Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

Thad E. Wilson, Jian Cui, Rong Zhang, Sarah Witkowski, Craig G. Crandall

Research output: Contribution to journalArticle

95 Citations (Scopus)

Abstract

Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60° head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt cool), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt cool). Heating and cooling were accomplished by perfusing 46 and 15°C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt cool, or HT-tilt cool. During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt cool, MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

Original languageEnglish (US)
Pages (from-to)85-91
Number of pages7
JournalJournal of Applied Physiology
Volume93
Issue number1
StatePublished - 2002

Fingerprint

Cerebrovascular Circulation
Blood Flow Velocity
Arterial Pressure
Skin
Hot Temperature
Vascular Resistance
Orthostatic Intolerance
Heating
Head
Maintenance
Water

Keywords

  • Heat stress
  • Hyperthermia
  • Syncope
  • Transcranial Doppler

ASJC Scopus subject areas

  • Physiology
  • Endocrinology
  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans. / Wilson, Thad E.; Cui, Jian; Zhang, Rong; Witkowski, Sarah; Crandall, Craig G.

In: Journal of Applied Physiology, Vol. 93, No. 1, 2002, p. 85-91.

Research output: Contribution to journalArticle

@article{414b4a9cf54b4b8baff89b23d116f6de,
title = "Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans",
abstract = "Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60° head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt cool), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt cool). Heating and cooling were accomplished by perfusing 46 and 15°C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt cool, or HT-tilt cool. During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt cool, MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.",
keywords = "Heat stress, Hyperthermia, Syncope, Transcranial Doppler",
author = "Wilson, {Thad E.} and Jian Cui and Rong Zhang and Sarah Witkowski and Crandall, {Craig G.}",
year = "2002",
language = "English (US)",
volume = "93",
pages = "85--91",
journal = "Journal of Applied Physiology",
issn = "0161-7567",
publisher = "American Physiological Society",
number = "1",

}

TY - JOUR

T1 - Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

AU - Wilson, Thad E.

AU - Cui, Jian

AU - Zhang, Rong

AU - Witkowski, Sarah

AU - Crandall, Craig G.

PY - 2002

Y1 - 2002

N2 - Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60° head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt cool), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt cool). Heating and cooling were accomplished by perfusing 46 and 15°C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt cool, or HT-tilt cool. During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt cool, MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

AB - Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60° head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt cool), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt cool). Heating and cooling were accomplished by perfusing 46 and 15°C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt cool, or HT-tilt cool. During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt cool, MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

KW - Heat stress

KW - Hyperthermia

KW - Syncope

KW - Transcranial Doppler

UR - http://www.scopus.com/inward/record.url?scp=0035985907&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035985907&partnerID=8YFLogxK

M3 - Article

VL - 93

SP - 85

EP - 91

JO - Journal of Applied Physiology

JF - Journal of Applied Physiology

SN - 0161-7567

IS - 1

ER -