Abstract

Peripheral nerve damage is routinely repaired by autogenic nerve grafting, often leading to less than optimal functional recovery at the expense of healthy donor nerves. Alternative repair strategies use tubular scaffolds to guide the regeneration of damaged nerves, but despite the progress made on improved structural materials for the nerve tubes, functional recovery remains incomplete. We developed a biosynthetic nerve implant (BNI) consisting of a hydrogel-based transparent multichannel scaffold with luminar collagen matrix as a 3-D substrate for nerve repair. Using a rat sciatic nerve injury model we showed axonal regeneration through the BNI to be histologically comparable to the autologous nerve repair. At 10 weeks post-injury, nerve defects repaired with collagen-filled, single lumen tubes formed single nerve cables, while animals that received the multi-luminal BNIs showed multiple nerve cables and the formation of a perineurial-like layer within the available microchannels. Total numbers of myelinated and unmyelinated axons in the BNI were increased 3-fold and 30%, respectively, compared to collagen tubes. The recovery of reflexive movement confirmed the functional regeneration of both motor and sensory neurons. This study supports the use of multi-luminal BNIs as a viable alternative to autografts in the repair of nerve gap injuries.

Original languageEnglish (US)
Pages (from-to)1815-1828
Number of pages14
JournalAnnals of Biomedical Engineering
Volume39
Issue number6
DOIs
StatePublished - Jun 2011

Fingerprint

Repair
Collagen
Recovery
Cables
Scaffolds (biology)
Microchannels
Hydrogels
Scaffolds
Neurons
Rats
Animals
Defects
Substrates

Keywords

  • Biosynthetic nerve implant
  • Collagen
  • Multi-luminal nerve repair
  • Peripheral nerve regeneration
  • Sensory fiber regeneration

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Peripheral nerve repair through multi-luminal biosynthetic implants. / Tansey, K. E.; Seifert, J. L.; Botterman, B.; Delgado, M. R.; Romero, M. I.

In: Annals of Biomedical Engineering, Vol. 39, No. 6, 06.2011, p. 1815-1828.

Research output: Contribution to journalArticle

Tansey, K. E. ; Seifert, J. L. ; Botterman, B. ; Delgado, M. R. ; Romero, M. I. / Peripheral nerve repair through multi-luminal biosynthetic implants. In: Annals of Biomedical Engineering. 2011 ; Vol. 39, No. 6. pp. 1815-1828.
@article{b6bfcb7237e34641bef9a47955940ebb,
title = "Peripheral nerve repair through multi-luminal biosynthetic implants",
abstract = "Peripheral nerve damage is routinely repaired by autogenic nerve grafting, often leading to less than optimal functional recovery at the expense of healthy donor nerves. Alternative repair strategies use tubular scaffolds to guide the regeneration of damaged nerves, but despite the progress made on improved structural materials for the nerve tubes, functional recovery remains incomplete. We developed a biosynthetic nerve implant (BNI) consisting of a hydrogel-based transparent multichannel scaffold with luminar collagen matrix as a 3-D substrate for nerve repair. Using a rat sciatic nerve injury model we showed axonal regeneration through the BNI to be histologically comparable to the autologous nerve repair. At 10 weeks post-injury, nerve defects repaired with collagen-filled, single lumen tubes formed single nerve cables, while animals that received the multi-luminal BNIs showed multiple nerve cables and the formation of a perineurial-like layer within the available microchannels. Total numbers of myelinated and unmyelinated axons in the BNI were increased 3-fold and 30{\%}, respectively, compared to collagen tubes. The recovery of reflexive movement confirmed the functional regeneration of both motor and sensory neurons. This study supports the use of multi-luminal BNIs as a viable alternative to autografts in the repair of nerve gap injuries.",
keywords = "Biosynthetic nerve implant, Collagen, Multi-luminal nerve repair, Peripheral nerve regeneration, Sensory fiber regeneration",
author = "Tansey, {K. E.} and Seifert, {J. L.} and B. Botterman and Delgado, {M. R.} and Romero, {M. I.}",
year = "2011",
month = "6",
doi = "10.1007/s10439-011-0277-6",
language = "English (US)",
volume = "39",
pages = "1815--1828",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "6",

}

TY - JOUR

T1 - Peripheral nerve repair through multi-luminal biosynthetic implants

AU - Tansey, K. E.

AU - Seifert, J. L.

AU - Botterman, B.

AU - Delgado, M. R.

AU - Romero, M. I.

PY - 2011/6

Y1 - 2011/6

N2 - Peripheral nerve damage is routinely repaired by autogenic nerve grafting, often leading to less than optimal functional recovery at the expense of healthy donor nerves. Alternative repair strategies use tubular scaffolds to guide the regeneration of damaged nerves, but despite the progress made on improved structural materials for the nerve tubes, functional recovery remains incomplete. We developed a biosynthetic nerve implant (BNI) consisting of a hydrogel-based transparent multichannel scaffold with luminar collagen matrix as a 3-D substrate for nerve repair. Using a rat sciatic nerve injury model we showed axonal regeneration through the BNI to be histologically comparable to the autologous nerve repair. At 10 weeks post-injury, nerve defects repaired with collagen-filled, single lumen tubes formed single nerve cables, while animals that received the multi-luminal BNIs showed multiple nerve cables and the formation of a perineurial-like layer within the available microchannels. Total numbers of myelinated and unmyelinated axons in the BNI were increased 3-fold and 30%, respectively, compared to collagen tubes. The recovery of reflexive movement confirmed the functional regeneration of both motor and sensory neurons. This study supports the use of multi-luminal BNIs as a viable alternative to autografts in the repair of nerve gap injuries.

AB - Peripheral nerve damage is routinely repaired by autogenic nerve grafting, often leading to less than optimal functional recovery at the expense of healthy donor nerves. Alternative repair strategies use tubular scaffolds to guide the regeneration of damaged nerves, but despite the progress made on improved structural materials for the nerve tubes, functional recovery remains incomplete. We developed a biosynthetic nerve implant (BNI) consisting of a hydrogel-based transparent multichannel scaffold with luminar collagen matrix as a 3-D substrate for nerve repair. Using a rat sciatic nerve injury model we showed axonal regeneration through the BNI to be histologically comparable to the autologous nerve repair. At 10 weeks post-injury, nerve defects repaired with collagen-filled, single lumen tubes formed single nerve cables, while animals that received the multi-luminal BNIs showed multiple nerve cables and the formation of a perineurial-like layer within the available microchannels. Total numbers of myelinated and unmyelinated axons in the BNI were increased 3-fold and 30%, respectively, compared to collagen tubes. The recovery of reflexive movement confirmed the functional regeneration of both motor and sensory neurons. This study supports the use of multi-luminal BNIs as a viable alternative to autografts in the repair of nerve gap injuries.

KW - Biosynthetic nerve implant

KW - Collagen

KW - Multi-luminal nerve repair

KW - Peripheral nerve regeneration

KW - Sensory fiber regeneration

UR - http://www.scopus.com/inward/record.url?scp=79958819182&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79958819182&partnerID=8YFLogxK

U2 - 10.1007/s10439-011-0277-6

DO - 10.1007/s10439-011-0277-6

M3 - Article

VL - 39

SP - 1815

EP - 1828

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 6

ER -