Stereoscopic interpretation of low-dose breast tomosynthesis projection images

Gautam S. Muralidhar, Mia K. Markey, Alan C. Bovik, Tamara Miner Haygood, Tanya W. Stephens, William R. Geiser, Naveen Garg, Beatriz E. Adrada, Basak E. Dogan, Selin Carkaci, Raunak Khisty, Gary J. Whitman

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed. A stereoscopic pair comprised of two projection images that were ±4 apart from the zero angle projection was displayed on a Planar PL2010M stereoscopic display (Planar Systems, Inc., Beaverton, OR, USA). An experienced breast imager verified the truth for each case stereoscopically. A two-phase blinded observer study was conducted. In the first phase, two experienced breast imagers rated their ability to perceive 3D information using a scale of 1-3 and described the most suspicious lesion using the BI-RADS® descriptors. In the second phase, four experienced breast imagers were asked to make a binary decision on whether they saw a mass for which they would initiate a diagnostic workup or not and also report the location of the mass and provide a confidence score in the range of 0-100. The sensitivity and the specificity of the lesion detection task were evaluated. The results from our study suggest that radiologists who can perceive stereo can reliably interpret breast tomosynthesis projection images using stereoscopic viewing.

Original languageEnglish (US)
Pages (from-to)248-254
Number of pages7
JournalJournal of Digital Imaging
Volume27
Issue number2
DOIs
StatePublished - Jan 1 2014

Fingerprint

Image sensors
Breast
Biopsy
Display devices
Aptitude
Research Ethics Committees
Sensitivity and Specificity

Keywords

  • 3D perception
  • Breast tomosynthesis
  • Low-dose projections
  • Stereoscopic display

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology
  • Computer Science Applications

Cite this

Muralidhar, G. S., Markey, M. K., Bovik, A. C., Haygood, T. M., Stephens, T. W., Geiser, W. R., ... Whitman, G. J. (2014). Stereoscopic interpretation of low-dose breast tomosynthesis projection images. Journal of Digital Imaging, 27(2), 248-254. https://doi.org/10.1007/s10278-013-9648-x

Stereoscopic interpretation of low-dose breast tomosynthesis projection images. / Muralidhar, Gautam S.; Markey, Mia K.; Bovik, Alan C.; Haygood, Tamara Miner; Stephens, Tanya W.; Geiser, William R.; Garg, Naveen; Adrada, Beatriz E.; Dogan, Basak E.; Carkaci, Selin; Khisty, Raunak; Whitman, Gary J.

In: Journal of Digital Imaging, Vol. 27, No. 2, 01.01.2014, p. 248-254.

Research output: Contribution to journalArticle

Muralidhar, GS, Markey, MK, Bovik, AC, Haygood, TM, Stephens, TW, Geiser, WR, Garg, N, Adrada, BE, Dogan, BE, Carkaci, S, Khisty, R & Whitman, GJ 2014, 'Stereoscopic interpretation of low-dose breast tomosynthesis projection images', Journal of Digital Imaging, vol. 27, no. 2, pp. 248-254. https://doi.org/10.1007/s10278-013-9648-x
Muralidhar GS, Markey MK, Bovik AC, Haygood TM, Stephens TW, Geiser WR et al. Stereoscopic interpretation of low-dose breast tomosynthesis projection images. Journal of Digital Imaging. 2014 Jan 1;27(2):248-254. https://doi.org/10.1007/s10278-013-9648-x
Muralidhar, Gautam S. ; Markey, Mia K. ; Bovik, Alan C. ; Haygood, Tamara Miner ; Stephens, Tanya W. ; Geiser, William R. ; Garg, Naveen ; Adrada, Beatriz E. ; Dogan, Basak E. ; Carkaci, Selin ; Khisty, Raunak ; Whitman, Gary J. / Stereoscopic interpretation of low-dose breast tomosynthesis projection images. In: Journal of Digital Imaging. 2014 ; Vol. 27, No. 2. pp. 248-254.
@article{a726ea582bef4b8db30057b0f16ff088,
title = "Stereoscopic interpretation of low-dose breast tomosynthesis projection images",
abstract = "The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed. A stereoscopic pair comprised of two projection images that were ±4 apart from the zero angle projection was displayed on a Planar PL2010M stereoscopic display (Planar Systems, Inc., Beaverton, OR, USA). An experienced breast imager verified the truth for each case stereoscopically. A two-phase blinded observer study was conducted. In the first phase, two experienced breast imagers rated their ability to perceive 3D information using a scale of 1-3 and described the most suspicious lesion using the BI-RADS{\circledR} descriptors. In the second phase, four experienced breast imagers were asked to make a binary decision on whether they saw a mass for which they would initiate a diagnostic workup or not and also report the location of the mass and provide a confidence score in the range of 0-100. The sensitivity and the specificity of the lesion detection task were evaluated. The results from our study suggest that radiologists who can perceive stereo can reliably interpret breast tomosynthesis projection images using stereoscopic viewing.",
keywords = "3D perception, Breast tomosynthesis, Low-dose projections, Stereoscopic display",
author = "Muralidhar, {Gautam S.} and Markey, {Mia K.} and Bovik, {Alan C.} and Haygood, {Tamara Miner} and Stephens, {Tanya W.} and Geiser, {William R.} and Naveen Garg and Adrada, {Beatriz E.} and Dogan, {Basak E.} and Selin Carkaci and Raunak Khisty and Whitman, {Gary J.}",
year = "2014",
month = "1",
day = "1",
doi = "10.1007/s10278-013-9648-x",
language = "English (US)",
volume = "27",
pages = "248--254",
journal = "Journal of Digital Imaging",
issn = "0897-1889",
publisher = "Springer New York",
number = "2",

}

TY - JOUR

T1 - Stereoscopic interpretation of low-dose breast tomosynthesis projection images

AU - Muralidhar, Gautam S.

AU - Markey, Mia K.

AU - Bovik, Alan C.

AU - Haygood, Tamara Miner

AU - Stephens, Tanya W.

AU - Geiser, William R.

AU - Garg, Naveen

AU - Adrada, Beatriz E.

AU - Dogan, Basak E.

AU - Carkaci, Selin

AU - Khisty, Raunak

AU - Whitman, Gary J.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed. A stereoscopic pair comprised of two projection images that were ±4 apart from the zero angle projection was displayed on a Planar PL2010M stereoscopic display (Planar Systems, Inc., Beaverton, OR, USA). An experienced breast imager verified the truth for each case stereoscopically. A two-phase blinded observer study was conducted. In the first phase, two experienced breast imagers rated their ability to perceive 3D information using a scale of 1-3 and described the most suspicious lesion using the BI-RADS® descriptors. In the second phase, four experienced breast imagers were asked to make a binary decision on whether they saw a mass for which they would initiate a diagnostic workup or not and also report the location of the mass and provide a confidence score in the range of 0-100. The sensitivity and the specificity of the lesion detection task were evaluated. The results from our study suggest that radiologists who can perceive stereo can reliably interpret breast tomosynthesis projection images using stereoscopic viewing.

AB - The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed. A stereoscopic pair comprised of two projection images that were ±4 apart from the zero angle projection was displayed on a Planar PL2010M stereoscopic display (Planar Systems, Inc., Beaverton, OR, USA). An experienced breast imager verified the truth for each case stereoscopically. A two-phase blinded observer study was conducted. In the first phase, two experienced breast imagers rated their ability to perceive 3D information using a scale of 1-3 and described the most suspicious lesion using the BI-RADS® descriptors. In the second phase, four experienced breast imagers were asked to make a binary decision on whether they saw a mass for which they would initiate a diagnostic workup or not and also report the location of the mass and provide a confidence score in the range of 0-100. The sensitivity and the specificity of the lesion detection task were evaluated. The results from our study suggest that radiologists who can perceive stereo can reliably interpret breast tomosynthesis projection images using stereoscopic viewing.

KW - 3D perception

KW - Breast tomosynthesis

KW - Low-dose projections

KW - Stereoscopic display

UR - http://www.scopus.com/inward/record.url?scp=84897023740&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84897023740&partnerID=8YFLogxK

U2 - 10.1007/s10278-013-9648-x

DO - 10.1007/s10278-013-9648-x

M3 - Article

VL - 27

SP - 248

EP - 254

JO - Journal of Digital Imaging

JF - Journal of Digital Imaging

SN - 0897-1889

IS - 2

ER -