Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code

John J. DeMarco, Geoff Hugo, Timothy D. Solberg

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed consists of a solid palladium and silver core, respectively. A thin layer (0.5 μm of 125I is adsorbed onto the solid core for each seed and encased within a titanium housing. The BT-103-3 seed consists of a central gold marker and four resin balls encased within a titanium housing. A thin layer of 103Pd is bonded onto each resin ball. The dosimetric properties, including the dose rate constant, radial dose function, and anisotropy were calculated in water according to the TG-43 protocol using the Monte Carlo N-Particle code. The dose rate constant was calculated to be 0.955±0.005 and 0.967±0.005 cGy h-1 U-1 for the BT-125-1 and BT-125-2 seeds, respectively. A dose rate constant of 0.659±0.005 cGy h1 U-1 was calculated for the BT-103-3 seed. Radial dose function, g(r), calculated to a distance of 10 cm, and an isotropy function, F(r, θ), calculated for radii from 0.5 to 7.0 cm, were found to be in close agreement with previously published data.

Original languageEnglish (US)
Pages (from-to)662-668
Number of pages7
JournalMedical Physics
Volume29
Issue number5
DOIs
StatePublished - 2002

Fingerprint

Brachytherapy
Seeds
Titanium
Anisotropy
Palladium
Silver
Gold
Water
Pharmaceutical Preparations
BT 103

Keywords

  • Brachytherapy
  • I-125
  • MCNP
  • Monte Carlo
  • Pd-103

ASJC Scopus subject areas

  • Biophysics

Cite this

Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code. / DeMarco, John J.; Hugo, Geoff; Solberg, Timothy D.

In: Medical Physics, Vol. 29, No. 5, 2002, p. 662-668.

Research output: Contribution to journalArticle

DeMarco, John J. ; Hugo, Geoff ; Solberg, Timothy D. / Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code. In: Medical Physics. 2002 ; Vol. 29, No. 5. pp. 662-668.
@article{57257fd2fb4f46a68bd7feb7e6b67000,
title = "Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code",
abstract = "Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed consists of a solid palladium and silver core, respectively. A thin layer (0.5 μm of 125I is adsorbed onto the solid core for each seed and encased within a titanium housing. The BT-103-3 seed consists of a central gold marker and four resin balls encased within a titanium housing. A thin layer of 103Pd is bonded onto each resin ball. The dosimetric properties, including the dose rate constant, radial dose function, and anisotropy were calculated in water according to the TG-43 protocol using the Monte Carlo N-Particle code. The dose rate constant was calculated to be 0.955±0.005 and 0.967±0.005 cGy h-1 U-1 for the BT-125-1 and BT-125-2 seeds, respectively. A dose rate constant of 0.659±0.005 cGy h1 U-1 was calculated for the BT-103-3 seed. Radial dose function, g(r), calculated to a distance of 10 cm, and an isotropy function, F(r, θ), calculated for radii from 0.5 to 7.0 cm, were found to be in close agreement with previously published data.",
keywords = "Brachytherapy, I-125, MCNP, Monte Carlo, Pd-103",
author = "DeMarco, {John J.} and Geoff Hugo and Solberg, {Timothy D.}",
year = "2002",
doi = "10.1118/1.1469627",
language = "English (US)",
volume = "29",
pages = "662--668",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "5",

}

TY - JOUR

T1 - Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code

AU - DeMarco, John J.

AU - Hugo, Geoff

AU - Solberg, Timothy D.

PY - 2002

Y1 - 2002

N2 - Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed consists of a solid palladium and silver core, respectively. A thin layer (0.5 μm of 125I is adsorbed onto the solid core for each seed and encased within a titanium housing. The BT-103-3 seed consists of a central gold marker and four resin balls encased within a titanium housing. A thin layer of 103Pd is bonded onto each resin ball. The dosimetric properties, including the dose rate constant, radial dose function, and anisotropy were calculated in water according to the TG-43 protocol using the Monte Carlo N-Particle code. The dose rate constant was calculated to be 0.955±0.005 and 0.967±0.005 cGy h-1 U-1 for the BT-125-1 and BT-125-2 seeds, respectively. A dose rate constant of 0.659±0.005 cGy h1 U-1 was calculated for the BT-103-3 seed. Radial dose function, g(r), calculated to a distance of 10 cm, and an isotropy function, F(r, θ), calculated for radii from 0.5 to 7.0 cm, were found to be in close agreement with previously published data.

AB - Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed consists of a solid palladium and silver core, respectively. A thin layer (0.5 μm of 125I is adsorbed onto the solid core for each seed and encased within a titanium housing. The BT-103-3 seed consists of a central gold marker and four resin balls encased within a titanium housing. A thin layer of 103Pd is bonded onto each resin ball. The dosimetric properties, including the dose rate constant, radial dose function, and anisotropy were calculated in water according to the TG-43 protocol using the Monte Carlo N-Particle code. The dose rate constant was calculated to be 0.955±0.005 and 0.967±0.005 cGy h-1 U-1 for the BT-125-1 and BT-125-2 seeds, respectively. A dose rate constant of 0.659±0.005 cGy h1 U-1 was calculated for the BT-103-3 seed. Radial dose function, g(r), calculated to a distance of 10 cm, and an isotropy function, F(r, θ), calculated for radii from 0.5 to 7.0 cm, were found to be in close agreement with previously published data.

KW - Brachytherapy

KW - I-125

KW - MCNP

KW - Monte Carlo

KW - Pd-103

UR - http://www.scopus.com/inward/record.url?scp=0035999390&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035999390&partnerID=8YFLogxK

U2 - 10.1118/1.1469627

DO - 10.1118/1.1469627

M3 - Article

VL - 29

SP - 662

EP - 668

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 5

ER -