In vivo imaging of paraCEST agents using frequency labeled exchange transfer MRI

Chien Yuan Lin, Nirbhay N. Yadav, James Ratnakar, A. Dean Sherry, Peter C M Van Zijl

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Purpose A main obstacle to in vivo applications of paramagnetic chemical exchange saturation transfer (paraCEST) is interference from endogenous tissue magnetization transfer contrast (MTC). The suitability of excitation-based frequency labeled exchange transfer (FLEX) to separate out such MTC effects in vivo was tested. Methods The FLEX sequence measures modulation of the water signal based on the chemical shift evolution of solute proton magnetization as a function of evolution time. Time-domain analysis of this water signal allows identification of different solute components and provides a mechanism to separate out the rapidly decaying MTC components with short effective transverse relaxation time (T2*) values. Results FLEX imaging of paraCEST agents was possible in vitro in phantoms and in vivo in mouse kidneys and bladder. The results demonstrated that FLEX is capable of separating out the MTC signal from tissues in vivo while providing a quantitative exchange rate for the rapidly exchanging paraCEST water protons by fitting the FLEX time-domain signal to FLEX theory. Conclusions The first in vivo FLEX images of a paraCEST agent were acquired, which allowed separation of the tissue MTC components. These results show that FLEX imaging has potential for imaging the distribution of functional paraCEST agents in biological tissues.

Original languageEnglish (US)
Pages (from-to)286-293
Number of pages8
JournalMagnetic Resonance in Medicine
Volume71
Issue number1
DOIs
StatePublished - Jan 2014

Fingerprint

Protons
Water
Chemical Evolution
Urinary Bladder
Kidney
In Vitro Techniques

Keywords

  • chemical exchange saturation transfer
  • exchange rate
  • magnetization transfer
  • paramagnetic contrast agent

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

In vivo imaging of paraCEST agents using frequency labeled exchange transfer MRI. / Lin, Chien Yuan; Yadav, Nirbhay N.; Ratnakar, James; Sherry, A. Dean; Van Zijl, Peter C M.

In: Magnetic Resonance in Medicine, Vol. 71, No. 1, 01.2014, p. 286-293.

Research output: Contribution to journalArticle

Lin, Chien Yuan ; Yadav, Nirbhay N. ; Ratnakar, James ; Sherry, A. Dean ; Van Zijl, Peter C M. / In vivo imaging of paraCEST agents using frequency labeled exchange transfer MRI. In: Magnetic Resonance in Medicine. 2014 ; Vol. 71, No. 1. pp. 286-293.
@article{f2104b4987a747d79b494a47219b4be4,
title = "In vivo imaging of paraCEST agents using frequency labeled exchange transfer MRI",
abstract = "Purpose A main obstacle to in vivo applications of paramagnetic chemical exchange saturation transfer (paraCEST) is interference from endogenous tissue magnetization transfer contrast (MTC). The suitability of excitation-based frequency labeled exchange transfer (FLEX) to separate out such MTC effects in vivo was tested. Methods The FLEX sequence measures modulation of the water signal based on the chemical shift evolution of solute proton magnetization as a function of evolution time. Time-domain analysis of this water signal allows identification of different solute components and provides a mechanism to separate out the rapidly decaying MTC components with short effective transverse relaxation time (T2*) values. Results FLEX imaging of paraCEST agents was possible in vitro in phantoms and in vivo in mouse kidneys and bladder. The results demonstrated that FLEX is capable of separating out the MTC signal from tissues in vivo while providing a quantitative exchange rate for the rapidly exchanging paraCEST water protons by fitting the FLEX time-domain signal to FLEX theory. Conclusions The first in vivo FLEX images of a paraCEST agent were acquired, which allowed separation of the tissue MTC components. These results show that FLEX imaging has potential for imaging the distribution of functional paraCEST agents in biological tissues.",
keywords = "chemical exchange saturation transfer, exchange rate, magnetization transfer, paramagnetic contrast agent",
author = "Lin, {Chien Yuan} and Yadav, {Nirbhay N.} and James Ratnakar and Sherry, {A. Dean} and {Van Zijl}, {Peter C M}",
year = "2014",
month = "1",
doi = "10.1002/mrm.24603",
language = "English (US)",
volume = "71",
pages = "286--293",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - In vivo imaging of paraCEST agents using frequency labeled exchange transfer MRI

AU - Lin, Chien Yuan

AU - Yadav, Nirbhay N.

AU - Ratnakar, James

AU - Sherry, A. Dean

AU - Van Zijl, Peter C M

PY - 2014/1

Y1 - 2014/1

N2 - Purpose A main obstacle to in vivo applications of paramagnetic chemical exchange saturation transfer (paraCEST) is interference from endogenous tissue magnetization transfer contrast (MTC). The suitability of excitation-based frequency labeled exchange transfer (FLEX) to separate out such MTC effects in vivo was tested. Methods The FLEX sequence measures modulation of the water signal based on the chemical shift evolution of solute proton magnetization as a function of evolution time. Time-domain analysis of this water signal allows identification of different solute components and provides a mechanism to separate out the rapidly decaying MTC components with short effective transverse relaxation time (T2*) values. Results FLEX imaging of paraCEST agents was possible in vitro in phantoms and in vivo in mouse kidneys and bladder. The results demonstrated that FLEX is capable of separating out the MTC signal from tissues in vivo while providing a quantitative exchange rate for the rapidly exchanging paraCEST water protons by fitting the FLEX time-domain signal to FLEX theory. Conclusions The first in vivo FLEX images of a paraCEST agent were acquired, which allowed separation of the tissue MTC components. These results show that FLEX imaging has potential for imaging the distribution of functional paraCEST agents in biological tissues.

AB - Purpose A main obstacle to in vivo applications of paramagnetic chemical exchange saturation transfer (paraCEST) is interference from endogenous tissue magnetization transfer contrast (MTC). The suitability of excitation-based frequency labeled exchange transfer (FLEX) to separate out such MTC effects in vivo was tested. Methods The FLEX sequence measures modulation of the water signal based on the chemical shift evolution of solute proton magnetization as a function of evolution time. Time-domain analysis of this water signal allows identification of different solute components and provides a mechanism to separate out the rapidly decaying MTC components with short effective transverse relaxation time (T2*) values. Results FLEX imaging of paraCEST agents was possible in vitro in phantoms and in vivo in mouse kidneys and bladder. The results demonstrated that FLEX is capable of separating out the MTC signal from tissues in vivo while providing a quantitative exchange rate for the rapidly exchanging paraCEST water protons by fitting the FLEX time-domain signal to FLEX theory. Conclusions The first in vivo FLEX images of a paraCEST agent were acquired, which allowed separation of the tissue MTC components. These results show that FLEX imaging has potential for imaging the distribution of functional paraCEST agents in biological tissues.

KW - chemical exchange saturation transfer

KW - exchange rate

KW - magnetization transfer

KW - paramagnetic contrast agent

UR - http://www.scopus.com/inward/record.url?scp=84890792258&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890792258&partnerID=8YFLogxK

U2 - 10.1002/mrm.24603

DO - 10.1002/mrm.24603

M3 - Article

VL - 71

SP - 286

EP - 293

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -