Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement: Report of a case

M. H. Huo, F. Betts, G. P. Bogumill, P. I. Kenmore, R. J. Hayek, T. J. Martinelli

Research output: Contribution to journalArticle

11 Citations (Scopus)
Original languageEnglish (US)
Pages (from-to)1277-1281
Number of pages5
JournalOrthopedics
Volume16
Issue number11
StatePublished - 1993

Fingerprint

Prosthesis Failure
Hip Prosthesis
Osteolysis
Hip Replacement Arthroplasties
Foreign Bodies

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Huo, M. H., Betts, F., Bogumill, G. P., Kenmore, P. I., Hayek, R. J., & Martinelli, T. J. (1993). Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement: Report of a case. Orthopedics, 16(11), 1277-1281.

Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement : Report of a case. / Huo, M. H.; Betts, F.; Bogumill, G. P.; Kenmore, P. I.; Hayek, R. J.; Martinelli, T. J.

In: Orthopedics, Vol. 16, No. 11, 1993, p. 1277-1281.

Research output: Contribution to journalArticle

Huo, MH, Betts, F, Bogumill, GP, Kenmore, PI, Hayek, RJ & Martinelli, TJ 1993, 'Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement: Report of a case', Orthopedics, vol. 16, no. 11, pp. 1277-1281.
Huo, M. H. ; Betts, F. ; Bogumill, G. P. ; Kenmore, P. I. ; Hayek, R. J. ; Martinelli, T. J. / Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement : Report of a case. In: Orthopedics. 1993 ; Vol. 16, No. 11. pp. 1277-1281.
@article{aca3390838524de8a432876c2efc8077,
title = "Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement: Report of a case",
author = "Huo, {M. H.} and F. Betts and Bogumill, {G. P.} and Kenmore, {P. I.} and Hayek, {R. J.} and Martinelli, {T. J.}",
year = "1993",
language = "English (US)",
volume = "16",
pages = "1277--1281",
journal = "Orthopedics",
issn = "0147-7447",
publisher = "Slack Incorporated",
number = "11",

}

TY - JOUR

T1 - Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement

T2 - Report of a case

AU - Huo, M. H.

AU - Betts, F.

AU - Bogumill, G. P.

AU - Kenmore, P. I.

AU - Hayek, R. J.

AU - Martinelli, T. J.

PY - 1993

Y1 - 1993

UR - http://www.scopus.com/inward/record.url?scp=0027368313&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027368313&partnerID=8YFLogxK

M3 - Article

C2 - 8290404

AN - SCOPUS:0027368313

VL - 16

SP - 1277

EP - 1281

JO - Orthopedics

JF - Orthopedics

SN - 0147-7447

IS - 11

ER -