Doppler echocardiographic study of porcine bioprosthetic heart valves in the aortic valve position in patients without evidence of cardiac dysfunction

Sharon C. Reimold, Ajit P. Yoganathan, H. W. Sung, Lawrence H. Cohn, Martin G St John Sutton, Richard T. Lee

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

To study the natural history of the hemodynamic performance of bioprostnetic heart valves, Doppler echocardiograms were recorded in a group of clinically stable patients at 2 and 5 years after replacement of native aortic valves with bioprostnetic valves. Eighteen patients completed a 2-year and 26 patients a 5-year follow-up examination. The effective orifice areas of identical models of bioprosthetic valves (Hancock II) were determined in vitro in a left-sided heart pulse duplicator system. In vivo Doppler-derived effective orifice areas were compared with the in vitro measurements for the same valve size. At both the 2- and 5-year followup examinations, the Doppler-derived effective orifice area was significantly less than the in vitro area (p < 0.0001 at each interval). Ten of 16 valves evaluated serially decreased >0.20 cm2 in the Doppler-derived effective orifice area between studies. The mean decrease in effective orifice area in valves evaluated serially was 0.25 ± 0.29 cm2 (p < 0.005). The peak transaortic gradient increased from 21 ± 6 to 27 ± 8 mm Hg (p < 0.01). The mean transaortic gradient increased from 12 ± 4 to 15 ±7 mm Hg (p < 0.05). It is concluded that serial Doppler echocardiographic studies demonstrate a deterioration in the hemodynamic performance of bioprostnetic valves over time in patients with no symptoms or signs of valvular dysfunction and that Doppler echocardiography may be useful for identifying subclinical bioprostnetic valvular dysfunction.

Original languageEnglish (US)
Pages (from-to)611-615
Number of pages5
JournalThe American Journal of Cardiology
Volume67
Issue number7
DOIs
StatePublished - Mar 15 1991

Fingerprint

Heart Valves
Aortic Valve
Swine
Hemodynamics
Doppler Echocardiography
Natural History
Signs and Symptoms
In Vitro Techniques

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Doppler echocardiographic study of porcine bioprosthetic heart valves in the aortic valve position in patients without evidence of cardiac dysfunction. / Reimold, Sharon C.; Yoganathan, Ajit P.; Sung, H. W.; Cohn, Lawrence H.; Sutton, Martin G St John; Lee, Richard T.

In: The American Journal of Cardiology, Vol. 67, No. 7, 15.03.1991, p. 611-615.

Research output: Contribution to journalArticle

Reimold, Sharon C. ; Yoganathan, Ajit P. ; Sung, H. W. ; Cohn, Lawrence H. ; Sutton, Martin G St John ; Lee, Richard T. / Doppler echocardiographic study of porcine bioprosthetic heart valves in the aortic valve position in patients without evidence of cardiac dysfunction. In: The American Journal of Cardiology. 1991 ; Vol. 67, No. 7. pp. 611-615.
@article{ab7970e5e28c4cb2a8995ae9173c9d9e,
title = "Doppler echocardiographic study of porcine bioprosthetic heart valves in the aortic valve position in patients without evidence of cardiac dysfunction",
abstract = "To study the natural history of the hemodynamic performance of bioprostnetic heart valves, Doppler echocardiograms were recorded in a group of clinically stable patients at 2 and 5 years after replacement of native aortic valves with bioprostnetic valves. Eighteen patients completed a 2-year and 26 patients a 5-year follow-up examination. The effective orifice areas of identical models of bioprosthetic valves (Hancock II) were determined in vitro in a left-sided heart pulse duplicator system. In vivo Doppler-derived effective orifice areas were compared with the in vitro measurements for the same valve size. At both the 2- and 5-year followup examinations, the Doppler-derived effective orifice area was significantly less than the in vitro area (p < 0.0001 at each interval). Ten of 16 valves evaluated serially decreased >0.20 cm2 in the Doppler-derived effective orifice area between studies. The mean decrease in effective orifice area in valves evaluated serially was 0.25 ± 0.29 cm2 (p < 0.005). The peak transaortic gradient increased from 21 ± 6 to 27 ± 8 mm Hg (p < 0.01). The mean transaortic gradient increased from 12 ± 4 to 15 ±7 mm Hg (p < 0.05). It is concluded that serial Doppler echocardiographic studies demonstrate a deterioration in the hemodynamic performance of bioprostnetic valves over time in patients with no symptoms or signs of valvular dysfunction and that Doppler echocardiography may be useful for identifying subclinical bioprostnetic valvular dysfunction.",
author = "Reimold, {Sharon C.} and Yoganathan, {Ajit P.} and Sung, {H. W.} and Cohn, {Lawrence H.} and Sutton, {Martin G St John} and Lee, {Richard T.}",
year = "1991",
month = "3",
day = "15",
doi = "10.1016/0002-9149(91)90900-6",
language = "English (US)",
volume = "67",
pages = "611--615",
journal = "American Journal of Cardiology",
issn = "0002-9149",
publisher = "Elsevier Inc.",
number = "7",

}

TY - JOUR

T1 - Doppler echocardiographic study of porcine bioprosthetic heart valves in the aortic valve position in patients without evidence of cardiac dysfunction

AU - Reimold, Sharon C.

AU - Yoganathan, Ajit P.

AU - Sung, H. W.

AU - Cohn, Lawrence H.

AU - Sutton, Martin G St John

AU - Lee, Richard T.

PY - 1991/3/15

Y1 - 1991/3/15

N2 - To study the natural history of the hemodynamic performance of bioprostnetic heart valves, Doppler echocardiograms were recorded in a group of clinically stable patients at 2 and 5 years after replacement of native aortic valves with bioprostnetic valves. Eighteen patients completed a 2-year and 26 patients a 5-year follow-up examination. The effective orifice areas of identical models of bioprosthetic valves (Hancock II) were determined in vitro in a left-sided heart pulse duplicator system. In vivo Doppler-derived effective orifice areas were compared with the in vitro measurements for the same valve size. At both the 2- and 5-year followup examinations, the Doppler-derived effective orifice area was significantly less than the in vitro area (p < 0.0001 at each interval). Ten of 16 valves evaluated serially decreased >0.20 cm2 in the Doppler-derived effective orifice area between studies. The mean decrease in effective orifice area in valves evaluated serially was 0.25 ± 0.29 cm2 (p < 0.005). The peak transaortic gradient increased from 21 ± 6 to 27 ± 8 mm Hg (p < 0.01). The mean transaortic gradient increased from 12 ± 4 to 15 ±7 mm Hg (p < 0.05). It is concluded that serial Doppler echocardiographic studies demonstrate a deterioration in the hemodynamic performance of bioprostnetic valves over time in patients with no symptoms or signs of valvular dysfunction and that Doppler echocardiography may be useful for identifying subclinical bioprostnetic valvular dysfunction.

AB - To study the natural history of the hemodynamic performance of bioprostnetic heart valves, Doppler echocardiograms were recorded in a group of clinically stable patients at 2 and 5 years after replacement of native aortic valves with bioprostnetic valves. Eighteen patients completed a 2-year and 26 patients a 5-year follow-up examination. The effective orifice areas of identical models of bioprosthetic valves (Hancock II) were determined in vitro in a left-sided heart pulse duplicator system. In vivo Doppler-derived effective orifice areas were compared with the in vitro measurements for the same valve size. At both the 2- and 5-year followup examinations, the Doppler-derived effective orifice area was significantly less than the in vitro area (p < 0.0001 at each interval). Ten of 16 valves evaluated serially decreased >0.20 cm2 in the Doppler-derived effective orifice area between studies. The mean decrease in effective orifice area in valves evaluated serially was 0.25 ± 0.29 cm2 (p < 0.005). The peak transaortic gradient increased from 21 ± 6 to 27 ± 8 mm Hg (p < 0.01). The mean transaortic gradient increased from 12 ± 4 to 15 ±7 mm Hg (p < 0.05). It is concluded that serial Doppler echocardiographic studies demonstrate a deterioration in the hemodynamic performance of bioprostnetic valves over time in patients with no symptoms or signs of valvular dysfunction and that Doppler echocardiography may be useful for identifying subclinical bioprostnetic valvular dysfunction.

UR - http://www.scopus.com/inward/record.url?scp=0026027744&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026027744&partnerID=8YFLogxK

U2 - 10.1016/0002-9149(91)90900-6

DO - 10.1016/0002-9149(91)90900-6

M3 - Article

C2 - 2000794

AN - SCOPUS:0026027744

VL - 67

SP - 611

EP - 615

JO - American Journal of Cardiology

JF - American Journal of Cardiology

SN - 0002-9149

IS - 7

ER -