Safety of MR scanning in patients with nonferromagnetic aneurysm clips

G. Lee Pride, Janis Kowal, Dianne B. Mendelsohn, David P. Chason, James L. Fleckenstein

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

The purpose of this study was to report our surveillance of patients with nonferromagnetic aneurysm clips (NFAC) who have undergone magnetic resonance imaging (MRI). Forty-six patients with NFAC underwent MRI over a 7- year period. Medical records were studied for evidence of subjective or objective clinical findings as a result of the MRI scan. In two patients with subjective complaints, computed tomograms (CT) were reviewed and patient interviews conducted. No significant neurologic signs or long-term symptoms were experienced. Two patients did not complete their MRI scans due to transient unilateral head pain in one and head 'pressure' in another. CT scans in these patients demonstrated no evidence for hemorrhage or visible change in clip position. We documented no objective adverse outcome of patients undergoing MRI with NFAC, confirming that MRI can be performed safely in patients with nonferromagnetic aneurysm clips. The cause of subjective complaints in two of our patients is unknown. (C) 2000 Wiley-Liss, Inc.

Original languageEnglish (US)
Pages (from-to)198-200
Number of pages3
JournalJournal of Magnetic Resonance Imaging
Volume12
Issue number1
DOIs
StatePublished - Jul 2000

Fingerprint

Surgical Instruments
Aneurysm
Safety
Magnetic Resonance Imaging
Neurologic Manifestations
Medical Records
Headache
Head
Interviews
Hemorrhage
Pressure

Keywords

  • Aneurysm
  • Cerebral
  • Head
  • Iatrogenic injury
  • Magnetic resonance (MR)
  • MR
  • Radiology and radiologists
  • Safety
  • Surgery

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Safety of MR scanning in patients with nonferromagnetic aneurysm clips. / Pride, G. Lee; Kowal, Janis; Mendelsohn, Dianne B.; Chason, David P.; Fleckenstein, James L.

In: Journal of Magnetic Resonance Imaging, Vol. 12, No. 1, 07.2000, p. 198-200.

Research output: Contribution to journalArticle

@article{54544cbfb1544c4bac6e2c24e892c553,
title = "Safety of MR scanning in patients with nonferromagnetic aneurysm clips",
abstract = "The purpose of this study was to report our surveillance of patients with nonferromagnetic aneurysm clips (NFAC) who have undergone magnetic resonance imaging (MRI). Forty-six patients with NFAC underwent MRI over a 7- year period. Medical records were studied for evidence of subjective or objective clinical findings as a result of the MRI scan. In two patients with subjective complaints, computed tomograms (CT) were reviewed and patient interviews conducted. No significant neurologic signs or long-term symptoms were experienced. Two patients did not complete their MRI scans due to transient unilateral head pain in one and head 'pressure' in another. CT scans in these patients demonstrated no evidence for hemorrhage or visible change in clip position. We documented no objective adverse outcome of patients undergoing MRI with NFAC, confirming that MRI can be performed safely in patients with nonferromagnetic aneurysm clips. The cause of subjective complaints in two of our patients is unknown. (C) 2000 Wiley-Liss, Inc.",
keywords = "Aneurysm, Cerebral, Head, Iatrogenic injury, Magnetic resonance (MR), MR, Radiology and radiologists, Safety, Surgery",
author = "Pride, {G. Lee} and Janis Kowal and Mendelsohn, {Dianne B.} and Chason, {David P.} and Fleckenstein, {James L.}",
year = "2000",
month = "7",
doi = "10.1002/1522-2586(200007)12:1<198::AID-JMRI22>3.0.CO;2-T",
language = "English (US)",
volume = "12",
pages = "198--200",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Safety of MR scanning in patients with nonferromagnetic aneurysm clips

AU - Pride, G. Lee

AU - Kowal, Janis

AU - Mendelsohn, Dianne B.

AU - Chason, David P.

AU - Fleckenstein, James L.

PY - 2000/7

Y1 - 2000/7

N2 - The purpose of this study was to report our surveillance of patients with nonferromagnetic aneurysm clips (NFAC) who have undergone magnetic resonance imaging (MRI). Forty-six patients with NFAC underwent MRI over a 7- year period. Medical records were studied for evidence of subjective or objective clinical findings as a result of the MRI scan. In two patients with subjective complaints, computed tomograms (CT) were reviewed and patient interviews conducted. No significant neurologic signs or long-term symptoms were experienced. Two patients did not complete their MRI scans due to transient unilateral head pain in one and head 'pressure' in another. CT scans in these patients demonstrated no evidence for hemorrhage or visible change in clip position. We documented no objective adverse outcome of patients undergoing MRI with NFAC, confirming that MRI can be performed safely in patients with nonferromagnetic aneurysm clips. The cause of subjective complaints in two of our patients is unknown. (C) 2000 Wiley-Liss, Inc.

AB - The purpose of this study was to report our surveillance of patients with nonferromagnetic aneurysm clips (NFAC) who have undergone magnetic resonance imaging (MRI). Forty-six patients with NFAC underwent MRI over a 7- year period. Medical records were studied for evidence of subjective or objective clinical findings as a result of the MRI scan. In two patients with subjective complaints, computed tomograms (CT) were reviewed and patient interviews conducted. No significant neurologic signs or long-term symptoms were experienced. Two patients did not complete their MRI scans due to transient unilateral head pain in one and head 'pressure' in another. CT scans in these patients demonstrated no evidence for hemorrhage or visible change in clip position. We documented no objective adverse outcome of patients undergoing MRI with NFAC, confirming that MRI can be performed safely in patients with nonferromagnetic aneurysm clips. The cause of subjective complaints in two of our patients is unknown. (C) 2000 Wiley-Liss, Inc.

KW - Aneurysm

KW - Cerebral

KW - Head

KW - Iatrogenic injury

KW - Magnetic resonance (MR)

KW - MR

KW - Radiology and radiologists

KW - Safety

KW - Surgery

UR - http://www.scopus.com/inward/record.url?scp=0033932711&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033932711&partnerID=8YFLogxK

U2 - 10.1002/1522-2586(200007)12:1<198::AID-JMRI22>3.0.CO;2-T

DO - 10.1002/1522-2586(200007)12:1<198::AID-JMRI22>3.0.CO;2-T

M3 - Article

C2 - 10931580

AN - SCOPUS:0033932711

VL - 12

SP - 198

EP - 200

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 1

ER -