Non-derivatization method for the determination of gabapentin in pharmaceutical formulations, rat serum and rat urine using high performance liquid chromatography coupled with charged aerosol detection

Shaodong Jia, Hee Seung Lee, Myung Joo Choi, Sang Hyun Sung, Sang B. Han, Jeong H. Park, Soon Sun Hong, Sung W. Kwon, Jeongmi Lee

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

A simple and sensitive isocratic reverse-phase high performance liquid chromatography method coupled with charged aerosol detection (HPLC-CAD) was developed and validated for the determination of gabapentin concentrations in a pharmaceutical formulation and in biological samples (rat serum and urine). Biological samples were simply treated with acetonitrile and directly injected into the HPLC without any further extraction or derivatization procedures. The separation was achieved on a GraceSmart RP-C18 packed column (250 ×4.6 mm, 5 μm) using a methanol-water (55:45, v/v) mobile phase at a flow rate of 1.1 mL/min at 30 °C. The total run time was less than 8 min. The standard calibration curves were linear (r 2 > 0.998) over the range of 2-300 μg/mL for the pharmaceutical formulation, 25-800 μg/mL for rat serum and 50-1600 μg/mL for rat urine. The limits of detection (signal/noise = 3) were 0.5 μg/mL, 10 μg/mL and 15 μg/mL for pharmaceutical formulation, serum and urine, respectively. The intra-day and inter-day precisions in the pharmaceutical formulation analysis ranged between 2.7-3.9% and 3.1-4.4%, respectively. In the rat serum analysis, the intra-day and inter-day precision ranges were 3.5-4.7% and 3.0-9.0%, respectively, while the rat urine analysis intra-day and inter-day precision ranges were 1.9-7.6% and 4.2-9.9%, respectively. The developed HPLC-CAD method successfully determined gabapentin concentrations in commercial gabapentin tablets, as well as in rat serum and urine samples after drug administration.

Original languageEnglish (US)
Pages (from-to)159-167
Number of pages9
JournalCurrent Analytical Chemistry
Volume8
Issue number1
StatePublished - Jan 2012

Fingerprint

High performance liquid chromatography
Aerosols
Rats
Pharmaceutical Preparations
Signal detection
Tablets
Methanol
gabapentin
Flow rate
Calibration
Water

Keywords

  • Charged aerosol detector
  • Commercial drug
  • Gabapentin
  • HPLC
  • Non-derivatization
  • Serum
  • Urine

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Non-derivatization method for the determination of gabapentin in pharmaceutical formulations, rat serum and rat urine using high performance liquid chromatography coupled with charged aerosol detection. / Jia, Shaodong; Lee, Hee Seung; Choi, Myung Joo; Sung, Sang Hyun; Han, Sang B.; Park, Jeong H.; Hong, Soon Sun; Kwon, Sung W.; Lee, Jeongmi.

In: Current Analytical Chemistry, Vol. 8, No. 1, 01.2012, p. 159-167.

Research output: Contribution to journalArticle

Jia, Shaodong ; Lee, Hee Seung ; Choi, Myung Joo ; Sung, Sang Hyun ; Han, Sang B. ; Park, Jeong H. ; Hong, Soon Sun ; Kwon, Sung W. ; Lee, Jeongmi. / Non-derivatization method for the determination of gabapentin in pharmaceutical formulations, rat serum and rat urine using high performance liquid chromatography coupled with charged aerosol detection. In: Current Analytical Chemistry. 2012 ; Vol. 8, No. 1. pp. 159-167.
@article{a13e8a5051ff401c8ca8041948d1bf64,
title = "Non-derivatization method for the determination of gabapentin in pharmaceutical formulations, rat serum and rat urine using high performance liquid chromatography coupled with charged aerosol detection",
abstract = "A simple and sensitive isocratic reverse-phase high performance liquid chromatography method coupled with charged aerosol detection (HPLC-CAD) was developed and validated for the determination of gabapentin concentrations in a pharmaceutical formulation and in biological samples (rat serum and urine). Biological samples were simply treated with acetonitrile and directly injected into the HPLC without any further extraction or derivatization procedures. The separation was achieved on a GraceSmart RP-C18 packed column (250 ×4.6 mm, 5 μm) using a methanol-water (55:45, v/v) mobile phase at a flow rate of 1.1 mL/min at 30 °C. The total run time was less than 8 min. The standard calibration curves were linear (r 2 > 0.998) over the range of 2-300 μg/mL for the pharmaceutical formulation, 25-800 μg/mL for rat serum and 50-1600 μg/mL for rat urine. The limits of detection (signal/noise = 3) were 0.5 μg/mL, 10 μg/mL and 15 μg/mL for pharmaceutical formulation, serum and urine, respectively. The intra-day and inter-day precisions in the pharmaceutical formulation analysis ranged between 2.7-3.9{\%} and 3.1-4.4{\%}, respectively. In the rat serum analysis, the intra-day and inter-day precision ranges were 3.5-4.7{\%} and 3.0-9.0{\%}, respectively, while the rat urine analysis intra-day and inter-day precision ranges were 1.9-7.6{\%} and 4.2-9.9{\%}, respectively. The developed HPLC-CAD method successfully determined gabapentin concentrations in commercial gabapentin tablets, as well as in rat serum and urine samples after drug administration.",
keywords = "Charged aerosol detector, Commercial drug, Gabapentin, HPLC, Non-derivatization, Serum, Urine",
author = "Shaodong Jia and Lee, {Hee Seung} and Choi, {Myung Joo} and Sung, {Sang Hyun} and Han, {Sang B.} and Park, {Jeong H.} and Hong, {Soon Sun} and Kwon, {Sung W.} and Jeongmi Lee",
year = "2012",
month = "1",
language = "English (US)",
volume = "8",
pages = "159--167",
journal = "Current Analytical Chemistry",
issn = "1573-4110",
publisher = "Bentham Science Publishers B.V.",
number = "1",

}

TY - JOUR

T1 - Non-derivatization method for the determination of gabapentin in pharmaceutical formulations, rat serum and rat urine using high performance liquid chromatography coupled with charged aerosol detection

AU - Jia, Shaodong

AU - Lee, Hee Seung

AU - Choi, Myung Joo

AU - Sung, Sang Hyun

AU - Han, Sang B.

AU - Park, Jeong H.

AU - Hong, Soon Sun

AU - Kwon, Sung W.

AU - Lee, Jeongmi

PY - 2012/1

Y1 - 2012/1

N2 - A simple and sensitive isocratic reverse-phase high performance liquid chromatography method coupled with charged aerosol detection (HPLC-CAD) was developed and validated for the determination of gabapentin concentrations in a pharmaceutical formulation and in biological samples (rat serum and urine). Biological samples were simply treated with acetonitrile and directly injected into the HPLC without any further extraction or derivatization procedures. The separation was achieved on a GraceSmart RP-C18 packed column (250 ×4.6 mm, 5 μm) using a methanol-water (55:45, v/v) mobile phase at a flow rate of 1.1 mL/min at 30 °C. The total run time was less than 8 min. The standard calibration curves were linear (r 2 > 0.998) over the range of 2-300 μg/mL for the pharmaceutical formulation, 25-800 μg/mL for rat serum and 50-1600 μg/mL for rat urine. The limits of detection (signal/noise = 3) were 0.5 μg/mL, 10 μg/mL and 15 μg/mL for pharmaceutical formulation, serum and urine, respectively. The intra-day and inter-day precisions in the pharmaceutical formulation analysis ranged between 2.7-3.9% and 3.1-4.4%, respectively. In the rat serum analysis, the intra-day and inter-day precision ranges were 3.5-4.7% and 3.0-9.0%, respectively, while the rat urine analysis intra-day and inter-day precision ranges were 1.9-7.6% and 4.2-9.9%, respectively. The developed HPLC-CAD method successfully determined gabapentin concentrations in commercial gabapentin tablets, as well as in rat serum and urine samples after drug administration.

AB - A simple and sensitive isocratic reverse-phase high performance liquid chromatography method coupled with charged aerosol detection (HPLC-CAD) was developed and validated for the determination of gabapentin concentrations in a pharmaceutical formulation and in biological samples (rat serum and urine). Biological samples were simply treated with acetonitrile and directly injected into the HPLC without any further extraction or derivatization procedures. The separation was achieved on a GraceSmart RP-C18 packed column (250 ×4.6 mm, 5 μm) using a methanol-water (55:45, v/v) mobile phase at a flow rate of 1.1 mL/min at 30 °C. The total run time was less than 8 min. The standard calibration curves were linear (r 2 > 0.998) over the range of 2-300 μg/mL for the pharmaceutical formulation, 25-800 μg/mL for rat serum and 50-1600 μg/mL for rat urine. The limits of detection (signal/noise = 3) were 0.5 μg/mL, 10 μg/mL and 15 μg/mL for pharmaceutical formulation, serum and urine, respectively. The intra-day and inter-day precisions in the pharmaceutical formulation analysis ranged between 2.7-3.9% and 3.1-4.4%, respectively. In the rat serum analysis, the intra-day and inter-day precision ranges were 3.5-4.7% and 3.0-9.0%, respectively, while the rat urine analysis intra-day and inter-day precision ranges were 1.9-7.6% and 4.2-9.9%, respectively. The developed HPLC-CAD method successfully determined gabapentin concentrations in commercial gabapentin tablets, as well as in rat serum and urine samples after drug administration.

KW - Charged aerosol detector

KW - Commercial drug

KW - Gabapentin

KW - HPLC

KW - Non-derivatization

KW - Serum

KW - Urine

UR - http://www.scopus.com/inward/record.url?scp=84855263165&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84855263165&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84855263165

VL - 8

SP - 159

EP - 167

JO - Current Analytical Chemistry

JF - Current Analytical Chemistry

SN - 1573-4110

IS - 1

ER -