Quantitative MRI assessment of a novel direction modulated brachytherapy tandem applicator for cervical cancer at 1.5 T

Abraam S. Soliman, Alyaa Elzibak, Harry Easton, James Y. Kim, Dae Yup Han, Habib Safigholi, Shahram Mashouf, Amir Owrangi, Ananth Ravi, William Y. Song

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Background and purpose The purpose of this work is to quantitatively investigate the artifacts and image distortions induced in the MR images by a recently proposed direction modulated brachytherapy (DMBT) tandem applicator prototype. This new MRI-compatible applicator allows better sparing of organs-at-risk (OAR) for cervical cancer patients, while providing conformal dose distributions to target volumes. Materials and methods Specific phantom and tools were designed and manufactured for this study. The phantom was filled with a tissue-like solution and MR images were acquired with clinical protocols as per GEC-ESTRO recommendations. Images were obtained at 6 different orientations that mimic possible clinical settings and full-width-at-half-maximum (FWHM) was recorded at multiple locations/angles. The accuracy of detecting the centerline of the tandem was assessed using a novel radial-fiducials mount. Results FWHM from all line profiles at all angles and all orientations was 6.14 ± 0.7 mm (compared to 6 mm of the actual DMBT tandem diameter). The in-plane spatial-shift observed at para-axial and para-sagittal views was less than 0.5 mm. Conclusions This work demonstrated that the novel DMBT tandem applicator prototype has minimal artifact in T2-weighted images employed in clinical practice, suggesting the applicator might be a good candidate for MRI-guided adaptive brachytherapy.

Original languageEnglish (US)
Pages (from-to)500-506
Number of pages7
JournalRadiotherapy and Oncology
Volume120
Issue number3
DOIs
StatePublished - Sep 1 2016

Fingerprint

Brachytherapy
Uterine Cervical Neoplasms
Artifacts
Organs at Risk
Clinical Protocols
Direction compound

Keywords

  • Brachytherapy
  • Cervical cancer
  • DMBT
  • MRI
  • Tandem applicator

ASJC Scopus subject areas

  • Hematology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Cite this

Quantitative MRI assessment of a novel direction modulated brachytherapy tandem applicator for cervical cancer at 1.5 T. / Soliman, Abraam S.; Elzibak, Alyaa; Easton, Harry; Kim, James Y.; Han, Dae Yup; Safigholi, Habib; Mashouf, Shahram; Owrangi, Amir; Ravi, Ananth; Song, William Y.

In: Radiotherapy and Oncology, Vol. 120, No. 3, 01.09.2016, p. 500-506.

Research output: Contribution to journalArticle

Soliman, AS, Elzibak, A, Easton, H, Kim, JY, Han, DY, Safigholi, H, Mashouf, S, Owrangi, A, Ravi, A & Song, WY 2016, 'Quantitative MRI assessment of a novel direction modulated brachytherapy tandem applicator for cervical cancer at 1.5 T', Radiotherapy and Oncology, vol. 120, no. 3, pp. 500-506. https://doi.org/10.1016/j.radonc.2016.07.006
Soliman, Abraam S. ; Elzibak, Alyaa ; Easton, Harry ; Kim, James Y. ; Han, Dae Yup ; Safigholi, Habib ; Mashouf, Shahram ; Owrangi, Amir ; Ravi, Ananth ; Song, William Y. / Quantitative MRI assessment of a novel direction modulated brachytherapy tandem applicator for cervical cancer at 1.5 T. In: Radiotherapy and Oncology. 2016 ; Vol. 120, No. 3. pp. 500-506.
@article{933f1801b05d4017b13d2160bb3d8595,
title = "Quantitative MRI assessment of a novel direction modulated brachytherapy tandem applicator for cervical cancer at 1.5 T",
abstract = "Background and purpose The purpose of this work is to quantitatively investigate the artifacts and image distortions induced in the MR images by a recently proposed direction modulated brachytherapy (DMBT) tandem applicator prototype. This new MRI-compatible applicator allows better sparing of organs-at-risk (OAR) for cervical cancer patients, while providing conformal dose distributions to target volumes. Materials and methods Specific phantom and tools were designed and manufactured for this study. The phantom was filled with a tissue-like solution and MR images were acquired with clinical protocols as per GEC-ESTRO recommendations. Images were obtained at 6 different orientations that mimic possible clinical settings and full-width-at-half-maximum (FWHM) was recorded at multiple locations/angles. The accuracy of detecting the centerline of the tandem was assessed using a novel radial-fiducials mount. Results FWHM from all line profiles at all angles and all orientations was 6.14 ± 0.7 mm (compared to 6 mm of the actual DMBT tandem diameter). The in-plane spatial-shift observed at para-axial and para-sagittal views was less than 0.5 mm. Conclusions This work demonstrated that the novel DMBT tandem applicator prototype has minimal artifact in T2-weighted images employed in clinical practice, suggesting the applicator might be a good candidate for MRI-guided adaptive brachytherapy.",
keywords = "Brachytherapy, Cervical cancer, DMBT, MRI, Tandem applicator",
author = "Soliman, {Abraam S.} and Alyaa Elzibak and Harry Easton and Kim, {James Y.} and Han, {Dae Yup} and Habib Safigholi and Shahram Mashouf and Amir Owrangi and Ananth Ravi and Song, {William Y.}",
year = "2016",
month = "9",
day = "1",
doi = "10.1016/j.radonc.2016.07.006",
language = "English (US)",
volume = "120",
pages = "500--506",
journal = "Radiotherapy and Oncology",
issn = "0167-8140",
publisher = "Elsevier Ireland Ltd",
number = "3",

}

TY - JOUR

T1 - Quantitative MRI assessment of a novel direction modulated brachytherapy tandem applicator for cervical cancer at 1.5 T

AU - Soliman, Abraam S.

AU - Elzibak, Alyaa

AU - Easton, Harry

AU - Kim, James Y.

AU - Han, Dae Yup

AU - Safigholi, Habib

AU - Mashouf, Shahram

AU - Owrangi, Amir

AU - Ravi, Ananth

AU - Song, William Y.

PY - 2016/9/1

Y1 - 2016/9/1

N2 - Background and purpose The purpose of this work is to quantitatively investigate the artifacts and image distortions induced in the MR images by a recently proposed direction modulated brachytherapy (DMBT) tandem applicator prototype. This new MRI-compatible applicator allows better sparing of organs-at-risk (OAR) for cervical cancer patients, while providing conformal dose distributions to target volumes. Materials and methods Specific phantom and tools were designed and manufactured for this study. The phantom was filled with a tissue-like solution and MR images were acquired with clinical protocols as per GEC-ESTRO recommendations. Images were obtained at 6 different orientations that mimic possible clinical settings and full-width-at-half-maximum (FWHM) was recorded at multiple locations/angles. The accuracy of detecting the centerline of the tandem was assessed using a novel radial-fiducials mount. Results FWHM from all line profiles at all angles and all orientations was 6.14 ± 0.7 mm (compared to 6 mm of the actual DMBT tandem diameter). The in-plane spatial-shift observed at para-axial and para-sagittal views was less than 0.5 mm. Conclusions This work demonstrated that the novel DMBT tandem applicator prototype has minimal artifact in T2-weighted images employed in clinical practice, suggesting the applicator might be a good candidate for MRI-guided adaptive brachytherapy.

AB - Background and purpose The purpose of this work is to quantitatively investigate the artifacts and image distortions induced in the MR images by a recently proposed direction modulated brachytherapy (DMBT) tandem applicator prototype. This new MRI-compatible applicator allows better sparing of organs-at-risk (OAR) for cervical cancer patients, while providing conformal dose distributions to target volumes. Materials and methods Specific phantom and tools were designed and manufactured for this study. The phantom was filled with a tissue-like solution and MR images were acquired with clinical protocols as per GEC-ESTRO recommendations. Images were obtained at 6 different orientations that mimic possible clinical settings and full-width-at-half-maximum (FWHM) was recorded at multiple locations/angles. The accuracy of detecting the centerline of the tandem was assessed using a novel radial-fiducials mount. Results FWHM from all line profiles at all angles and all orientations was 6.14 ± 0.7 mm (compared to 6 mm of the actual DMBT tandem diameter). The in-plane spatial-shift observed at para-axial and para-sagittal views was less than 0.5 mm. Conclusions This work demonstrated that the novel DMBT tandem applicator prototype has minimal artifact in T2-weighted images employed in clinical practice, suggesting the applicator might be a good candidate for MRI-guided adaptive brachytherapy.

KW - Brachytherapy

KW - Cervical cancer

KW - DMBT

KW - MRI

KW - Tandem applicator

UR - http://www.scopus.com/inward/record.url?scp=84992028933&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84992028933&partnerID=8YFLogxK

U2 - 10.1016/j.radonc.2016.07.006

DO - 10.1016/j.radonc.2016.07.006

M3 - Article

C2 - 27443448

AN - SCOPUS:84992028933

VL - 120

SP - 500

EP - 506

JO - Radiotherapy and Oncology

JF - Radiotherapy and Oncology

SN - 0167-8140

IS - 3

ER -