SU‐E‐T‐21: Modeling a MLC Scatter Source for In‐Air Output Factors

S. Park, S. Kim, Y. Park, J. Park, J. Kim, H. Kim, C. Choi, S. ye

Research output: Contribution to journalArticle

Abstract

Purpose: Scattered radiation from multi‐leaf collimators (MLCs) is no longer negligible for calculating in‐air output ratio, Sc for small and irregular fields often used in intensity‐modulated radiation therapy (IMRT). An extra‐focal source model for scattered radiation from MLCs, namely MLC scatter source, has been developed to improve the accuracy of the Sc calculation. Methods: A conventional dual‐source model was made by using Sc data that were measured for collimator‐defined fields of Varian Clinac IX linear accelerator. Then, an MLC scatter source at the center of the MLC position of the linear accelerator was assumed in the model. The MLC scatter source model consisted of two Gaussian functions of which parameters were iteratively optimized against the Sc data measured for different MLC fields with fixed collimator sizes. To evaluate the effectiveness of the developed source model, measurements were made for various MLC‐defined irregular or square fields. The calculated Sc data by using (1) the developed source model and (2) the conventional dual source model were compared with the measured data. Results: The mean discrepancy between the measured Sc and calculated Sc from the developed source model was 0.08+‐0.28%, while one from the conventional source model was 0.44+−0.39%. Conclusions: The developed MLC scatter source model in conjunction with the dual source model could improve the accuracy of the Sc calculation in IMRT fields.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume39
Issue number6
DOIs
StatePublished - Jan 1 2012

Fingerprint

Particle Accelerators
Radiotherapy
Radiation

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐E‐T‐21 : Modeling a MLC Scatter Source for In‐Air Output Factors. / Park, S.; Kim, S.; Park, Y.; Park, J.; Kim, J.; Kim, H.; Choi, C.; ye, S.

In: Medical Physics, Vol. 39, No. 6, 01.01.2012.

Research output: Contribution to journalArticle

Park, S. ; Kim, S. ; Park, Y. ; Park, J. ; Kim, J. ; Kim, H. ; Choi, C. ; ye, S. / SU‐E‐T‐21 : Modeling a MLC Scatter Source for In‐Air Output Factors. In: Medical Physics. 2012 ; Vol. 39, No. 6.
@article{4766df37e41843ab8973f0e150f2b480,
title = "SU‐E‐T‐21: Modeling a MLC Scatter Source for In‐Air Output Factors",
abstract = "Purpose: Scattered radiation from multi‐leaf collimators (MLCs) is no longer negligible for calculating in‐air output ratio, Sc for small and irregular fields often used in intensity‐modulated radiation therapy (IMRT). An extra‐focal source model for scattered radiation from MLCs, namely MLC scatter source, has been developed to improve the accuracy of the Sc calculation. Methods: A conventional dual‐source model was made by using Sc data that were measured for collimator‐defined fields of Varian Clinac IX linear accelerator. Then, an MLC scatter source at the center of the MLC position of the linear accelerator was assumed in the model. The MLC scatter source model consisted of two Gaussian functions of which parameters were iteratively optimized against the Sc data measured for different MLC fields with fixed collimator sizes. To evaluate the effectiveness of the developed source model, measurements were made for various MLC‐defined irregular or square fields. The calculated Sc data by using (1) the developed source model and (2) the conventional dual source model were compared with the measured data. Results: The mean discrepancy between the measured Sc and calculated Sc from the developed source model was 0.08+‐0.28{\%}, while one from the conventional source model was 0.44+−0.39{\%}. Conclusions: The developed MLC scatter source model in conjunction with the dual source model could improve the accuracy of the Sc calculation in IMRT fields.",
author = "S. Park and S. Kim and Y. Park and J. Park and J. Kim and H. Kim and C. Choi and S. ye",
year = "2012",
month = "1",
day = "1",
doi = "10.1118/1.4735075",
language = "English (US)",
volume = "39",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐E‐T‐21

T2 - Modeling a MLC Scatter Source for In‐Air Output Factors

AU - Park, S.

AU - Kim, S.

AU - Park, Y.

AU - Park, J.

AU - Kim, J.

AU - Kim, H.

AU - Choi, C.

AU - ye, S.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Purpose: Scattered radiation from multi‐leaf collimators (MLCs) is no longer negligible for calculating in‐air output ratio, Sc for small and irregular fields often used in intensity‐modulated radiation therapy (IMRT). An extra‐focal source model for scattered radiation from MLCs, namely MLC scatter source, has been developed to improve the accuracy of the Sc calculation. Methods: A conventional dual‐source model was made by using Sc data that were measured for collimator‐defined fields of Varian Clinac IX linear accelerator. Then, an MLC scatter source at the center of the MLC position of the linear accelerator was assumed in the model. The MLC scatter source model consisted of two Gaussian functions of which parameters were iteratively optimized against the Sc data measured for different MLC fields with fixed collimator sizes. To evaluate the effectiveness of the developed source model, measurements were made for various MLC‐defined irregular or square fields. The calculated Sc data by using (1) the developed source model and (2) the conventional dual source model were compared with the measured data. Results: The mean discrepancy between the measured Sc and calculated Sc from the developed source model was 0.08+‐0.28%, while one from the conventional source model was 0.44+−0.39%. Conclusions: The developed MLC scatter source model in conjunction with the dual source model could improve the accuracy of the Sc calculation in IMRT fields.

AB - Purpose: Scattered radiation from multi‐leaf collimators (MLCs) is no longer negligible for calculating in‐air output ratio, Sc for small and irregular fields often used in intensity‐modulated radiation therapy (IMRT). An extra‐focal source model for scattered radiation from MLCs, namely MLC scatter source, has been developed to improve the accuracy of the Sc calculation. Methods: A conventional dual‐source model was made by using Sc data that were measured for collimator‐defined fields of Varian Clinac IX linear accelerator. Then, an MLC scatter source at the center of the MLC position of the linear accelerator was assumed in the model. The MLC scatter source model consisted of two Gaussian functions of which parameters were iteratively optimized against the Sc data measured for different MLC fields with fixed collimator sizes. To evaluate the effectiveness of the developed source model, measurements were made for various MLC‐defined irregular or square fields. The calculated Sc data by using (1) the developed source model and (2) the conventional dual source model were compared with the measured data. Results: The mean discrepancy between the measured Sc and calculated Sc from the developed source model was 0.08+‐0.28%, while one from the conventional source model was 0.44+−0.39%. Conclusions: The developed MLC scatter source model in conjunction with the dual source model could improve the accuracy of the Sc calculation in IMRT fields.

UR - http://www.scopus.com/inward/record.url?scp=85024808523&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024808523&partnerID=8YFLogxK

U2 - 10.1118/1.4735075

DO - 10.1118/1.4735075

M3 - Article

C2 - 28519061

AN - SCOPUS:85024808523

VL - 39

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -