Purpose: Ascertain effects of mammographic compression on microvascular blood flow and thus understand potential confounding factors due to compression on contrast agent distribution. Method and Materials: An X‐ray mammogram simulator was constructed to hold optical fibers for diffuse correlation spectroscopy measurements of blood flow and diffuse optical spectroscopy measurements of hemoglobin concentration and oxygenation. 15 healthy subjects were recruited for experiments consisting of 3 serial compression‐release cycles. Results: Small (∼15% or ∼1cm) changes in plate separation resulted in dramatic changes in blood volume (∼47%) and flow (∼65%) in measurements of 15 subjects. However, there was significant inter‐ and intra‐ subject variation in response within the population. Conclusion: The distribution of contrast agents injected during mammographic compression will be affected by the average and inhomogeneous changes in blood flow measured in this study. This study is currently being expanded and instrumentation improved to identify the cause of inter‐subject variation in blood flow changes.

Original languageEnglish (US)
Number of pages1
JournalMedical physics
Volume37
Issue number6
DOIs
StatePublished - Jun 2010
Externally publishedYes

Fingerprint

Mammography
Blood Volume
Contrast Media
Spectrum Analysis
Optical Fibers
Healthy Volunteers
Hemoglobins
X-Rays
Population

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Busch, D. R., Minkoff, D. L., Choe, R., Durduran, T., Schnall, M. D., Rosen, M. A., & Yodh, A. G. (2010). SU‐HH‐BRB‐08: Blood Flow and Volume Changes during Simulated Mammography. Medical physics, 37(6). https://doi.org/10.1118/1.3469026

SU‐HH‐BRB‐08 : Blood Flow and Volume Changes during Simulated Mammography. / Busch, D. R.; Minkoff, D. L.; Choe, R.; Durduran, T.; Schnall, M. D.; Rosen, M. A.; Yodh, A. G.

In: Medical physics, Vol. 37, No. 6, 06.2010.

Research output: Contribution to journalArticle

Busch, DR, Minkoff, DL, Choe, R, Durduran, T, Schnall, MD, Rosen, MA & Yodh, AG 2010, 'SU‐HH‐BRB‐08: Blood Flow and Volume Changes during Simulated Mammography', Medical physics, vol. 37, no. 6. https://doi.org/10.1118/1.3469026
Busch, D. R. ; Minkoff, D. L. ; Choe, R. ; Durduran, T. ; Schnall, M. D. ; Rosen, M. A. ; Yodh, A. G. / SU‐HH‐BRB‐08 : Blood Flow and Volume Changes during Simulated Mammography. In: Medical physics. 2010 ; Vol. 37, No. 6.
@article{bc8b6a7996364304807b158b5d871473,
title = "SU‐HH‐BRB‐08: Blood Flow and Volume Changes during Simulated Mammography",
abstract = "Purpose: Ascertain effects of mammographic compression on microvascular blood flow and thus understand potential confounding factors due to compression on contrast agent distribution. Method and Materials: An X‐ray mammogram simulator was constructed to hold optical fibers for diffuse correlation spectroscopy measurements of blood flow and diffuse optical spectroscopy measurements of hemoglobin concentration and oxygenation. 15 healthy subjects were recruited for experiments consisting of 3 serial compression‐release cycles. Results: Small (∼15{\%} or ∼1cm) changes in plate separation resulted in dramatic changes in blood volume (∼47{\%}) and flow (∼65{\%}) in measurements of 15 subjects. However, there was significant inter‐ and intra‐ subject variation in response within the population. Conclusion: The distribution of contrast agents injected during mammographic compression will be affected by the average and inhomogeneous changes in blood flow measured in this study. This study is currently being expanded and instrumentation improved to identify the cause of inter‐subject variation in blood flow changes.",
author = "Busch, {D. R.} and Minkoff, {D. L.} and R. Choe and T. Durduran and Schnall, {M. D.} and Rosen, {M. A.} and Yodh, {A. G.}",
year = "2010",
month = "6",
doi = "10.1118/1.3469026",
language = "English (US)",
volume = "37",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐HH‐BRB‐08

T2 - Blood Flow and Volume Changes during Simulated Mammography

AU - Busch, D. R.

AU - Minkoff, D. L.

AU - Choe, R.

AU - Durduran, T.

AU - Schnall, M. D.

AU - Rosen, M. A.

AU - Yodh, A. G.

PY - 2010/6

Y1 - 2010/6

N2 - Purpose: Ascertain effects of mammographic compression on microvascular blood flow and thus understand potential confounding factors due to compression on contrast agent distribution. Method and Materials: An X‐ray mammogram simulator was constructed to hold optical fibers for diffuse correlation spectroscopy measurements of blood flow and diffuse optical spectroscopy measurements of hemoglobin concentration and oxygenation. 15 healthy subjects were recruited for experiments consisting of 3 serial compression‐release cycles. Results: Small (∼15% or ∼1cm) changes in plate separation resulted in dramatic changes in blood volume (∼47%) and flow (∼65%) in measurements of 15 subjects. However, there was significant inter‐ and intra‐ subject variation in response within the population. Conclusion: The distribution of contrast agents injected during mammographic compression will be affected by the average and inhomogeneous changes in blood flow measured in this study. This study is currently being expanded and instrumentation improved to identify the cause of inter‐subject variation in blood flow changes.

AB - Purpose: Ascertain effects of mammographic compression on microvascular blood flow and thus understand potential confounding factors due to compression on contrast agent distribution. Method and Materials: An X‐ray mammogram simulator was constructed to hold optical fibers for diffuse correlation spectroscopy measurements of blood flow and diffuse optical spectroscopy measurements of hemoglobin concentration and oxygenation. 15 healthy subjects were recruited for experiments consisting of 3 serial compression‐release cycles. Results: Small (∼15% or ∼1cm) changes in plate separation resulted in dramatic changes in blood volume (∼47%) and flow (∼65%) in measurements of 15 subjects. However, there was significant inter‐ and intra‐ subject variation in response within the population. Conclusion: The distribution of contrast agents injected during mammographic compression will be affected by the average and inhomogeneous changes in blood flow measured in this study. This study is currently being expanded and instrumentation improved to identify the cause of inter‐subject variation in blood flow changes.

UR - http://www.scopus.com/inward/record.url?scp=84890698021&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890698021&partnerID=8YFLogxK

U2 - 10.1118/1.3469026

DO - 10.1118/1.3469026

M3 - Article

AN - SCOPUS:84890698021

VL - 37

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -