Purpose: Microcalcifications (MCs) play an important role in early detection of breast cancer. This study is to describe a technique to automatically identify and segment the calcifications from the breast anatomy in cone beam CT (CBCT) images. Method and Materials: Projection images of mastectomy breast specimens were acquired with a bench‐top experimental CBCT system and reconstructed using FDK algorithm with a regular ramp filter. The reconstructed images were first corrected for the non‐uniform cupping artifacts due to x‐ray scatter and beam hardening. The corrected CBCT images had more uniform background but were still too noisy for threshold segmentation. To reduce the noise level, the images were processed with a noise averaging filter in z direction followed by a total variation filter to reduce the noise level while keeping the edge sharpness and contrast of calcifications. To automatically detect the calcifications with proper threshold level, a Gaussian curve fitting was used to fit the histogram of the CBCT image. Since the CT numbers of calcifications are usually significantly above those for breast tissue, cutoff point of the Gaussian curve was used as the threshold value to segment the calcifications. Results: With this method, the calcifications in the entire breast were successfully segmented from the breast tissue background. The results agreed well with those identified by visualization. Conclusion: The calcifications in CBCT breast images can be automatically detected by threshold based segmentation method with the nonuniform cupping artifacts corrected for and the noise level properly reduced.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume36
Issue number6
DOIs
StatePublished - Jan 1 2009

Fingerprint

Breast
Cone-Beam Computed Tomography
Noise
Artifacts
Calcinosis
Architectural Accessibility
Mastectomy
Early Detection of Cancer
Anatomy
X-Rays
Breast Neoplasms

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Han, T., Chen, L., Zhong, Y., Lai, C., Liu, X., Shen, Y., ... Shaw, C. (2009). SU‐FF‐I‐26: Automatic Detection of Calcifications in Cone Beam Breast CT Images. Medical Physics, 36(6). https://doi.org/10.1118/1.3181145

SU‐FF‐I‐26 : Automatic Detection of Calcifications in Cone Beam Breast CT Images. / Han, T.; Chen, L.; Zhong, Y.; Lai, C.; Liu, X.; Shen, Y.; Yi, Y.; Ge, S.; You, Z.; Wang, T.; Shaw, C.

In: Medical Physics, Vol. 36, No. 6, 01.01.2009.

Research output: Contribution to journalArticle

Han, T, Chen, L, Zhong, Y, Lai, C, Liu, X, Shen, Y, Yi, Y, Ge, S, You, Z, Wang, T & Shaw, C 2009, 'SU‐FF‐I‐26: Automatic Detection of Calcifications in Cone Beam Breast CT Images', Medical Physics, vol. 36, no. 6. https://doi.org/10.1118/1.3181145
Han, T. ; Chen, L. ; Zhong, Y. ; Lai, C. ; Liu, X. ; Shen, Y. ; Yi, Y. ; Ge, S. ; You, Z. ; Wang, T. ; Shaw, C. / SU‐FF‐I‐26 : Automatic Detection of Calcifications in Cone Beam Breast CT Images. In: Medical Physics. 2009 ; Vol. 36, No. 6.
@article{ed93b7221d254004bcbdfc6e34f7c9e4,
title = "SU‐FF‐I‐26: Automatic Detection of Calcifications in Cone Beam Breast CT Images",
abstract = "Purpose: Microcalcifications (MCs) play an important role in early detection of breast cancer. This study is to describe a technique to automatically identify and segment the calcifications from the breast anatomy in cone beam CT (CBCT) images. Method and Materials: Projection images of mastectomy breast specimens were acquired with a bench‐top experimental CBCT system and reconstructed using FDK algorithm with a regular ramp filter. The reconstructed images were first corrected for the non‐uniform cupping artifacts due to x‐ray scatter and beam hardening. The corrected CBCT images had more uniform background but were still too noisy for threshold segmentation. To reduce the noise level, the images were processed with a noise averaging filter in z direction followed by a total variation filter to reduce the noise level while keeping the edge sharpness and contrast of calcifications. To automatically detect the calcifications with proper threshold level, a Gaussian curve fitting was used to fit the histogram of the CBCT image. Since the CT numbers of calcifications are usually significantly above those for breast tissue, cutoff point of the Gaussian curve was used as the threshold value to segment the calcifications. Results: With this method, the calcifications in the entire breast were successfully segmented from the breast tissue background. The results agreed well with those identified by visualization. Conclusion: The calcifications in CBCT breast images can be automatically detected by threshold based segmentation method with the nonuniform cupping artifacts corrected for and the noise level properly reduced.",
author = "T. Han and L. Chen and Y. Zhong and C. Lai and X. Liu and Y. Shen and Y. Yi and S. Ge and Z. You and T. Wang and C. Shaw",
year = "2009",
month = "1",
day = "1",
doi = "10.1118/1.3181145",
language = "English (US)",
volume = "36",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐FF‐I‐26

T2 - Automatic Detection of Calcifications in Cone Beam Breast CT Images

AU - Han, T.

AU - Chen, L.

AU - Zhong, Y.

AU - Lai, C.

AU - Liu, X.

AU - Shen, Y.

AU - Yi, Y.

AU - Ge, S.

AU - You, Z.

AU - Wang, T.

AU - Shaw, C.

PY - 2009/1/1

Y1 - 2009/1/1

N2 - Purpose: Microcalcifications (MCs) play an important role in early detection of breast cancer. This study is to describe a technique to automatically identify and segment the calcifications from the breast anatomy in cone beam CT (CBCT) images. Method and Materials: Projection images of mastectomy breast specimens were acquired with a bench‐top experimental CBCT system and reconstructed using FDK algorithm with a regular ramp filter. The reconstructed images were first corrected for the non‐uniform cupping artifacts due to x‐ray scatter and beam hardening. The corrected CBCT images had more uniform background but were still too noisy for threshold segmentation. To reduce the noise level, the images were processed with a noise averaging filter in z direction followed by a total variation filter to reduce the noise level while keeping the edge sharpness and contrast of calcifications. To automatically detect the calcifications with proper threshold level, a Gaussian curve fitting was used to fit the histogram of the CBCT image. Since the CT numbers of calcifications are usually significantly above those for breast tissue, cutoff point of the Gaussian curve was used as the threshold value to segment the calcifications. Results: With this method, the calcifications in the entire breast were successfully segmented from the breast tissue background. The results agreed well with those identified by visualization. Conclusion: The calcifications in CBCT breast images can be automatically detected by threshold based segmentation method with the nonuniform cupping artifacts corrected for and the noise level properly reduced.

AB - Purpose: Microcalcifications (MCs) play an important role in early detection of breast cancer. This study is to describe a technique to automatically identify and segment the calcifications from the breast anatomy in cone beam CT (CBCT) images. Method and Materials: Projection images of mastectomy breast specimens were acquired with a bench‐top experimental CBCT system and reconstructed using FDK algorithm with a regular ramp filter. The reconstructed images were first corrected for the non‐uniform cupping artifacts due to x‐ray scatter and beam hardening. The corrected CBCT images had more uniform background but were still too noisy for threshold segmentation. To reduce the noise level, the images were processed with a noise averaging filter in z direction followed by a total variation filter to reduce the noise level while keeping the edge sharpness and contrast of calcifications. To automatically detect the calcifications with proper threshold level, a Gaussian curve fitting was used to fit the histogram of the CBCT image. Since the CT numbers of calcifications are usually significantly above those for breast tissue, cutoff point of the Gaussian curve was used as the threshold value to segment the calcifications. Results: With this method, the calcifications in the entire breast were successfully segmented from the breast tissue background. The results agreed well with those identified by visualization. Conclusion: The calcifications in CBCT breast images can be automatically detected by threshold based segmentation method with the nonuniform cupping artifacts corrected for and the noise level properly reduced.

UR - http://www.scopus.com/inward/record.url?scp=85024811943&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024811943&partnerID=8YFLogxK

U2 - 10.1118/1.3181145

DO - 10.1118/1.3181145

M3 - Article

AN - SCOPUS:85024811943

VL - 36

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -