Quantification de l'obstruction chez l'homme: Comparaison des ḿthodes usuelles avec la ḿthode VBN®

Translated title of the contribution: Quantification of bladder-outlet obstruction in males: Standard method vs VBN® method

F. A. Valentini, D. J. Griffiths, P. E. Zimmern, G. R. Besson, P. P. Nelson

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Goal. - To compare the merits of two methods, standard (Abrams-Griffiths number, Scḧ's classification, etc.) and VBN®, to study bladder-outlet obstruction in men with benign prostatic hyperplasia (BPH). Material and methods. - The parameters deduced from both methods and from repeated pressure-flow studies were computed for a population of patients with BPH. Correlation coefficients between standard and VBN parameters were systematically evaluated. Test-retest reliability and inter-rater reliability of the VBN parameters were investigated. Results. - The VBN obstruction parameter was linearly corelated to the A-G number (R =0.992) and thus is related to the provisional ICS obstruction nomogram. A simple modification to the standard index projected isometric pressure (PIP) yields an mPIP parameter strongly correlated with the VBN detrusor contraction-strength parameter (R =0.962). VBN analysis reveals minor phenomena such as premature fading of the detrusor contraction to be responsible for much of the void-to-void variability of pressure-flow studies. Consequently, the primary VBN obstruction and contraction-strength parameters exhibit better test-retest and inter-rater reliability than the standard parameters and are less sensitive to changes in testing circumstances (bladder volume, urethral catheter size and psychological factors). Conclusion. - With the standard approach to test bladder obstruction, two values: A-G and mPIP, derived from pressure-flow studies, best qualify the patient's voiding status. These parameters are simple to calculate but are sensitive to testing variations and minor phenomena. The VBN approach is more complicated, but its parameters for obstruction and detrusor contraction strength are less dependent on testing variations.

Original languageFrench
Pages (from-to)11-19
Number of pages9
JournalAnnales de Readaptation et de Medecine Physique
Volume48
Issue number1
DOIs
StatePublished - Feb 2005

Fingerprint

Urinary Bladder Neck Obstruction
Pressure
Prostatic Hyperplasia
Urinary Bladder
Urinary Catheters
Nomograms
Reproducibility of Results
Psychology
Population

Keywords

  • Benign prostatic hyperplasia
  • Contractilit́ du d́trusor
  • Detrusor contractility
  • Hypertrophie b́nigne de prostate
  • Obstruction uŕtrale
  • Urethral obstruction
  • Urodynamics
  • Urodynamique

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Quantification de l'obstruction chez l'homme : Comparaison des ḿthodes usuelles avec la ḿthode VBN®. / Valentini, F. A.; Griffiths, D. J.; Zimmern, P. E.; Besson, G. R.; Nelson, P. P.

In: Annales de Readaptation et de Medecine Physique, Vol. 48, No. 1, 02.2005, p. 11-19.

Research output: Contribution to journalArticle

@article{9acb9a37a2a54aad9be30a2b13f85c1c,
title = "Quantification de l'obstruction chez l'homme: Comparaison des ḿthodes usuelles avec la ḿthode VBN{\circledR}",
abstract = "Goal. - To compare the merits of two methods, standard (Abrams-Griffiths number, Scḧ's classification, etc.) and VBN{\circledR}, to study bladder-outlet obstruction in men with benign prostatic hyperplasia (BPH). Material and methods. - The parameters deduced from both methods and from repeated pressure-flow studies were computed for a population of patients with BPH. Correlation coefficients between standard and VBN parameters were systematically evaluated. Test-retest reliability and inter-rater reliability of the VBN parameters were investigated. Results. - The VBN obstruction parameter was linearly corelated to the A-G number (R =0.992) and thus is related to the provisional ICS obstruction nomogram. A simple modification to the standard index projected isometric pressure (PIP) yields an mPIP parameter strongly correlated with the VBN detrusor contraction-strength parameter (R =0.962). VBN analysis reveals minor phenomena such as premature fading of the detrusor contraction to be responsible for much of the void-to-void variability of pressure-flow studies. Consequently, the primary VBN obstruction and contraction-strength parameters exhibit better test-retest and inter-rater reliability than the standard parameters and are less sensitive to changes in testing circumstances (bladder volume, urethral catheter size and psychological factors). Conclusion. - With the standard approach to test bladder obstruction, two values: A-G and mPIP, derived from pressure-flow studies, best qualify the patient's voiding status. These parameters are simple to calculate but are sensitive to testing variations and minor phenomena. The VBN approach is more complicated, but its parameters for obstruction and detrusor contraction strength are less dependent on testing variations.",
keywords = "Benign prostatic hyperplasia, Contractilit́ du d́trusor, Detrusor contractility, Hypertrophie b́nigne de prostate, Obstruction uŕtrale, Urethral obstruction, Urodynamics, Urodynamique",
author = "Valentini, {F. A.} and Griffiths, {D. J.} and Zimmern, {P. E.} and Besson, {G. R.} and Nelson, {P. P.}",
year = "2005",
month = "2",
doi = "10.1016/j.annrmp.2004.06.053",
language = "French",
volume = "48",
pages = "11--19",
journal = "Annals of Physical and Rehabilitation Medicine",
issn = "1877-0657",
publisher = "Elsevier Masson",
number = "1",

}

TY - JOUR

T1 - Quantification de l'obstruction chez l'homme

T2 - Comparaison des ḿthodes usuelles avec la ḿthode VBN®

AU - Valentini, F. A.

AU - Griffiths, D. J.

AU - Zimmern, P. E.

AU - Besson, G. R.

AU - Nelson, P. P.

PY - 2005/2

Y1 - 2005/2

N2 - Goal. - To compare the merits of two methods, standard (Abrams-Griffiths number, Scḧ's classification, etc.) and VBN®, to study bladder-outlet obstruction in men with benign prostatic hyperplasia (BPH). Material and methods. - The parameters deduced from both methods and from repeated pressure-flow studies were computed for a population of patients with BPH. Correlation coefficients between standard and VBN parameters were systematically evaluated. Test-retest reliability and inter-rater reliability of the VBN parameters were investigated. Results. - The VBN obstruction parameter was linearly corelated to the A-G number (R =0.992) and thus is related to the provisional ICS obstruction nomogram. A simple modification to the standard index projected isometric pressure (PIP) yields an mPIP parameter strongly correlated with the VBN detrusor contraction-strength parameter (R =0.962). VBN analysis reveals minor phenomena such as premature fading of the detrusor contraction to be responsible for much of the void-to-void variability of pressure-flow studies. Consequently, the primary VBN obstruction and contraction-strength parameters exhibit better test-retest and inter-rater reliability than the standard parameters and are less sensitive to changes in testing circumstances (bladder volume, urethral catheter size and psychological factors). Conclusion. - With the standard approach to test bladder obstruction, two values: A-G and mPIP, derived from pressure-flow studies, best qualify the patient's voiding status. These parameters are simple to calculate but are sensitive to testing variations and minor phenomena. The VBN approach is more complicated, but its parameters for obstruction and detrusor contraction strength are less dependent on testing variations.

AB - Goal. - To compare the merits of two methods, standard (Abrams-Griffiths number, Scḧ's classification, etc.) and VBN®, to study bladder-outlet obstruction in men with benign prostatic hyperplasia (BPH). Material and methods. - The parameters deduced from both methods and from repeated pressure-flow studies were computed for a population of patients with BPH. Correlation coefficients between standard and VBN parameters were systematically evaluated. Test-retest reliability and inter-rater reliability of the VBN parameters were investigated. Results. - The VBN obstruction parameter was linearly corelated to the A-G number (R =0.992) and thus is related to the provisional ICS obstruction nomogram. A simple modification to the standard index projected isometric pressure (PIP) yields an mPIP parameter strongly correlated with the VBN detrusor contraction-strength parameter (R =0.962). VBN analysis reveals minor phenomena such as premature fading of the detrusor contraction to be responsible for much of the void-to-void variability of pressure-flow studies. Consequently, the primary VBN obstruction and contraction-strength parameters exhibit better test-retest and inter-rater reliability than the standard parameters and are less sensitive to changes in testing circumstances (bladder volume, urethral catheter size and psychological factors). Conclusion. - With the standard approach to test bladder obstruction, two values: A-G and mPIP, derived from pressure-flow studies, best qualify the patient's voiding status. These parameters are simple to calculate but are sensitive to testing variations and minor phenomena. The VBN approach is more complicated, but its parameters for obstruction and detrusor contraction strength are less dependent on testing variations.

KW - Benign prostatic hyperplasia

KW - Contractilit́ du d́trusor

KW - Detrusor contractility

KW - Hypertrophie b́nigne de prostate

KW - Obstruction uŕtrale

KW - Urethral obstruction

KW - Urodynamics

KW - Urodynamique

UR - http://www.scopus.com/inward/record.url?scp=12344333828&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12344333828&partnerID=8YFLogxK

U2 - 10.1016/j.annrmp.2004.06.053

DO - 10.1016/j.annrmp.2004.06.053

M3 - Article

C2 - 15664679

AN - SCOPUS:12344333828

VL - 48

SP - 11

EP - 19

JO - Annals of Physical and Rehabilitation Medicine

JF - Annals of Physical and Rehabilitation Medicine

SN - 1877-0657

IS - 1

ER -