffusion-weighted MRN images of all patients. CONCLUSION. This preliminary study shows that 3-T diffusion-weighted MRN with unidirectional motion-probing gradients is feasible for 3D visualization of major extremity nerves. Diffusion-weighted MRN may enable nerve depiction and allow assessment of the anatomic relationship between lesions with diffusion restriction and adjacent nerves.

AB - OBJECTIVE. The objective of our study was to show the feasibility and performance of diffusion-weighted MR neurography (MRN) of extremity nerves with unidirectional motionprobing gradients at 3 T. SUBJECTS AND METHODS. Forty-seven healthy volunteers and 10 patients underwent diffusion-weighted MRN of extremity nerves with unidirectional motion-probing gradients (anterior-posterior direction only) on a 3-T unit. Images were displayed using a maximum- intensity-projection technique. Two radiologists blindly and independently evaluated the imaging quality of extremity nerves on diffusion-weighted MRN images using a 4-point grading scale, with 4 indicating excellent quality and 1 indicating poor quality, and evaluated the relation of the lesion to adjacent nerves in patients. RESULTS. In volunteers, the long trajectories of major extremity nerves, including the radial, median, ulnar, sciatic, tibial, and common peroneal nerves, could be visualized 3D on diffusionweighted MRN images. The mean imaging quality scores of all nerves for observers 1 and 2 were 3.68 ± 0.70 (SD) and 3.70 ± 0.66, respectively. Interobserver agreement was good (? = 0.774). In patients, there was no discrepancy in imaging quality scores between observers. Scores of all nerves were 2-4 except in two patients with neurofibromatosis and one patient who underwent imaging soon after surgery. The extent of the lesions and the relationship of the lesions to the adjacent nerves were clearly depicted on diffusion-weighted MRN images of all patients. CONCLUSION. This preliminary study shows that 3-T diffusion-weighted MRN with unidirectional motion-probing gradients is feasible for 3D visualization of major extremity nerves. Diffusion-weighted MRN may enable nerve depiction and allow assessment of the anatomic relationship between lesions with diffusion restriction and adjacent nerves.

KW - 3-T MRI

KW - Diffusion-weighted imaging

KW - Extremity nerve

KW - Neurography

KW - Unidirectional motion-probing gradients

UR - http://www.scopus.com/inward/record.url?scp=84879315839&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84879315839&partnerID=8YFLogxK

U2 - 10.2214/AJR.12.9213

DO - 10.2214/AJR.12.9213

M3 - Article

C2 - 23617497

AN - SCOPUS:84879315839

VL - 200

SP - 1106

EP - 1114

JO - American Journal of Roentgenology

JF - American Journal of Roentgenology

SN - 0361-803X

IS - 5

ER -