Doubly tunable double ring surface coil

Vyacheslav Volotovskyy, Boguslaw Tomanek, Ian Corbin, Richard Buist, Ursula I. Tuor, James Peeling

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

To perform multinuclear magnetic resonance spectroscopy and imaging, a coil with a high signal-to-noise ratio and spatially uniform B1 field that covers the same volume of interest at several frequencies is preferred. The design of a surface coil that reduces contaminating signals from the surface-lying tissues and improves uniformity of the B1 field within the same preselected volume for both 31P and 1H is described. Testing of the coil demonstrated acquisition of proton images and 31P spectra from a selected voxel in rat liver at 7 T.

Original languageEnglish (US)
Pages (from-to)11-16
Number of pages6
JournalConcepts in Magnetic Resonance Part B: Magnetic Resonance Engineering
Volume17
Issue number1
DOIs
StatePublished - Apr 2003

Fingerprint

Signal-To-Noise Ratio
Protons
Magnetic Resonance Spectroscopy
coils
Magnetic Resonance Imaging
Magnetic resonance spectroscopy
Liver
rings
Rats
Signal to noise ratio
magnetic resonance spectroscopy
Tissue
Imaging techniques
liver
rats
acquisition
Testing
signal to noise ratios
protons

Keywords

  • P spectroscopy
  • Localized MRS
  • Proton imaging
  • Surface coil

ASJC Scopus subject areas

  • Chemistry(all)
  • Physical and Theoretical Chemistry
  • Spectroscopy

Cite this

Doubly tunable double ring surface coil. / Volotovskyy, Vyacheslav; Tomanek, Boguslaw; Corbin, Ian; Buist, Richard; Tuor, Ursula I.; Peeling, James.

In: Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, Vol. 17, No. 1, 04.2003, p. 11-16.

Research output: Contribution to journalArticle

Volotovskyy, Vyacheslav ; Tomanek, Boguslaw ; Corbin, Ian ; Buist, Richard ; Tuor, Ursula I. ; Peeling, James. / Doubly tunable double ring surface coil. In: Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 2003 ; Vol. 17, No. 1. pp. 11-16.
@article{f658596cdc8d4d2396009b12a7e76e01,
title = "Doubly tunable double ring surface coil",
abstract = "To perform multinuclear magnetic resonance spectroscopy and imaging, a coil with a high signal-to-noise ratio and spatially uniform B1 field that covers the same volume of interest at several frequencies is preferred. The design of a surface coil that reduces contaminating signals from the surface-lying tissues and improves uniformity of the B1 field within the same preselected volume for both 31P and 1H is described. Testing of the coil demonstrated acquisition of proton images and 31P spectra from a selected voxel in rat liver at 7 T.",
keywords = "P spectroscopy, Localized MRS, Proton imaging, Surface coil",
author = "Vyacheslav Volotovskyy and Boguslaw Tomanek and Ian Corbin and Richard Buist and Tuor, {Ursula I.} and James Peeling",
year = "2003",
month = "4",
doi = "10.1002/cmr.b.10062",
language = "English (US)",
volume = "17",
pages = "11--16",
journal = "Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering",
issn = "1043-7347",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Doubly tunable double ring surface coil

AU - Volotovskyy, Vyacheslav

AU - Tomanek, Boguslaw

AU - Corbin, Ian

AU - Buist, Richard

AU - Tuor, Ursula I.

AU - Peeling, James

PY - 2003/4

Y1 - 2003/4

N2 - To perform multinuclear magnetic resonance spectroscopy and imaging, a coil with a high signal-to-noise ratio and spatially uniform B1 field that covers the same volume of interest at several frequencies is preferred. The design of a surface coil that reduces contaminating signals from the surface-lying tissues and improves uniformity of the B1 field within the same preselected volume for both 31P and 1H is described. Testing of the coil demonstrated acquisition of proton images and 31P spectra from a selected voxel in rat liver at 7 T.

AB - To perform multinuclear magnetic resonance spectroscopy and imaging, a coil with a high signal-to-noise ratio and spatially uniform B1 field that covers the same volume of interest at several frequencies is preferred. The design of a surface coil that reduces contaminating signals from the surface-lying tissues and improves uniformity of the B1 field within the same preselected volume for both 31P and 1H is described. Testing of the coil demonstrated acquisition of proton images and 31P spectra from a selected voxel in rat liver at 7 T.

KW - P spectroscopy

KW - Localized MRS

KW - Proton imaging

KW - Surface coil

UR - http://www.scopus.com/inward/record.url?scp=18444406250&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=18444406250&partnerID=8YFLogxK

U2 - 10.1002/cmr.b.10062

DO - 10.1002/cmr.b.10062

M3 - Article

AN - SCOPUS:18444406250

VL - 17

SP - 11

EP - 16

JO - Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering

JF - Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering

SN - 1043-7347

IS - 1

ER -