WE‐D‐BRA‐01: Stereotactic Body Radiotherapy (SBRT): Technical and Clinical Considerations

B. Kavanagh, I. J. Chetty, J. M. Balter, T. D. Solberg

Research output: Contribution to journalArticle

Abstract

Stereotactic Body Radiotherapy (SBRT) has now been applied clinically for more than a decade. The accumulation of published technical and clinical studies currently available has offered insights into both the efficacy and special concerns associated with the delivery of SBRT to different sites. The safe and effective delivery of SBRT requires careful attention to tumor motion management, special dosimetric and planning challenges, and commissioning of dedicated equipment and quality assurance. This session will provide an overview of these important technical considerations as well as a survey of clinical outcomes reported based on the use of SBRT in the treatment of different tumor sites. Learning Objectives: 1. Describe available methods for motion management and the rational selection of planning margins 2. Discuss techniques for SBRT treatment planning and the impact of dose calculation algorithm 3. Describe key elements of commissioning, patient‐specific QA, and routine periodic machine performance QA 4. Review clinical observations reported after SBRT for lung, liver, pancreas, spine, head & neck, and prostate.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume37
Issue number6
DOIs
StatePublished - 2010

Fingerprint

Radiosurgery
Prostate
Pancreas
Neoplasms
Spine
Neck
Head
Learning
Equipment and Supplies
Lung
Liver
Therapeutics

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

WE‐D‐BRA‐01 : Stereotactic Body Radiotherapy (SBRT): Technical and Clinical Considerations. / Kavanagh, B.; Chetty, I. J.; Balter, J. M.; Solberg, T. D.

In: Medical Physics, Vol. 37, No. 6, 2010.

Research output: Contribution to journalArticle

Kavanagh, B. ; Chetty, I. J. ; Balter, J. M. ; Solberg, T. D. / WE‐D‐BRA‐01 : Stereotactic Body Radiotherapy (SBRT): Technical and Clinical Considerations. In: Medical Physics. 2010 ; Vol. 37, No. 6.
@article{00e680081f62448b993546af624516c8,
title = "WE‐D‐BRA‐01: Stereotactic Body Radiotherapy (SBRT): Technical and Clinical Considerations",
abstract = "Stereotactic Body Radiotherapy (SBRT) has now been applied clinically for more than a decade. The accumulation of published technical and clinical studies currently available has offered insights into both the efficacy and special concerns associated with the delivery of SBRT to different sites. The safe and effective delivery of SBRT requires careful attention to tumor motion management, special dosimetric and planning challenges, and commissioning of dedicated equipment and quality assurance. This session will provide an overview of these important technical considerations as well as a survey of clinical outcomes reported based on the use of SBRT in the treatment of different tumor sites. Learning Objectives: 1. Describe available methods for motion management and the rational selection of planning margins 2. Discuss techniques for SBRT treatment planning and the impact of dose calculation algorithm 3. Describe key elements of commissioning, patient‐specific QA, and routine periodic machine performance QA 4. Review clinical observations reported after SBRT for lung, liver, pancreas, spine, head & neck, and prostate.",
author = "B. Kavanagh and Chetty, {I. J.} and Balter, {J. M.} and Solberg, {T. D.}",
year = "2010",
doi = "10.1118/1.3469388",
language = "English (US)",
volume = "37",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - WE‐D‐BRA‐01

T2 - Stereotactic Body Radiotherapy (SBRT): Technical and Clinical Considerations

AU - Kavanagh, B.

AU - Chetty, I. J.

AU - Balter, J. M.

AU - Solberg, T. D.

PY - 2010

Y1 - 2010

N2 - Stereotactic Body Radiotherapy (SBRT) has now been applied clinically for more than a decade. The accumulation of published technical and clinical studies currently available has offered insights into both the efficacy and special concerns associated with the delivery of SBRT to different sites. The safe and effective delivery of SBRT requires careful attention to tumor motion management, special dosimetric and planning challenges, and commissioning of dedicated equipment and quality assurance. This session will provide an overview of these important technical considerations as well as a survey of clinical outcomes reported based on the use of SBRT in the treatment of different tumor sites. Learning Objectives: 1. Describe available methods for motion management and the rational selection of planning margins 2. Discuss techniques for SBRT treatment planning and the impact of dose calculation algorithm 3. Describe key elements of commissioning, patient‐specific QA, and routine periodic machine performance QA 4. Review clinical observations reported after SBRT for lung, liver, pancreas, spine, head & neck, and prostate.

AB - Stereotactic Body Radiotherapy (SBRT) has now been applied clinically for more than a decade. The accumulation of published technical and clinical studies currently available has offered insights into both the efficacy and special concerns associated with the delivery of SBRT to different sites. The safe and effective delivery of SBRT requires careful attention to tumor motion management, special dosimetric and planning challenges, and commissioning of dedicated equipment and quality assurance. This session will provide an overview of these important technical considerations as well as a survey of clinical outcomes reported based on the use of SBRT in the treatment of different tumor sites. Learning Objectives: 1. Describe available methods for motion management and the rational selection of planning margins 2. Discuss techniques for SBRT treatment planning and the impact of dose calculation algorithm 3. Describe key elements of commissioning, patient‐specific QA, and routine periodic machine performance QA 4. Review clinical observations reported after SBRT for lung, liver, pancreas, spine, head & neck, and prostate.

UR - http://www.scopus.com/inward/record.url?scp=85024781045&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024781045&partnerID=8YFLogxK

U2 - 10.1118/1.3469388

DO - 10.1118/1.3469388

M3 - Article

AN - SCOPUS:85024781045

VL - 37

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -