Practical no-gold-standard evaluation framework for quantitative imaging methods: Application to lesion segmentation in positron emission tomography

Abhinav K. Jha, Esther Mena, Brian Caffo, Saeed Ashrafinia, Arman Rahmim, Eric Frey, Rathan M. Subramaniam

Research output: Contribution to journalArticlepeer-review

17 Scopus citations

Abstract

Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis.

Original languageEnglish (US)
Article number011011
JournalJournal of Medical Imaging
Volume4
Issue number1
DOIs
StatePublished - Jan 1 2017

Keywords

  • metabolic tumor volume
  • no-gold-standard evaluation
  • positron emission tomography segmentation
  • quantitative imaging biomarkers

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Practical no-gold-standard evaluation framework for quantitative imaging methods: Application to lesion segmentation in positron emission tomography'. Together they form a unique fingerprint.

Cite this