Dual scintillator detection method to solve PSPMT edge resolving problem

Y. Shao, D. E. Castleberry, R. M. Manjeshwar

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

For the design of a high resolution PET detector based on PSPMTs (Position-Sensitive PMT), the insensitive area at the edge of the PSPMT normally prevents close packing of the scintillator crystals directly on the entire front face of the PSPMT. This edge-resolving problem is particularly severe for a high resolution PET system with multiple detector rings since it would cause gaps between detector rings and may lead to severe image artifacts. We have proposed a new method to solve this edge resolving problem by a dual scintillator detection method: it optically couples one scintillator at the insensitive edge of the PSPMT to another scintillator at the adjacent sensitive area; these two scintillators have different decay times. With this method, a gamma ray interaction that happens inside either scintillator can be detected, and the identification of which scintillator can be achieved by differentiating pulse shapes between the two scintillators. The feasibility of the method has been demonstrated with experiments measurements. Also, the artifacts from the missing data due to the gaps among detector rings has been investigated preliminarily with PET System Monte Carlo simulations.

Original languageEnglish (US)
Title of host publicationIEEE Nuclear Science Symposium and Medical Imaging Conference
EditorsS. Metzler
Pages1627-1631
Number of pages5
Volume3
StatePublished - Dec 1 2002
Event2002 IEEE Nuclear Science Symposium Conference Record - Norfolk, VA, United States
Duration: Nov 10 2002Nov 16 2002

Other

Other2002 IEEE Nuclear Science Symposium Conference Record
CountryUnited States
CityNorfolk, VA
Period11/10/0211/16/02

Fingerprint

Phosphors
Detectors
Gamma rays
Crystals

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Shao, Y., Castleberry, D. E., & Manjeshwar, R. M. (2002). Dual scintillator detection method to solve PSPMT edge resolving problem. In S. Metzler (Ed.), IEEE Nuclear Science Symposium and Medical Imaging Conference (Vol. 3, pp. 1627-1631)

Dual scintillator detection method to solve PSPMT edge resolving problem. / Shao, Y.; Castleberry, D. E.; Manjeshwar, R. M.

IEEE Nuclear Science Symposium and Medical Imaging Conference. ed. / S. Metzler. Vol. 3 2002. p. 1627-1631.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Shao, Y, Castleberry, DE & Manjeshwar, RM 2002, Dual scintillator detection method to solve PSPMT edge resolving problem. in S Metzler (ed.), IEEE Nuclear Science Symposium and Medical Imaging Conference. vol. 3, pp. 1627-1631, 2002 IEEE Nuclear Science Symposium Conference Record, Norfolk, VA, United States, 11/10/02.
Shao Y, Castleberry DE, Manjeshwar RM. Dual scintillator detection method to solve PSPMT edge resolving problem. In Metzler S, editor, IEEE Nuclear Science Symposium and Medical Imaging Conference. Vol. 3. 2002. p. 1627-1631
Shao, Y. ; Castleberry, D. E. ; Manjeshwar, R. M. / Dual scintillator detection method to solve PSPMT edge resolving problem. IEEE Nuclear Science Symposium and Medical Imaging Conference. editor / S. Metzler. Vol. 3 2002. pp. 1627-1631
@inproceedings{f7e42bd4142f463b8c62e4e103753660,
title = "Dual scintillator detection method to solve PSPMT edge resolving problem",
abstract = "For the design of a high resolution PET detector based on PSPMTs (Position-Sensitive PMT), the insensitive area at the edge of the PSPMT normally prevents close packing of the scintillator crystals directly on the entire front face of the PSPMT. This edge-resolving problem is particularly severe for a high resolution PET system with multiple detector rings since it would cause gaps between detector rings and may lead to severe image artifacts. We have proposed a new method to solve this edge resolving problem by a dual scintillator detection method: it optically couples one scintillator at the insensitive edge of the PSPMT to another scintillator at the adjacent sensitive area; these two scintillators have different decay times. With this method, a gamma ray interaction that happens inside either scintillator can be detected, and the identification of which scintillator can be achieved by differentiating pulse shapes between the two scintillators. The feasibility of the method has been demonstrated with experiments measurements. Also, the artifacts from the missing data due to the gaps among detector rings has been investigated preliminarily with PET System Monte Carlo simulations.",
author = "Y. Shao and Castleberry, {D. E.} and Manjeshwar, {R. M.}",
year = "2002",
month = "12",
day = "1",
language = "English (US)",
volume = "3",
pages = "1627--1631",
editor = "S. Metzler",
booktitle = "IEEE Nuclear Science Symposium and Medical Imaging Conference",

}

TY - GEN

T1 - Dual scintillator detection method to solve PSPMT edge resolving problem

AU - Shao, Y.

AU - Castleberry, D. E.

AU - Manjeshwar, R. M.

PY - 2002/12/1

Y1 - 2002/12/1

N2 - For the design of a high resolution PET detector based on PSPMTs (Position-Sensitive PMT), the insensitive area at the edge of the PSPMT normally prevents close packing of the scintillator crystals directly on the entire front face of the PSPMT. This edge-resolving problem is particularly severe for a high resolution PET system with multiple detector rings since it would cause gaps between detector rings and may lead to severe image artifacts. We have proposed a new method to solve this edge resolving problem by a dual scintillator detection method: it optically couples one scintillator at the insensitive edge of the PSPMT to another scintillator at the adjacent sensitive area; these two scintillators have different decay times. With this method, a gamma ray interaction that happens inside either scintillator can be detected, and the identification of which scintillator can be achieved by differentiating pulse shapes between the two scintillators. The feasibility of the method has been demonstrated with experiments measurements. Also, the artifacts from the missing data due to the gaps among detector rings has been investigated preliminarily with PET System Monte Carlo simulations.

AB - For the design of a high resolution PET detector based on PSPMTs (Position-Sensitive PMT), the insensitive area at the edge of the PSPMT normally prevents close packing of the scintillator crystals directly on the entire front face of the PSPMT. This edge-resolving problem is particularly severe for a high resolution PET system with multiple detector rings since it would cause gaps between detector rings and may lead to severe image artifacts. We have proposed a new method to solve this edge resolving problem by a dual scintillator detection method: it optically couples one scintillator at the insensitive edge of the PSPMT to another scintillator at the adjacent sensitive area; these two scintillators have different decay times. With this method, a gamma ray interaction that happens inside either scintillator can be detected, and the identification of which scintillator can be achieved by differentiating pulse shapes between the two scintillators. The feasibility of the method has been demonstrated with experiments measurements. Also, the artifacts from the missing data due to the gaps among detector rings has been investigated preliminarily with PET System Monte Carlo simulations.

UR - http://www.scopus.com/inward/record.url?scp=0142179011&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0142179011&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0142179011

VL - 3

SP - 1627

EP - 1631

BT - IEEE Nuclear Science Symposium and Medical Imaging Conference

A2 - Metzler, S.

ER -