High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure

T. Kawada, M. Li, S. Shimizu, A. Kamiya, K. Uemura, M. J. Turner, M. Mizuno, M. Sugimachi

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Aim: To examine whether dynamic characteristics of the peripheral vagal control of heart rate (HR) are altered in chronic heart failure (CHF). Methods: The right vagal nerve was electrically stimulated according to a binary white noise signal, and the transfer function from vagal nerve stimulation (VNS) to HR was estimated in the frequency range from 0.01 to 1 Hz in five control rats and five CHF rats under anaesthetized conditions. The rate of VNS was changed among 10, 20 and 40 Hz. Results: A multiple linear regression analysis indicated that the increase in the VNS rate augmented the ratio of the high-frequency (HF) gain to the steady-state gain in the control group but not in the CHF group. As a result, the dynamic gain of the transfer function in the frequencies near 1 Hz decreased more in the CHF group than in the control group. Conclusion: Changes in the dynamic characteristics of the peripheral vagal control of HR may contribute to the manifestation of decreased HF components of HR variability observed in CHF.

Original languageEnglish (US)
Pages (from-to)494-502
Number of pages9
JournalActa Physiologica
Volume207
Issue number3
DOIs
StatePublished - Mar 2013

Fingerprint

Vagus Nerve Stimulation
Heart Failure
Heart Rate
Control Groups
Linear Models
Regression Analysis

Keywords

  • Transfer function
  • Vagal nerve stimulation
  • White noise analysis

ASJC Scopus subject areas

  • Physiology

Cite this

Kawada, T., Li, M., Shimizu, S., Kamiya, A., Uemura, K., Turner, M. J., ... Sugimachi, M. (2013). High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure. Acta Physiologica, 207(3), 494-502. https://doi.org/10.1111/apha.12055

High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure. / Kawada, T.; Li, M.; Shimizu, S.; Kamiya, A.; Uemura, K.; Turner, M. J.; Mizuno, M.; Sugimachi, M.

In: Acta Physiologica, Vol. 207, No. 3, 03.2013, p. 494-502.

Research output: Contribution to journalArticle

Kawada, T, Li, M, Shimizu, S, Kamiya, A, Uemura, K, Turner, MJ, Mizuno, M & Sugimachi, M 2013, 'High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure', Acta Physiologica, vol. 207, no. 3, pp. 494-502. https://doi.org/10.1111/apha.12055
Kawada, T. ; Li, M. ; Shimizu, S. ; Kamiya, A. ; Uemura, K. ; Turner, M. J. ; Mizuno, M. ; Sugimachi, M. / High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure. In: Acta Physiologica. 2013 ; Vol. 207, No. 3. pp. 494-502.
@article{de7c94dc0e6f486db2e08ed9944f89b3,
title = "High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure",
abstract = "Aim: To examine whether dynamic characteristics of the peripheral vagal control of heart rate (HR) are altered in chronic heart failure (CHF). Methods: The right vagal nerve was electrically stimulated according to a binary white noise signal, and the transfer function from vagal nerve stimulation (VNS) to HR was estimated in the frequency range from 0.01 to 1 Hz in five control rats and five CHF rats under anaesthetized conditions. The rate of VNS was changed among 10, 20 and 40 Hz. Results: A multiple linear regression analysis indicated that the increase in the VNS rate augmented the ratio of the high-frequency (HF) gain to the steady-state gain in the control group but not in the CHF group. As a result, the dynamic gain of the transfer function in the frequencies near 1 Hz decreased more in the CHF group than in the control group. Conclusion: Changes in the dynamic characteristics of the peripheral vagal control of HR may contribute to the manifestation of decreased HF components of HR variability observed in CHF.",
keywords = "Transfer function, Vagal nerve stimulation, White noise analysis",
author = "T. Kawada and M. Li and S. Shimizu and A. Kamiya and K. Uemura and Turner, {M. J.} and M. Mizuno and M. Sugimachi",
year = "2013",
month = "3",
doi = "10.1111/apha.12055",
language = "English (US)",
volume = "207",
pages = "494--502",
journal = "Skandinavisches Archiv F{\"u}r Physiologie",
issn = "0370-839X",
publisher = "John Wiley and Sons Ltd",
number = "3",

}

TY - JOUR

T1 - High-frequency dominant depression of peripheral vagal control of heart rate in rats with chronic heart failure

AU - Kawada, T.

AU - Li, M.

AU - Shimizu, S.

AU - Kamiya, A.

AU - Uemura, K.

AU - Turner, M. J.

AU - Mizuno, M.

AU - Sugimachi, M.

PY - 2013/3

Y1 - 2013/3

N2 - Aim: To examine whether dynamic characteristics of the peripheral vagal control of heart rate (HR) are altered in chronic heart failure (CHF). Methods: The right vagal nerve was electrically stimulated according to a binary white noise signal, and the transfer function from vagal nerve stimulation (VNS) to HR was estimated in the frequency range from 0.01 to 1 Hz in five control rats and five CHF rats under anaesthetized conditions. The rate of VNS was changed among 10, 20 and 40 Hz. Results: A multiple linear regression analysis indicated that the increase in the VNS rate augmented the ratio of the high-frequency (HF) gain to the steady-state gain in the control group but not in the CHF group. As a result, the dynamic gain of the transfer function in the frequencies near 1 Hz decreased more in the CHF group than in the control group. Conclusion: Changes in the dynamic characteristics of the peripheral vagal control of HR may contribute to the manifestation of decreased HF components of HR variability observed in CHF.

AB - Aim: To examine whether dynamic characteristics of the peripheral vagal control of heart rate (HR) are altered in chronic heart failure (CHF). Methods: The right vagal nerve was electrically stimulated according to a binary white noise signal, and the transfer function from vagal nerve stimulation (VNS) to HR was estimated in the frequency range from 0.01 to 1 Hz in five control rats and five CHF rats under anaesthetized conditions. The rate of VNS was changed among 10, 20 and 40 Hz. Results: A multiple linear regression analysis indicated that the increase in the VNS rate augmented the ratio of the high-frequency (HF) gain to the steady-state gain in the control group but not in the CHF group. As a result, the dynamic gain of the transfer function in the frequencies near 1 Hz decreased more in the CHF group than in the control group. Conclusion: Changes in the dynamic characteristics of the peripheral vagal control of HR may contribute to the manifestation of decreased HF components of HR variability observed in CHF.

KW - Transfer function

KW - Vagal nerve stimulation

KW - White noise analysis

UR - http://www.scopus.com/inward/record.url?scp=84873416936&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84873416936&partnerID=8YFLogxK

U2 - 10.1111/apha.12055

DO - 10.1111/apha.12055

M3 - Article

C2 - 23279751

AN - SCOPUS:84873416936

VL - 207

SP - 494

EP - 502

JO - Skandinavisches Archiv Für Physiologie

JF - Skandinavisches Archiv Für Physiologie

SN - 0370-839X

IS - 3

ER -