N2 - Evaluating tumor microvascular networks with use of contrast-enhanced ultrasound (CEUS) imaging and one-dimensional (1D) linear array transducers have inherit limitations as tumors exist in volume space. The use of a mechanical sweep allows users to overcome this limitation. To that end, we have developed a new method by which a 1D linear array transducer can be mechanically scanned over a region-of-interest to capture a volume of data allowing for the evaluation of microvasculature structures in 3D space. After intravascular injection of a microbubble (MB) contrast agent into a developing chicken embryo, a sequence of CEUS images were acquired using a Vevo 3100 scanner (VisualSonics Inc) and taken at multiple tissue cross-sections. The CEUS images were processed with a singular value filter (SVF) to help remove any clutter signal. MB localization was performed, and frame-to-frame MB movement was analyzed to produce spatial maps depicting blood flow and velocity at each tissue cross-section. Reconstruction of all images allowed visualization of microvascular networks and blood velocity distribution in volume space.
AB - Evaluating tumor microvascular networks with use of contrast-enhanced ultrasound (CEUS) imaging and one-dimensional (1D) linear array transducers have inherit limitations as tumors exist in volume space. The use of a mechanical sweep allows users to overcome this limitation. To that end, we have developed a new method by which a 1D linear array transducer can be mechanically scanned over a region-of-interest to capture a volume of data allowing for the evaluation of microvasculature structures in 3D space. After intravascular injection of a microbubble (MB) contrast agent into a developing chicken embryo, a sequence of CEUS images were acquired using a Vevo 3100 scanner (VisualSonics Inc) and taken at multiple tissue cross-sections. The CEUS images were processed with a singular value filter (SVF) to help remove any clutter signal. MB localization was performed, and frame-to-frame MB movement was analyzed to produce spatial maps depicting blood flow and velocity at each tissue cross-section. Reconstruction of all images allowed visualization of microvascular networks and blood velocity distribution in volume space.
KW - Contrast agent
KW - Contrast-enhanced ultrasound
KW - Microbubbles
KW - Microvascular networks
KW - Ultrasound
KW - Volume imaging
UR - http://www.scopus.com/inward/record.url?scp=85097869264&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85097869264&partnerID=8YFLogxK
U2 - 10.1109/IUS46767.2020.9251525
DO - 10.1109/IUS46767.2020.9251525
M3 - Conference contribution
AN - SCOPUS:85097869264
T3 - IEEE International Ultrasonics Symposium, IUS
BT - IUS 2020 - International Ultrasonics Symposium, Proceedings
PB - IEEE Computer Society
T2 - 2020 IEEE International Ultrasonics Symposium, IUS 2020
Y2 - 7 September 2020 through 11 September 2020
ER -